SI design values and US ratings
A design done in SI yields mass flow in kg/s. Equipment from US manufacturers is rated in pounds per hour, a combination that is standard on boiler nameplates, steam humidifier data sheets, burner specifications and production line brochures. To select a unit or check an offer you must convert both the mass unit and the time unit. This page performs that double conversion at once, with the factor 7,936.64144 lb/h per kg/s. It is useful for consultants working on projects with mixed teams, for plant engineers evaluating imported equipment and for anyone moving between metric calculations and US catalogs. A typical case is a design memo that gives the steam load as 1.1 kg/s while the quotation lists boilers by lb/h. Converting once, at the top of the comparison, keeps every later line in the same unit and avoids the common error of comparing a kg/h figure with a lb/h rating as if both were the same.
The combined factor
The international pound is exactly 0.45359237 kg, so 1 kg equals 2.20462262 lb. An hour is 3,600 s. Combining the two gives 2.20462262 × 3,600 = 7,936.64144 lb/h for each kg/s. The formula is lb/h = kg/s × 7,936.64144, and the reverse is kg/s = lb/h × 0.000125998, which comes from 0.45359237 ÷ 3,600. If you remember that 1 kg/s is about 8,000 lb/h, you can catch errors by estimation. A result 10 times larger or smaller than your estimate means a decimal slip somewhere in the entry or the unit menu. The reverse check also works: 8,000 lb/h is about 1.008 kg/s, and 80,000 lb/h is about 10.08 kg/s, so the default and its result are consistent when you divide by the same landmark.
What the default shows
Ten kilograms per second is 79,366.4 lb/h, so 79 thousand pounds of material every hour. That is the scale of a mid-size process steam boiler or a large food production line. For a quick consistency check, 10 kg/s is 36,000 kg/h, and 36,000 times 2.20462 gives the same 79,366. Using the default as a calibration point makes the other conversions easier to judge. When your number is smaller, for example 0.05 kg/s, the result of 396.83 lb/h is easier to read. A flow of 0.005 kg/s gives 39.68 lb/h, and 0.001 kg/s gives 7.94 lb/h, so each tenfold change in the input moves the decimal point by one place in the output with no other change.
A steam boiler rated in pounds per hour
A boiler listed at 10,000 lb/h of steam produces 1.26 kg/s, because 10,000 ÷ 7,936.64 = 1.26. Entering 1.26 kg/s returns 10,000.17 lb/h, a small difference that comes from rounding the input. In a project specified in SI, the steam demand is calculated in kg/s, and the offer from a US supplier shows the rating in lb/h. Matching the two lets you see that a 1.26 kg/s load fits a 10,000 lb/h boiler only with no margin, and that a margin of 20 percent needs a unit near 12,000 lb/h. The rating applies at stated conditions, such as feedwater temperature and pressure, so check the datasheet. Boiler ratings are also given in horsepower or in kW of output on some lists, and those figures are not mass flows, so confirm that the number you compare is steam in pounds per hour before you convert anything.
A snack production line
A food plant moving product at 0.5 kg/s processes 1,800 kg/h, which is 3,968.32 lb/h, a figure that fits a US line rated in pounds per hour. A smaller pilot line at 0.05 kg/s handles 396.83 lb/h, and one at 2 kg/s handles 15,873.28 lb/h. When plant data comes from a scale in kg/s and the equipment brochure lists capacity in lb/h, the page lets you test whether the line fits. Product conditions matter, because the capacity of a fryer, dryer or packer depends on the moisture, size and the product itself, which the supplier documentation covers. A line that dries a wetter product often runs well below its nameplate rate, so ask for the rating at the moisture and size of your own product and convert that number, not the brochure headline.
Fuel and burners
Burner capacity can be stated as a fuel mass flow, and a US datasheet might give lb/h while the design basis is in kg/s. A burner that must consume 0.05 kg/s of fuel needs a rating of at least 396.83 lb/h. Fuel flow also gives heat input when multiplied by the heating value. That step is outside this page, since the heating value varies by fuel and basis. Use the conversion to match the mass flow only, and apply the heating value from the supplier fuel analysis if you need energy. Burners are often fitted with a turndown range, and the rating applies at maximum firing, so a flow below the maximum may sit outside the stable range at the low end. Check the minimum stable rate in the burner manual before you choose a unit from a converted value.
Checking by estimation and round trip
Estimate with 8,000: 2 kg/s gives roughly 16,000 lb/h, and the page returns 15,873.28. Convert back to confirm: 15,873.28 lb/h entered with pounds per hour as the source and kilograms per second as the target returns 2 kg/s. If the round trip does not return the original, one of the menus is set wrongly. Keep about four significant figures in intermediate results and round only the final value to match the precision of the input, since design flows rarely carry more than three significant figures. Where a spreadsheet does the conversion, keep the factor 7,936.64144 in a named cell and refer to it in every formula, so a later correction touches one place only.
Words and symbols
Pounds per hour appears as lb/h, lb/hr, lbs/hr or pph. Kilograms per second is kg/s or kg·s⁻¹. The pound is a mass unit here, and the pound-force lbf is a different thing. A rating written as klb/h means thousands of pounds per hour, so 10 klb/h is 10,000 lb/h, and MMlb/h is millions. Confirm the multiplier on a data sheet, since the difference between lb/h and klb/h is a factor of 1,000. The same applies to the letter M, which means thousand in some older US notation and million in the SI, so MLB/h on an old drawing deserves a question to the supplier before you rely on it.
Boiler and burner process demand
The converter changes the unit of a mass flow. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not confirm that a boiler, burner or line meets the demand of your process.