Two ways to count the same charge

The coulomb is the SI unit of electric charge, and the kilocoulomb is a convenient multiple for amounts moved by batteries and electrochemical cells. The ampere hour is a non-SI unit that battery makers use for capacity, and it appears on car batteries, e-bike packs and chargers. A lab report may give the charge passed in an electrolysis experiment in kC, while a battery data sheet states ampere hours. This page connects the two. Enter the kilocoulombs and read the ampere hours, using the relation 1 Ah = 3,600 C, which follows directly from the definition of the ampere. People reach for this conversion when they read a bench power supply log, a battery tester printout or a textbook on electrochemistry, and need the result in the unit that appears on a battery label.

The factor of 1,000 over 3,600

One ampere hour equals 1 C/s times 3,600 s, which is 3,600 C or 3.6 kC. Dividing kilocoulombs by 3.6 therefore gives ampere hours, and the page does this as multiplication by 0.277777778. The default 10 kC returns 2.7778 Ah. The factor is exact, since both units come from definitions, though the decimal repeats. Going the other way, 1 Ah is 3.6 kC, and 1 mAh is 3.6 C. These anchors let you check any result: 36 kC should be 10 Ah, and 3.6 kC should be 1 Ah. A tester that reports 1,080 C after a short discharge has moved 1.08 kC, which is 0.3 Ah or 300 mAh. Dividing by 3.6 in your head and comparing with the page result is a fast way to confirm that the unit menus are set the way you intended.

Phone, power bank and car battery

A phone battery rated at 3,000 mAh holds 3 Ah, which is 10.8 kC. A power bank of 10,000 mAh holds 10 Ah, or 36 kC, although rated capacity at the cell voltage is not what you get at the 5 V output. A car battery of 60 Ah corresponds to 216 kC. These figures count charge and not energy, so a 3.7 V cell and a 12 V battery with the same Ah rating hold different energies. Multiply the charge in coulombs by the voltage to get joules, or the ampere hours by the voltage to get watt-hours, when you need an energy figure. A rated capacity is also measured under specified conditions, usually a stated discharge current and temperature, and a cell asked for more current than that delivers fewer ampere hours. A 3,000 mAh label is therefore a statement about a test and not a promise for every load, and the converted 10.8 kC inherits the same limitation.

Electroplating arithmetic

Faraday found that the mass deposited in electrolysis is proportional to the charge passed. Running 5 A for 2 hours passes 10 Ah, which is 36 kC. For copper with two electrons per ion and a molar mass of 63.546 g/mol, 36,000 C deposits 36,000 × 63.546 / (2 × 96,485) = 11.85 g at 100 percent current efficiency. Real plating baths deposit somewhat less because of side reactions, and the page gives only the charge conversion. The example shows why plating records may list charge in kC while the power supply display shows amperes and hours. Running the same bath at 2 A for 5 hours also passes 10 Ah, so the deposit is the same, a reminder that the product of current and time is what counts and not either factor alone. If the measured mass comes out lower than the theoretical 11.85 g, the ratio of the two is the current efficiency of the bath.

The Faraday constant in these units

The Faraday constant, the charge of one mole of electrons, is 96,485.33212 C/mol, an exact value since the 2019 SI redefinition fixed the elementary charge and the Avogadro constant. That is 96.48533 kC, or 26.8015 Ah. In plain terms, a current of 26.8 A for one hour moves one mole of electrons. This is a convenient anchor in electrochemistry and in battery chemistry, where the theoretical capacity of an electrode material is the Faraday constant divided by the molar mass per electron, then divided by 3.6 to express it in mAh per gram. The formula is capacity in mAh per gram = 26,801.5 divided by the molar mass per electron, with the molar mass in g/mol. For an electrode material with a molar mass of 100 g/mol per electron, that gives 268 mAh/g. The number is a ceiling from chemistry and real electrodes deliver less, but it shows how kilocoulomb and ampere hour figures connect to materials research.

From ampere hours to kilocoulombs

To convert the other way, choose ampere hours as the source and kilocoulombs as the target. The page multiplies by 3.6. A 20 Ah battery is 72 kC, and 0.5 Ah is 1.8 kC. For small cells, converting through milliampere hours is also supported, with 2,500 mAh equal to 2.5 Ah and 9 kC. The reverse direction helps when a battery capacity has to be entered in a simulation or a test system that works in coulombs, and when comparing the charge delivered by a discharge test with the cell rating.

Coulomb counting in battery monitors

Battery management chips estimate the state of charge by integrating current over time, a method called coulomb counting. The integral is in coulombs or in ampere hours depending on the design. If a monitor reports 5.4 kC removed from a 10 Ah pack, that is 1.5 Ah, or 15 percent of the capacity. Cell aging, temperature and measurement drift mean that the capacity itself changes, so monitors recalibrate against the voltage at full and empty. The conversion on this page supplies the unit link, and the monitor documentation tells you what the number represents. A steady 2 A for one hour gives 7,200 C, which is 7.2 kC or 2 Ah, and checking one hour of a log against that arithmetic shows whether a monitor integrates in coulombs or ampere hours.

Charge is not energy

It is easy to treat ampere hours as if they measured the stored energy of a battery. They count charge. Two batteries with the same Ah rating can store very different energies if their voltages differ, and the same battery delivers a different amount of charge at different loads. A 12 V, 60 Ah battery holds 720 Wh, which is 2.592 MJ, while a 3.7 V, 60 Ah pack holds 222 Wh. Convert to watt-hours or joules only after taking the voltage into account. This page deliberately does no voltage step, because the input is a charge and the output is a charge.

Battery runtime and charging time

The page rescales a charge from one unit to another. It does not calculate battery runtime, charging time, state of charge or deposition mass, and it makes no assessment of electrical installations or equipment ratings. Those calculations need voltage, current, efficiency and chemistry that the converter does not have. Treat the result as the same quantity of charge written in the unit your document uses.