A gas bill on one side, a power bill on the other
Households and building managers often hold two energy statements in different units. Natural gas and district heat are billed in gigajoules in Canada and in parts of Europe, while the electricity bill gives kilowatt-hours. Anyone weighing a heat pump against a furnace, or checking a total energy budget for a house, needs both on the same scale. This page converts the gigajoule figure to kilowatt-hours so the two can be added or compared. The conversion is unit arithmetic. It tells you how much energy the number represents and nothing about how much of it reaches the rooms, which depends on the equipment that burns the fuel or runs the compressor.
Where 277.78 comes from
The kilowatt-hour is one kilowatt sustained for one hour. A kilowatt is 1,000 joules per second and an hour is 3,600 seconds, so a kilowatt-hour is 3,600,000 joules, which NIST SP 811 lists as 3.6 × 10^6 J. Dividing one gigajoule, 10^9 joules, by that figure gives 277.777777778 kWh, a repeating decimal cut at twelve digits. The default 10 GJ then gives 2,777.777777778 kWh. The shortcut to remember is that 3.6 GJ equals 1,000 kWh. Dividing any gigajoule value by 0.0036 gives the same result and avoids typing the long factor.
Sizing a household year
A convenient anchor is 36 GJ, which equals 10,000 kWh, a round figure that is in the range of annual electricity use for many homes. A family that uses 85 GJ of gas in a heating season has used about 23,611 kWh of heat energy, which is more than twice that anchor. A smaller condominium using 18 GJ has used 5,000 kWh. These numbers are arithmetic illustrations, not statements about typical homes, and real usage depends on climate, floor area and insulation. The page makes the comparison possible by putting both figures on one scale, and it leaves the judgment to the reader. For a monthly view, divide the annual gigajoule figure by 12 before converting, or convert first and divide afterward. Both orders give the same answer, because the factor is a constant multiplier. Seasonal swings in heating mean the monthly figure is far from the annual average in winter and summer.
Thermal kilowatt-hours versus electrical ones
A kilowatt-hour of heat and a kilowatt-hour of electricity are the same amount of energy, yet they are not interchangeable in cost or use. A gas furnace with an efficiency of 95 percent delivers 0.95 kWh of heat for each kWh of gas energy burned. A heat pump can deliver more than one kWh of heat per kWh of electricity, since it moves heat and does not create it. For that reason, converting a gas total from gigajoules to kWh is only the first step in a fair comparison. This page covers that first step. Efficiency, tariffs and delivery costs have to come from your own equipment sheets and rate schedules.
Going from kWh back to gigajoules
Choose kilowatt-hours as the source and gigajoules as the target to multiply by 0.0036. A monthly electricity reading of 500 kWh returns 1.8 GJ, and 2,777.78 kWh returns about 10 GJ. The reverse direction helps when you want to express electricity in the units of a gas utility so that one chart shows both. Because the factor 0.0036 is exact by definition, the reverse conversion is free of approximation, while the forward factor has the long repeating decimal described earlier. Both directions agree to far more digits than any meter provides. A quick mental check is that 100 kWh is 0.36 GJ, so a reading of 3,000 kWh should land near 10.8 GJ, and any result far from that points to a slipped decimal.
Precision and the repeating decimal
The factor 277.777777778 is rounded at the twelfth significant digit, so its error is far below one part in a trillion. For billing, round the answer to the precision of your meter. A gas total of 12.4 GJ becomes 3,444.44 kWh, and two decimals are plenty. Do not round the factor to 277.8 when the figures are large, because the shortfall adds up. With 10 GJ, using 277.8 gives 2,778 kWh against 2,777.78, a difference of 0.22 kWh. That is small here, but with 1,000 GJ the same shortcut shifts the answer by 22 kWh, which can show up as a mismatch against a supplier statement.
Megawatt-hours and the middle step
Larger facilities, campuses and industrial sites report in megawatt-hours, and one gigajoule is 0.27777778 MWh. A plant using 36 GJ has used 10 MWh. If your report already carries MWh, convert once from gigajoules and move the decimal point by three places for kWh, instead of chaining several conversions. Every extra step is a place to introduce a typing error. The relation 1 MWh = 3.6 GJ is also easy to memorize and serves as a quick check against any page result you want to verify by hand.
Converting a monthly gas reading step by step
Gas meters in some regions report cubic meters, and the utility converts to gigajoules on the bill using a heating value. Suppose a statement shows 4.6 GJ for one winter month. Multiply by 277.777777778 to get about 1,277.78 kWh. If the same household used 620 kWh of electricity that month, the combined total is about 1,897.78 kWh, which can then be compared with the same month a year earlier. Work with the bill figure in gigajoules and avoid converting from cubic meters yourself unless you have the heating value printed on the statement, since that value changes with the gas composition. Keep the converted figures to two decimals, and keep a note of which month and which meter each number came from.
Generation and transmission losses not counted
The converter reports the same quantity of energy in another unit. It does not account for losses in generation, transmission or combustion, it does not convert between fuel types, and it does not apply tariffs, taxes or emissions factors. If you need cost or carbon figures, take the kilowatt-hour result as the input and apply the supplier rate or the factor published by the relevant agency. Check that your source uses the same energy basis, since gas utilities may state higher or lower heating values, and the choice changes the total by several percent. If two bills disagree after conversion, compare the billing periods and the heating value basis before suspecting the arithmetic, because those are the usual causes of a gap.