Frequency in two languages

Radio engineers talk about frequency in megahertz, while the equations they use are written in angular frequency. The sine wave of a signal is written sin(ωt), where ω is the angular frequency in radians per second, and the circuit formulas for inductors, capacitors and transmission lines all use ω rather than f. A datasheet or a band plan gives the frequency in megahertz, so every calculation begins with a conversion. This page does that conversion in a single step. Enter the frequency in megahertz, and the result is ω in radians per second. The calculation is exact apart from the value of π, which the engine represents as a double-precision number with about 16 significant digits. That is far more than any physical measurement of a radio frequency needs, so the result can be used directly in further work.

The formula behind the page

The two steps are simple. One megahertz is 1,000,000 cycles per second. Each cycle sweeps an angle of 2π radians, which is 6.283185307179586. Multiplying the two gives 6,283,185.307 radians per second per megahertz, which the page rounds to 6283185.30718 in its formula line. For the default input of 10 MHz, the result is 62,831,853.07 rad/s. A frequency of 1 MHz is 6,283,185.3 rad/s, 13.56 MHz is 85,199,992.8 rad/s and 100 MHz is 628,318,530.7 rad/s. The relation is linear, so doubling the frequency doubles the angular frequency. The radian is the SI unit of plane angle, defined as the angle subtended by an arc equal in length to the radius, and the SI treats it as a dimensionless quantity, which is why radians per second reduce to inverse seconds.

Why radians appear in the equations

The radian is the natural unit of angle in calculus. The derivative of sin(x) is cos(x) only when x is in radians, and that is why oscillation equations use them. A signal at 10 MHz completes one cycle in 100 nanoseconds. Over that time, the phase advances through 2π radians, or 360 degrees, so the angular frequency is 2π divided by 100 ns, which equals 62.83 million radians per second. Using ω avoids carrying a factor of 2π through every formula. The reactance of an inductor is ωL, the reactance of a capacitor is 1 divided by ωC, and the resonant frequency of an LC circuit is 1 divided by the square root of LC. If you wrote the same formulas in terms of f, each would contain a 2π, and the expressions would be clumsier.

Do not confuse hertz with radians per second

A common error is to enter a frequency in hertz where a formula expects radians per second, or the reverse. The two differ by a factor of 6.28, which is large enough to ruin a design but small enough to look plausible at a glance. A 1 MHz signal has ω of about 6.28 million rad/s, and treating 1,000,000 as ω would suggest a signal near 159 kHz. Check the unit of any value that goes into a reactance or impedance calculation. Symbols help: f is generally in hertz and ω in radians per second, but some texts use ν for frequency and some use ω loosely for either. The converter labels its output as rad/s, which leaves no room for doubt. When in doubt, compute one reactance both ways and see which result is consistent with the frequency you intended.

Reactance of an inductor and a capacitor

Two short calculations show the page in use. An inductor of 10 microhenries at 1 MHz has a reactance of ωL, which is 6,283,185 times 0.00001, or 62.83 ohms. Raise the frequency to 10 MHz and the reactance rises to 628.3 ohms. A capacitor of 100 picofarads at 1 MHz has a reactance of 1 divided by ωC, which is 1 divided by 6,283,185 times 10 to the minus tenth, or 1,591.5 ohms. At 10 MHz it falls to 159.15 ohms. Inductor reactance grows with frequency and capacitor reactance falls. Getting ω from the converter first removes a source of slips, because the number of zeros in a megahertz value is easy to get wrong when you key it into a calculator. The component values are illustrative.

Finding the resonant frequency

Combine the two components from the previous example into an LC circuit. The resonant angular frequency is 1 divided by the square root of the product of L and C. With 10 microhenries and 100 picofarads, LC is 10 to the minus fifth times 10 to the minus tenth, which is 10 to the minus fifteenth. The square root is 3.162 times 10 to the minus eighth, and its reciprocal is 31,622,777 rad/s. To express that as a conventional frequency, divide by 6,283,185, which gives about 5.033 MHz. The page can run in both directions, since it supports radians per second as a source unit as well. Entering 5.0329 MHz returns about 31.62 million rad/s, a quick way to confirm the arithmetic. Real components have tolerances and parasitic effects, so the measured resonance will differ from the ideal value.

Phase advance over a short time

Angular frequency also tells you how far a signal advances in phase during a given interval. Phase equals ω times t. At 1 MHz, ω is 6.283 million rad/s, so in 100 nanoseconds the phase moves by 0.6283 radians, which is 36 degrees, one tenth of a cycle. Timing errors in radio systems translate into phase errors in exactly this way. A delay of 5 nanoseconds at 100 MHz is half a cycle, 180 degrees, since the period is 10 ns, which is enough to turn constructive interference into destructive. Cable length differences in antenna arrays and clock distribution designs are specified in terms of phase for this reason. The converter gives ω, and multiplication by the delay gives the phase in radians, which can be converted to degrees by multiplying by 180 divided by π.

Rotating phasors and the period

Angular frequency has a geometric meaning that helps with intuition. A complex exponential written as e to the power jωt is a point moving around the unit circle, and ω is how many radians it sweeps each second. At 10 MHz that point goes around 10 million times per second, which is 62.83 million radians. The period of the signal is 2π divided by ω, so it recovers the familiar value of 100 nanoseconds. Alternating-current analysis with phasors uses this picture: a voltage and a current become two arrows at a fixed angle to each other, rotating together, and only their angle difference matters. Inductors turn the current arrow 90 degrees behind the voltage, and capacitors turn it 90 degrees ahead. The converter provides ω for the exponent, and the rest of the analysis follows from the circuit values.

Skin effect and frequency

At higher frequencies, current in a conductor crowds toward the surface. The skin depth depends on ω, the permeability and the conductivity of the material. For copper it is about 66 micrometers at 1 MHz, and it shrinks with the square root of frequency, so at 10 MHz it is about 21 micrometers and at 100 MHz about 6.6 micrometers. The formula uses ω in the denominator under a square root, which is why a conversion to rad/s comes first. Skin effect raises the resistance of wires and traces at radio frequencies, and it is the reason plating and surface finish matter more on RF conductors than on power wiring. The numbers here are approximate values for room temperature, and the exact figure depends on the alloy and the conductivity used.

Sampled signals and normalized frequency

Digital signal processing uses angular frequency in a different way. A tone is described by its frequency in radians per sample, equal to 2π times the tone frequency divided by the sampling rate. A 1 MHz tone sampled at 10 million samples per second has a normalized frequency of 2π times 0.1, or 0.6283 radians per sample. The Nyquist limit is π radians per sample, so frequencies above half the sample rate fold back. The page gives radians per second, and dividing by the sample rate in samples per second yields the normalized value. A mismatch between the two forms is a classic source of bugs in filter code. When you read a filter coefficient formula that includes ω0, check whether it means radians per second or radians per sample before inserting a number.

Familiar frequencies in rad/s

A few reference values are useful for checking results. The standard AM radio intermediate frequency of 455 kHz, or 0.455 MHz, is 2,858,849 rad/s. The 13.56 MHz NFC and RFID frequency is 85.2 million rad/s. An FM station at 100 MHz is 628.3 million rad/s. The 2.4 GHz Wi-Fi band, entered as 2,400 MHz, comes to about 15.08 billion rad/s. These large numbers explain why engineers often prefer to keep megahertz in the notes and convert only when substituting into a formula. Another habit is to use the product ωL or 1/ωC with the components in microhenries and picofarads, so that the powers of ten cancel more easily. The converter handles the multiplication, and you keep track of the component prefixes.

Accuracy and limits

The conversion is a definition combined with the value of π, so its only uncertainty is in the input. A frequency measured to six digits gives an angular frequency to six digits. The page shows more digits than that, and you should round the result to match your input. It does not compute phase, impedance, resonance or wavelength, and it does not know whether the frequency you enter is allowed on air. To go from radians per second back to megahertz, swap the units and enter the angular value. Component choices and compliance checks belong to the manufacturer's documents and the standards that govern your product, and this page covers only the unit step.