Frequency counts cycles per time under the stated cycle convention.

Measurement basis

Hertz is inverse seconds for a cycle rate. Angular frequency describes the same cycling with an angular convention and needs its 2π relationship retained.

Definition conventions

One revolution or beat counts as one cycle. Divide rad/s by 2π to obtain cycles per second.

Conversion method

Use the prefix and time scales for cycle units, and include 2π when moving between cycle and angular conventions.

Choose the conversion direction

Identify whether the source is a cycle rate or angular rate before selecting the target.

What frequency measures

Frequency is the number of occurrences of a repeating event per unit time. For a periodic signal, a rotation or an oscillation, it is the reciprocal of the period: f = 1/T, so a signal with a period of 2 ms has a frequency of 500 Hz. The SI unit is the hertz, symbol Hz, defined as one cycle per second, or s^-1. The unit honors Heinrich Hertz, who demonstrated radio waves in the 1880s, and the General Conference on Weights and Measures adopted the name in 1960. In the 2019 SI, the second is defined by fixing the cesium-133 hyperfine transition frequency at exactly 9,192,631,770 Hz, so the hertz is tied to the same atomic reference as time. Frequency covers a very wide range, from mains power at 50 or 60 Hz to radio, microwave and optical frequencies in the terahertz and beyond.

The cycle convention

The hertz counts cycles, so the convention for what counts as one cycle must be known. For an alternating current, one cycle is one full sine wave. For a rotating shaft, one cycle is one revolution. For a heartbeat or a metronome, one cycle is one beat. The hertz does not carry a name for the thing being counted, which is why the dimension s^-1 can describe cycles, revolutions or beats. When a source quotes 1.2 Hz for a heart rate, it means 1.2 beats per second, equal to 72 beats per minute. A frequency that does not state its cycle can lead to errors by a factor of two, for example when a signal has a fundamental and a second harmonic, or when a full-wave rectifier doubles the apparent ripple frequency of a 60 Hz supply to 120 Hz.

Prefixes and the supported scales

Frequency units are mostly prefix scales of the hertz. One kilohertz (kHz) is 1,000 Hz, one megahertz (MHz) is 1,000,000 Hz, one gigahertz (GHz) is 10^9 Hz and one terahertz (THz) is 10^12 Hz. Below the hertz, millihertz (mHz) is 0.001 Hz, which describes slow phenomena such as ocean waves or the oscillation of a slow structure. Conversions among the prefixed forms are exact powers of 10. Reading across scales takes care with capitalization: mHz is a thousandth of a hertz, while MHz is a million hertz, a difference of nine orders of magnitude. Typical anchors help with sanity checks: audio is roughly 20 Hz to 20 kHz for human hearing, AM broadcast is in the hundreds of kilohertz, FM in the tens of megahertz, and Wi-Fi in the gigahertz range.

Angular frequency and the factor of 2π

Angular frequency, usually written ω, counts radians per second, and a full cycle is 2π radians. The relation is ω = 2πf. A 50 Hz supply has an angular frequency of 314.159 rad/s, and a 60 Hz supply has 376.991 rad/s. Going the other way, divide rad/s by 2π: a motor shaft turning at 100 rad/s completes 100/6.283185 = 15.915 revolutions per second. The two values have the same dimension but different numerical size, and a value in rad/s is not interchangeable with a value in hertz. A prefix-only conversion that skips the 2π factor produces an error of about 6.28 times. Because π is irrational, any numerical factor is truncated at some number of digits, so the result carries the finite precision of the stored constant. Keep the label rad/s attached so the 2π step is not dropped when a value moves between documents.

Revolutions per minute and beats per minute

Rotating machinery and music use per-minute cycle rates. One revolution per minute equals 1/60 Hz, or 0.016667 Hz. A motor at 1,800 rpm turns at 30 Hz, and one at 3,000 rpm turns at 50 Hz, which matches the mains frequency in 50 Hz regions for a two-pole synchronous speed. A metronome at 120 beats per minute ticks at 2 Hz. A hard disk spinning at 7,200 rpm completes 120 revolutions per second. These conversions divide by 60 and keep the cycle convention intact. Care is needed with per-minute rates that count different things. In a four-stroke engine each cylinder fires once every two crankshaft revolutions, so the firing frequency of one cylinder is half the rotation frequency. State the thing being counted next to the rate before converting to hertz.

Frequency, period and wavelength

Frequency links to period and to wavelength for waves. The period is T = 1/f, so 1 kHz has a period of 1 ms, 1 MHz has 1 µs, and 1 GHz has 1 ns. For electromagnetic waves in vacuum, wavelength is λ = c/f, where c = 299,792,458 m/s exactly. A 100 MHz signal has a wavelength of 2.998 m, and a 2.4 GHz signal has 12.49 cm. For sound in air at 20 °C, the speed is about 343 m/s, so a 1 kHz tone has a wavelength of about 34.3 cm. The frequency stays the same when a wave crosses between media, but speed and wavelength change. That makes frequency the property to record, while wavelength depends on the medium. A conversion between frequency units needs none of these relations, but a design question often does, so it helps to know that the hertz connects to both time and length scales.

Hertz and becquerel share a dimension

The SI Brochure lists the becquerel (Bq), the unit of activity of a radioactive source, as one disintegration per second, giving it the dimension s^-1 like the hertz. The two are not interchangeable. The hertz is reserved for periodic phenomena, and the becquerel is used for random events counted over time. A source with an activity of 500 Bq is not a 500 Hz signal, and a 500 Hz tone is not a radioactive source. Both share the same unit in base terms, which is why unit-conversion software separates them by quantity. A count rate or activity belongs in a different quantity group from cycle-based frequency. Mixing them in a spreadsheet only because the base dimension matches produces numbers that look valid and mean nothing, so keep the quantity name with the unit.

Everyday anchors for sanity checks

A few familiar frequencies make it easy to catch a misplaced prefix. Concert pitch for the note A above middle C is standardized at 440 Hz in ISO 16. Human hearing is usually quoted as roughly 20 Hz to 20 kHz, with the upper limit falling with age. Mains electricity runs at 50 Hz in Europe and many other regions and at 60 Hz in North America, and full-wave rectified ripple appears at twice those values. Wi-Fi uses bands near 2.4 GHz and 5 GHz, microwave ovens operate around 2.45 GHz, and visible light spans roughly 430 to 750 THz. The SI definition of the candela uses a monochromatic radiation of 540 × 10^12 Hz, which is 540 THz, in the green part of the spectrum. If a conversion makes a household mains supply come out at 50 MHz or a Wi-Fi band at 2.4 kHz, the prefix has slipped by a factor of a thousand or more, and a quick look at these anchors exposes it.

Sampling rate and the Nyquist limit

Digital systems quote a sampling rate in samples per second, often written in hertz, and it is easy to confuse with the frequency of the signal being sampled. The Nyquist criterion says that a band-limited signal can be reconstructed when the sampling rate exceeds twice its highest frequency component. Audio with content up to 20 kHz therefore needs a sampling rate above 40 kHz, which is why compact disc audio uses 44,100 samples per second and professional video and film audio often use 48,000. Sampling at 44.1 kHz does not mean the system records a 44.1 kHz tone. A component above half the sampling rate folds back into the band as an alias, which is why converters include an anti-aliasing filter before sampling. A unit conversion treats both numbers as plain frequencies, so the notes should say whether a value describes the signal, the sampling clock or the filter cutoff.

A worked set of conversions

Take a radio at 98.1 MHz. In hertz that is 98,100,000 Hz, in kilohertz 98,100 kHz and in gigahertz 0.0981 GHz. The period is 1/98,100,000 s, about 10.19 ns, and the wavelength is 299,792,458 divided by 98,100,000, about 3.056 m. Now a mechanical example: a fan at 1,200 rpm has f = 1,200/60 = 20 Hz, and its angular frequency is 2π × 20 = 125.66 rad/s. A third case, a 440 Hz concert pitch tone, is 0.44 kHz or 440,000 mHz, with a period of 2.27 ms. These examples use illustrative values and cover prefix scaling, a per-minute rate, an angular value and a period, which are the four most common frequency tasks. For each, the first step is to identify which convention the source uses, and the second is to apply the matching factor and keep the result at the precision of the input.

Precision and traps in frequency data

Frequency measurements can be extremely precise, since frequency counters and atomic references measure to many digits. A value like 10.000000 MHz from a crystal oscillator is nominal, and the actual frequency differs by an amount given in parts per million, so a 25 ppm oscillator at 4 MHz may be off by up to 100 Hz. Retain the source precision in conversions and avoid reporting extra digits. Another trap is a rounded display: 59.9 Hz and 60.0 Hz are meaningfully different for a grid operator, though the difference is small compared with the nominal value. Finally, keep the prefix with the number when copying: 0.5 kHz and 500 Hz are the same value, but a table that mixes them invites misreads.

Precision and checking

  • Retain the cycle definition in the source.
  • A π-based factor has finite numerical precision.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Choose a unit definition

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.