Measurement basis
A hertz represents one cycle per second.
Definition conventions
One revolution or beat counts as one cycle. Divide rad/s by 2π to obtain cycles per second.
Conversion method
Keep a Hz value unchanged for the reference column. Divide by another frequency factor to change its notation.
Reference equivalent of Hz
1 Hz = approximately 1 Hz.
Recorded scale factors: 1 for Hz; 1 for Hz.
Worked example
Known input: 10 Hz. Reference equivalent: 10 Hz. The return conversion gives approximately 10 Hz.
The worked frequency already uses the reference scale.
Common reference values
| Input (Hz) | Reference equivalent (Hz) |
|---|---|
| 1 | 1 |
| 5 | 5 |
| 10 | 10 |
| 25 | 25 |
| 50 | 50 |
| 100 | 100 |
Compare one Hz with other units
| Target unit | Equivalent of 1 Hz | Definition guide |
|---|---|---|
| khz (kHz) | 0.001 | Read definition |
| mhz (MHz) | 0.000001 | Read definition |
| ghz (GHz) | 1e-9 | Read definition |
| rpm (rpm) | 60 | Read definition |
| radians per second (rad/s) | 6.28318530718 | Read definition |
| Terahertz (THz) | 1e-12 | Read definition |
One cycle per second
The hertz is the SI derived unit of frequency and is defined as one reciprocal second, 1 Hz = 1 s⁻¹. It counts how many times a periodic event repeats each second. The unit is named for Heinrich Hertz, the German physicist who demonstrated electromagnetic waves in the 1880s, and the General Conference on Weights and Measures adopted the name in 1960, replacing the older phrase cycles per second. The symbol is Hz, with a capital H because it comes from a person's name, and the unit itself is written in lower case, as in 50 hertz. The page title uses lower case hz only as a text label. Every SI second today is defined through a frequency: exactly 9,192,631,770 hertz is the caesium-133 hyperfine transition frequency that fixes the second.
What exactly gets counted
The hertz counts cycles, so you must decide what a cycle is before comparing two numbers. A rotating shaft completes one cycle per revolution, which links hertz to revolutions per minute: 1 Hz equals 60 rpm, and 3,000 rpm is 50 Hz. A heart beating at 72 beats per minute runs at 1.2 Hz. Angular frequency in radians per second counts radians of phase instead, and one cycle is 2π radians, so 1 Hz is 6.28318530718 rad/s and 1 rad/s is 0.159154943092 Hz. A physics formula that writes ω = 2πf uses the angular quantity, while a data sheet that says 50 Hz uses cycles. Mixing the two produces an error of a factor of about 6.28, which is the most common conversion mistake with this unit. Spinning machinery adds a third form: a flywheel at 1,200 rpm turns at 20 Hz, which is 125.66 rad/s, so one physical speed can appear as three different numbers.
Mains frequency and rotating machines
Power grids run at a fixed nominal frequency, 50 Hz in most of Europe, Asia and Africa and 60 Hz in North America and parts of other regions. The number sets the speed of synchronous machines: a two-pole generator at 50 Hz turns at 3,000 rpm and at 60 Hz it turns at 3,600 rpm. Grid operators keep the frequency within narrow bands, because a shortfall of generation slows every synchronous generator and shows up as a drop in frequency. Appliances designed for one standard may run slower, hotter or not at all on the other. A clock motor or a transformer rated for 60 Hz on a 50 Hz supply can overheat, so the nameplate frequency deserves as much attention as the voltage.
Sound and music
Pitch corresponds to frequency, and the audible range for young listeners is commonly given as about 20 Hz to 20,000 Hz, narrowing with age. The international standard concert pitch A4 is 440 Hz. Each octave doubles the frequency, so A5 is 880 Hz and A3 is 220 Hz, and each equal-tempered semitone multiplies it by about 1.0595, the twelfth root of two. Frequency ratios therefore describe musical intervals: a perfect fifth is close to 3:2, so a tone a fifth above 440 Hz lies near 660 Hz. Bass guitar strings sit near 41 Hz for the lowest E, and human speech carries most of its energy between roughly 100 Hz and 4,000 Hz. A frequency of 440 Hz has a period of 2.27 milliseconds, the reciprocal. Sound travels at roughly 343 m/s in air at 20 °C, so the wavelength of a 440 Hz tone is about 0.78 m, found by dividing speed by frequency.
Display refresh, sampling and clock rates
Digital systems quote hertz for anything that repeats at regular intervals. A 60 Hz display refreshes 60 times each second, giving a period of 16.67 ms, and a 144 Hz display refreshes every 6.94 ms. Audio sampled at 44,100 Hz, the compact disc rate, can represent frequencies up to half the sampling rate, 22,050 Hz, according to the Nyquist theorem. Processors are rated in gigahertz, where 1 GHz is 10⁹ Hz, so a 3.5 GHz clock ticks once every 0.2857 nanoseconds. Refresh rate and frame rate are separate quantities, though: a video file at 24 frames per second shown on a 60 Hz screen needs some frames repeated. Each of these uses a count per second, so the conversion is always against seconds.
Radio and wave frequencies
The product of frequency and wavelength is the speed of the wave, which for radio is the speed of light, 299,792,458 meters per second. A station at 100 MHz therefore has a wavelength of about 2.998 m, and a 2.4 GHz Wi-Fi channel has a wavelength near 12.5 cm. FM broadcasting occupies roughly 87.5 to 108 MHz in much of the world, with regional variations. Frequency allocations are managed nationally and coordinated through the International Telecommunication Union. Lower frequencies carry farther around the horizon, and higher frequencies carry more bandwidth but behave more like beams. The hertz scale runs from millihertz seismic and ocean oscillations through radio bands to petahertz for visible light, near 5 × 10¹⁴ Hz for green light.
Prefixes and conversions
Because hertz values span many orders of magnitude, prefixes do the work. One kilohertz is 1,000 Hz, one megahertz is 10⁶ Hz, one gigahertz is 10⁹ Hz and one terahertz is 10¹² Hz. Going down, one millihertz is 0.001 Hz and describes slow processes such as a 16.7 minute oscillation, which is about 1 mHz. The converter on this site covers hertz, kilohertz, megahertz, gigahertz, terahertz, revolutions per minute, beats per minute and radians per second. Convert 2,400 MHz to GHz and the result is 2.4 GHz. Convert 90 rpm to hertz and the answer is 1.5 Hz. Whatever the unit, write the prefix with the correct capital: kHz has a lowercase k, while MHz and GHz use capitals.
Hertz and becquerel share a dimension
The SI Brochure notes that the hertz and the becquerel are both expressed as reciprocal seconds, but the two quantities are different. Hertz is reserved for periodic phenomena, where one cycle repeats at regular intervals. The becquerel measures random nuclear decays per second, an average rate of events with no cycle. A source emitting 5,000 decays per second is 5,000 Bq, not 5 kHz. The same care applies to other per-second quantities. Rotational speed in revolutions per second is a frequency, while a flow of items per second is a rate. If the thing you are counting does not repeat in a cycle, use the specific unit or write per second explicitly rather than reaching for the hertz.
Precision and checking
- Keep source frequency precision.
- Retain the cyclic-frequency meaning.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Frequency converter
- Hz to khz converter
- Hz to mhz converter
- Hz to ghz converter
- Hz to rpm converter
- Hz to radians per second converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.
Sources
- NIST / BIPM: NIST: unit conversion factors ↗ · 2026-10-08