Two flow units in one American specification

American drawings and equipment lists mix gallons per minute for liquids with cubic feet per minute for air and sometimes for water. A pool pump is rated in gpm and a dehumidifier or fan in cfm, and a specification that uses both needs one unit. The default of 10 US gallons per minute returns 1.33681 cubic feet per minute. The page converts the volume rate of a liquid. It does not turn water flow into an air flow, and the density and compressibility of gases make cfm of air a different kind of figure from cfm of water.

The factor from gallon and foot definitions

A US liquid gallon is 3.785411784 liters, defined as 231 cubic inches. A cubic foot is 28.316846592 liters, from the international foot of 0.3048 meter. The ratio is 0.133681, so cfm = gpm × 0.133681. Inverted, a cubic foot holds 7.48052 US gallons. Remembering 7.48 gives a quick check: 10 gpm divided by 7.48 is 1.337 cfm, matching the page. A result near 10 means no conversion occurred, and one near 75 means a multiplication by 7.48 instead of a division. The factor is exact to the digits shown, since both inputs are definitions.

Pool pumps and filter flows

A pool pump rated at 60 US gallons per minute moves 8.02 cubic feet per minute. A filter or heater data sheet may list a maximum flow in either unit, and the page lets you check that the pump does not exceed it. A heater that accepts up to 80 gallons per minute would be limited to about 10.7 cubic feet per minute. These flows are illustrative. The rating of a pump is stated at a specific head, and the flow in a real system depends on the pipe and the filter resistance, so look at the curve before judging whether a pump suits a heater. Many heaters also state a minimum flow, and a pump that is too small can be as much of a problem as one that is too large.

Water weight as a plausibility check

Water weighs about 8.34 pounds per US gallon, so 10 gallons per minute carries roughly 83.4 pounds of water each minute. In cubic feet, the 1.3368 cubic feet per minute multiplied by about 62.4 pounds per cubic foot agrees with that figure. This check helps when a stream is described in one unit and its weight in another, for example the load on a drain line or a tank scale. The page does not convert mass, and the density of water changes with temperature, but the rule of 8.34 pounds per gallon is enough for a rough check of the flow you typed. A flow of 60 gallons per minute carries about 500 pounds of water every minute, which is a useful picture of what a drain, a hose or a support has to handle.

Velocity in a one-inch pipe

A flow of 10 gallons per minute is 0.0222801 cubic feet per second. A nominal one-inch Schedule 40 pipe has an inside diameter of 1.049 inches and a flow area of about 0.0060 square feet, so the average velocity is about 3.7 feet per second. Designers keep velocity within limits to control noise and pressure loss, and the limits depend on material and use, so look them up in the guidance for your pipe and application. The calculation shows why the conversion matters: velocity needs flow in cubic feet per second and area in square feet. This page converts the flow unit. Pipe sizing needs the actual inside diameter and the rules of your project.

From cubic feet per minute back to gallons

Select cubic feet per minute as the source and US gallons per minute as the target to reverse the conversion. A flow of 5 cfm equals 37.4 gallons per minute, and 1 cfm equals 7.48. Process and condensate equipment sometimes lists water flow in cfm, and the plumber works in gpm, so the reverse step comes up often when a drawing from one trade is read by another. The relation is linear, so a table can be filled from one factor. If you read a value like 0.5 cfm on a datasheet and the pump is rated in gpm, 0.5 times 7.48 gives 3.74 gpm. Round to the number of digits the original figure supports. A datasheet value of 0.5 cfm may itself be rounded, so avoid presenting 3.74 gpm as if it were known to three digits.

Imperial gallons give a larger flow

The same ten gallons per minute written with imperial gallons is 1.60544 cubic feet per minute, about 20 percent more than 1.33681 for US gallons. UK equipment data may be in imperial gallons, and a data sheet that says only gpm does not say which one it uses. The page has separate source options for US and imperial gallons per minute. If you compare a UK pump with an American filter, convert the pump from imperial gallons, not from US gallons. A liters per minute figure on the same sheet settles the question without guessing.

Reading small flows and rounding

A condensate pump that moves 0.5 gallons per minute passes only 0.0668 cubic feet per minute, and a figure like that needs three significant digits to be useful. Rounding to 0.07 would introduce an error of about 5 percent. For larger flows, one decimal is usually enough. Keep the unrounded value in a spreadsheet and round only the display. When comparing a pump with a limit, use unrounded numbers. A pump at 59.9 gallons per minute is 8.007 cubic feet per minute, which is just under 8.0 by a small margin that rounding to 8 would erase.

Sizing a pump takes a curve and a code

A unit conversion cannot judge whether a pump is the right size or whether a system meets code. Flow depends on head, pipe diameter, fluid and temperature, and these come from the equipment curve and the design standards. For heating, pool and process systems, follow the manufacturer instructions and the applicable rules, and ask a qualified person when safety is involved. The page provides a consistent change of unit based on the fixed definitions of the US gallon and the foot, so the same flow always gives the same cubic feet per minute. Write both the gpm and the cfm value in your drawing notes so a reviewer sees the conversion that was made.