Cubic feet and gallons in the same US workflow
US plumbers, irrigation designers and pump buyers talk in gallons per minute, while HVAC and compressed-air people talk in cubic feet per minute. The two meet in jobs such as a water pump described both ways on a supplier sheet, a tank that fills at a flow rate quoted in cubic feet, or a gas-to-liquid comparison in a process. Both units belong to the US customary system, and the conversion between them is a pure volume ratio. This page applies it. It also reverses, so a pump label in GPM can be expressed in CFM for a calculation done in cubic feet. Water treatment designers sometimes need that reverse step for chemical feed or for sizing air-lift systems, where air in CFM and water in GPM appear in the same equation.
Why the factor is 7.48052
The US liquid gallon is defined as exactly 231 cubic inches, and a cubic foot is exactly 12³ = 1,728 cubic inches. Dividing gives 1,728 / 231 = 7.480519480519..., a repeating decimal, so the page uses gal/min = ft³/min × 7.48051948052. Both definitions appear in NIST Handbook 44 and SP 811. The reverse factor is 231 / 1,728 = 0.13368055..., so 1 GPM equals about 0.13368 CFM. Practically, a 7.5 gallon bucket is close to one cubic foot, which is a handy mental model. Because every term is a defined integer count of cubic inches, the ratio is exact, and the only approximation is the number of digits displayed.
Default and other entries
The default 10 CFM converts to 74.8052 GPM. A 1 CFM flow is 7.4805 GPM, 3 CFM is 22.4416 GPM, 20 CFM is 149.6104 GPM and 100 CFM is 748.0519 GPM. In the opposite direction, 5 GPM is 0.6684 CFM, 12 GPM is 1.6042 CFM, 50 GPM is 6.6840 CFM and 100 GPM is 13.3681 CFM. A quick check: GPM numbers are about seven and a half times CFM numbers. If you get a number smaller than the input when converting CFM to GPM, the menus are reversed.
Pumps and water systems
Water pumps and well systems are rated in GPM at a given head or pressure. A household well pump that delivers 12 GPM is moving 1.6042 ft³ of water each minute, a figure that helps when you compare it with a tank sized in cubic feet. A garden hose might flow at 5 GPM or so under ordinary pressure, or 0.668 CFM, but the actual flow depends on pressure, hose diameter and length. The page does not predict flow in any real system. It restates a known flow, whatever its source. If you fill a 500 gallon tank at 12 GPM, the job takes about 42 minutes, and the same volume is 66.8 cubic feet, so at 1.6042 CFM it takes the same 41.7 minutes, a check that the two units tell one story. In a mixed team, one person may read the pump curve in GPM and another the blower sheet in CFM, so a shared note with both numbers prevents each from silently converting on their own with different rounding.
Gas flow in gallons is unusual, and that matters
Writing a gas flow in gallons is rare, because a gallon names a quantity of liquid and the amount of gas in a gallon depends on pressure and temperature. The conversion still holds as a pure volume statement. A 10 CFM compressor moves a volume per minute equal to 74.8 gallons of space, although the compressed air occupies much less volume at working pressure. Use the converted figure only where the volume flow itself is what matters, such as the inlet volume of a blower. Do not use it to describe how much compressed air a tank holds. An air-lift pump, for example, moves water with injected air, and its design rules relate the air volume in CFM to the water flow in GPM through ratios published in pump engineering references. This page supplies only the unit translation for such a ratio. Ratios of this kind are sometimes quoted as cubic feet of air per gallon of water, which is the plain volume ratio of the two flows divided by 7.4805.
US gallons and imperial gallons
The menus also offer UK gallons per minute, and the two gallons differ. The imperial gallon is 4.54609 liters, the US gallon 3.785411784 liters. One US GPM is about 0.8327 imperial GPM, so 10 US GPM is 8.3267 imperial GPM. An older British pump label or an Australian document may use imperial gallons, and applying the US factor to it understates the flow by about 20 percent. If the origin of a GPM figure is unknown, ask which gallon it is before converting.
Fire protection and irrigation context
Fire sprinkler design, hydrants and irrigation zones are described in GPM, and the values can be large, in the hundreds or thousands. A 100 GPM sprinkler demand corresponds to 13.37 CFM of water, which is a modest volume rate. Agricultural pumps in thousands of GPM run to hundreds of CFM. The page can place such figures next to equipment described in cubic feet per minute, for example an air-driven pump or a blower that supplies a process. Requirements for flow in fire systems are set by codes and the authority having jurisdiction, and the page does not state any.
Reading GPM digits
GPM figures on pump labels are usually whole numbers or one decimal. Converting 3 CFM gives 22.44155844 GPM from the engine, and 22.4 is plenty. Keep unrounded values in calculation chains, such as a tank filling time, and round at the end. The repeating decimals in the factor mean that long results always carry tails, so do not treat the last digits as meaningful. Match the precision of the input.
Pump curves and fire flows excluded
This page restates a volume flow in another unit. It does not size a pump, predict pressure loss, compare efficiency, set a fire protection flow or correct a gas volume for pressure. Equipment and codes govern those, and the manufacturer curve shows delivered flow at your head and pressure. Use the number here as a consistent translation between two ways of writing the same volume per minute. For a single entry, three decimal places is a sensible display, so 0.668 CFM for 5 GPM is as precise as most pump labels justify.