Same cubic foot, different clock
This is the simplest flow conversion in the US customary system, because both units use the same volume and differ only in the time base. Cubic feet per minute, abbreviated CFM, is the rating you see on fans, range hoods, dust collectors and compressors. Cubic feet per second, abbreviated cfs, is the standard unit of stream gauging in the United States and appears in reservoir releases, culverts and storm drains. A reader who needs both is usually checking a pump or fan against a channel flow, or converting a fan schedule into the units a hydraulic formula expects. The page divides by 60 and presents the answer so you do not have to do it by hand.
The division by 60
There are 60 seconds in a minute, so a volume that passes at 60 ft³ each minute passes at 1 ft³ each second. The page uses ft³/s = ft³/min × 0.0166666666667, which is the same as dividing by 60. Because 60 divides evenly into many round numbers, many conversions come out as short decimals. 120 ft³/min is 2 ft³/s, 450 ft³/min is 7.5 ft³/s and 600 ft³/min is 10 ft³/s. The reverse multiplies by 60, giving 180 ft³/min for 3 ft³/s and 30 ft³/min for 0.5 ft³/s. A middle value, 1 ft³/s, is 60 ft³/min, which is an easy anchor to remember when you estimate by hand. The second is the SI base unit of time and the minute is accepted for use with the SI, as the BIPM SI Brochure explains, so no experimental constant is involved. The exact result is a rational number, so the repeating decimal 0.0166... is just a way of writing one sixtieth.
What the default tells you
With 10 ft³/min, the page returns 0.1667 ft³/s, written in full as 0.16666666666666666. That is one sixth of a cubic foot every second, about 4.7 liters per second. A flow that small is typical of a household fan rather than a stream. For a stream gauge reading of 10 cfs, the same calculation in reverse gives 600 ft³/min, which shows how quickly the numbers in cfm grow for natural flows. Remember that cfs and CFM differ only in the time base and not in volume, so both use the same cubic foot of 0.028316846592 m³. If you ever see a stream described in CFM, check the source, because hydrology reports almost always use cfs, and misreading the time base produces an error of exactly 60.
Where cfs is the working unit
US Geological Survey streamgage data are published in cubic feet per second, and many water-rights and flood-flow figures in the western United States use the same unit. Indian and Pakistani irrigation engineers use the cusec, which is one cubic foot per second. A small creek might carry a few cfs in summer, while a major river carries thousands. The page does not interpret the figure, but it lets you express a pump rated at 450 ft³/min as 7.5 ft³/s, so you can see how much of a stream, say 30 cfs, it would remove. Always check local rules for diversion limits, because the converter does not know them.
Where CFM is the working unit
In heating and ventilation, airflow is quoted in CFM. Residential bath fans, kitchen hoods and whole-house systems are rated by CFM, as are dust collection systems in woodworking shops. Compressors are rated in CFM or SCFM, where the S indicates a standard reference condition. Engineers who size ducts sometimes use per-second velocities in feet per second, so a CFM figure divided by 60 is the flow in ft³/s that, divided by duct area in square feet, gives the average velocity in feet per second. A 120 CFM fan equals 2 ft³/s, and in a duct of 0.5 ft² the average velocity is 4 ft/s.
Pitfalls with seconds and minutes
The most frequent error is applying the factor in the wrong direction. Dividing by 60 makes the number smaller, because the same volume spread over seconds gives a smaller figure per second. If you enter a flow in cfm and your result is larger than the input, the menus are set backward. Another error is mixing cfs with cubic meters per second. One ft³/s is 0.0283168 m³/s, a factor of about 35 apart. A third is confusing cfm with SCFM and ACFM, which are not interchangeable because gas volume depends on pressure and temperature, and the page treats the input as given.
Relating to gallons and acre-feet
Hydraulic work often converts cfs to other units. One cfs is about 448.83 US gallons per minute, since 60 × 7.48052 gallons gives 448.83. A steady 1 cfs over a day delivers 86,400 ft³, about 1.9835 acre-feet, because one acre-foot is 43,560 ft³. Those relations let you check a converted number against another common unit. Starting from 450 ft³/min, the page gives 7.5 ft³/s, and 7.5 × 448.83 gives about 3,366 US gallons per minute, which is the same flow in a form pump curves often use. Those two steps agree with what the From and To menus produce when you pick US gallons per minute as the target.
Rounding fan airflow in cubic feet per second
The output carries double precision digits, but input flows are rarely known beyond two or three significant figures. A fan labeled 450 CFM may deliver more or less in a real duct run, because the label usually refers to test conditions with little or no static pressure. Report 7.5 ft³/s, not 7.500000 ft³/s. When two fans run together, their flows add in either unit, so 450 CFM plus 150 CFM is 600 CFM, or 10 ft³/s, if the system pressure does not change the delivery of either fan. Gauge heights at streams are converted to flow by rating curves with uncertainty of several percent, so the extra digits would suggest accuracy that does not exist.
What this conversion does not do
The page restates the same volume flow in another time unit. It does not size ducts, pumps or culverts, estimate velocity, correct gas flow for pressure and temperature, or determine whether a diversion is allowed. Those depend on geometry, fluid properties and local regulations. Use the converted number as one step in a larger calculation and take limits from equipment documentation and the relevant authority. For a duct or channel, continuity ties the converted flow to the cross-section area and the average velocity, a relation the page leaves for you to apply.