Getting a chip-scale energy into SI base units
Energy figures for individual electronic events are quoted in femtojoules because that avoids a string of negative exponents, but formulas for power, temperature rise, efficiency and battery life are written in joules. Converting a per-operation energy to joules is the usual first step before multiplying by an operation rate to get watts, or by a count to get a total. A processor datasheet that gives 20 fJ per bit has to be turned into 2e-14 J before it can be combined with a rate in hertz to produce a power in watts. This page performs that step and returns a value ready to use in a script or a spreadsheet that works in SI base units.
The joule and the prefix
The joule is the SI derived unit of energy. One joule is the work done by a force of one newton acting over one meter, which equals one watt second and one kg m² s⁻². The prefix femto stands for 1e-15 and is defined exactly in the SI Brochure and NIST SP 811. So J = fJ × 1e-15 with no uncertainty. The page prints the factor as 1e-15. In decimal, 1 fJ is 0.000000000000001 J. Because the factor is exact, this conversion is a clean example of a prefix change: nothing about temperature, material or measurement method enters, and the result depends only on the input value.
Floating point noise in the 10 fJ result
Entering 10 fJ returns 1.0000000000000002e-14 J. The intended value is 1e-14 J, and the trailing 2 appears because binary floating point cannot store 1e-15 exactly. A reasonable way to display the answer is 1.0e-14 J, or simply 10 fJ again if no further calculation needs SI base units. To picture the size, a 100 W lamp uses 100 J every second, so 10 fJ is a fraction of 1e-16 of one second of that lamp. The default demonstrates how small a single event energy is and why exponent notation is needed in the output.
Switching energy of a logic gate
Dynamic switching energy in CMOS follows E = C × V², often with a factor of one half depending on how it is defined. For a node with 5 fF of capacitance at 1 V, C × V² is 5e-15 J, which is 5 fJ. A circuit with 2,000,000 such nodes toggling once per cycle uses 1e-8 J per cycle, and at 1 GHz that is 10 W. Entering 5 fJ on this page gives 5e-15 J, the value that goes into the formula. The numbers are illustrative and a real chip has different capacitance, voltage and activity factors, but the chain from fJ to J to W is how such estimates are built.
Converting joules to femtojoules
The reverse multiplies by 1e15. A value of 3e-12 J is 3,000 fJ, a value of 2.2e-13 J is 220 fJ, and 1 J is 1,000,000,000,000,000 fJ. This direction is useful when a simulator reports total energy in joules and you want per-event energy in a friendlier unit. Divide the total by the number of events first, then convert. For example, 3e-9 J spread over 1,000 events is 3e-12 J per event, which is 3,000 fJ or 3 pJ. Doing the division in joules and converting last reduces the risk of a prefix error in a long calculation. A second example: a memory array that spends 1.5e-6 J reading 1,000,000 bits spends 1.5e-12 J, or 1,500 fJ, per bit.
Joules, watts and time
Energy and power are different quantities, linked by time. One watt is one joule per second, so a device that uses 10 fJ per event and runs 1e9 events per second draws 1e-5 W, which is 10 µW. A common mistake is to write a power in a unit of energy, for example calling 10 µW a 10 µJ figure. This converter handles energy only, so it cannot tell whether a number is a rate. Check that your input is energy per event or total energy, and bring the time dimension in separately when you need power. Multiplying energy by frequency gives power, and dividing power by frequency gives energy per cycle.
Other ways to write the same energy
One joule equals one newton meter, one watt second, 1e7 erg, 6.241509e18 eV, 0.2390057 thermochemical calories and 2.777778e-7 kWh. These exact or near-exact relations are tabulated in NIST SP 811. A femtojoule is therefore 1e-8 erg, which makes the CGS unit surprisingly convenient at this scale: 10 fJ is 1e-7 erg. The newton meter is the same unit as the joule, though by convention it is reserved for torque, and writing J for torque is discouraged because it invites confusion between the two quantities. Femtojoules are used for energy and never for torque. In older CGS literature the erg is the working unit, and a result in erg converts to femtojoules by multiplying by 1e8.
Simulation output digits and joule precision
The factor 1e-15 is exact, so the number of meaningful digits in the answer equals the number in your input. Simulation outputs often give six or more digits, while measured energies rarely have more than three. Round the converted value to match, so a simulated 12.4 fJ becomes 1.24e-14 J and not 1.240000000000000e-14 J, and prefer exponent notation, such as 1.0e-14 J, over a long decimal string. If a result is to be pasted into another tool, check that it parses the exponent form correctly. Some older software does not accept a lowercase e, and some locales use a comma as decimal separator, which can turn 1.5e-14 into a different number or an error. When values pass between a simulator, a spreadsheet and a document, check one known number, such as 1 fJ equals 1e-15 J, after each hand-off.
What the converter covers
The converter rescales an energy value from femtojoules to joules and says nothing beyond that. It does not compute switching energy, estimate power or evaluate heat dissipation. Those need capacitance, voltage, frequency and thermal data that are not part of this page. The unit relation comes from the SI Brochure and NIST SP 811. Use the result as a unit-consistent input for a formula you have chosen, and take device parameters from datasheets, models or measurements. Keep in mind that energy per operation quoted by a vendor can include or exclude memory access and wiring, so two femtojoule figures are comparable only when they describe the same boundary.