Charge amplifiers and detector pulses

Femtocoulombs turn up where a sensor produces a tiny packet of charge: photomultiplier pulses, particle detectors, piezoelectric sensors and charge-sensitive preamplifiers. A datasheet or a paper may give the output charge in fC, while an equation, such as Q = C × V or I = Q / t, needs coulombs. This page converts one to the other. Going to coulombs matters most when a result is going into a formula that assumes SI units, since the number will carry the exponent −15 and a missing exponent gives an answer wrong by a factor of a quadrillion. Researchers in nuclear electronics, mass spectrometry and optics all meet the unit, and a mismatch between a paper and a model is a common source of confusion.

The exact prefix factor

Femto stands for 10^−15, so 1 fC is 0.000000000000001 C. The SI Brochure defines the prefix, which makes the factor exact. Entering 10 fC gives 1 × 10^−14 C, and the page may display 1.0000000000000002e-14 because of binary arithmetic. Read it as 1 × 10^−14. The reverse direction multiplies by 10^15, so 1 C is 1,000,000,000,000,000 fC. The coulomb itself is defined since 2019 by fixing the elementary charge at 1.602176634 × 10^−19 C, so charge in coulombs is tied directly to a count of electrons. The two-step route is fC to pC, a factor of 0.001, then pC to C, a factor of 10^−12, with the same total.

What 10 fC means

The default of 10 fC is about 62,415 elementary charges, a little more than sixty thousand electrons. That is a size that scientific image sensors handle routinely, because a pixel can hold tens of thousands of electrons before it saturates. Full-well capacities are listed in electrons, so 10,000 electrons correspond to 1.602 fC and 100,000 electrons to 16.02 fC. As a charge in coulombs it is 1 × 10^−14 C. A current of 1 pA flowing for 10 ms moves the same amount, since 10^−12 A × 10^−2 s = 10^−14 C. The link between current, time and charge is often what a user of this converter is trying to compute.

Photomultiplier gain

A photomultiplier tube turns one photoelectron into a large pulse of electrons, with a gain that is often around 10^6. One photoelectron times a gain of 10^6 yields 10^6 elementary charges, which is 1.602 × 10^−13 C, or 160.2 fC at the anode. Spread over a pulse of a few nanoseconds, that charge forms a current pulse of tens of microamperes at the peak. The conversion lets you move between the charge per pulse quoted by a vendor in fC or pC and the coulombs a model requires. The gain figures here are illustrative, and each tube has its own. Gain varies with the high voltage applied, which is why vendors specify it at a stated supply voltage.

Charge injection in switches

Analog switches and sample-and-hold circuits inject a small charge into the signal path when they turn on or off. Datasheets list this charge injection in picocoulombs, typically a few to several tens, so values in femtocoulombs appear in better parts or in the effect on small capacitors. Charge Q on a capacitor C changes the voltage by Q/C, so 2,500 fC, or 2.5 × 10^−12 C, on a 1 nF hold capacitor shifts the voltage by 2.5 mV. The converter gets the charge into coulombs for that formula, and the formula then yields volts directly. A larger hold capacitor reduces the error from the same injected charge, at the cost of a slower settling time.

Using Q = C × V

A 3.3 fF capacitor charged to 1 V stores 3.3 fC, which is 3.3 × 10^−15 C. In a memory cell with 25 fF and a 1.2 V swing, the stored charge is 30 fC, or 3 × 10^−14 C. These examples are illustrative and show how the unit sizes match: a femtofarad times a volt is a femtocoulomb. That neat pairing is why designers who work in fF and V can read charge directly in fC. The page is what you need when the final step requires coulombs, such as comparing with a measured current integrated over time. Reversing the formula, 30 fC at 1.2 V implies a capacitance of 25 fF, and a swing of 0.6 V halves the charge to 15 fC.

Going from coulombs to femtocoulombs

Select coulombs as the From unit and femtocoulombs as the To unit. A value of 2.5 × 10^−12 C, typed as 0.0000000000025, returns 2,500 fC. A charge of 1 × 10^−13 C returns 100 fC. Because typing many zeros is error prone, it helps to check the answer against an estimate. If a charge of a few picocoulombs returns a result in the millions or in the thousandths, a decimal place was misplaced. Many tools accept exponent entry such as 2.5e-12, which is safer. Every three steps of the exponent move one prefix, so 10^−12 C is a picocoulomb and 10^−15 C is a femtocoulomb.

Noise and resolution

Charge measurements at this level are limited by noise. Thermal noise on a capacitor, often called kTC noise, has an RMS charge of √(kTC). At room temperature on a 1 pF capacitor that is roughly 0.064 fC, about 400 electrons, and it grows with the square root of the capacitance. Specialized electronics reach resolutions of a few electrons, which is under a thousandth of a femtocoulomb. Report converted values with the digits justified by the measurement, and treat extra digits from the arithmetic as noise.

Currents, capacitance and calibration are separate questions

The page changes the unit of a charge. It does not compute currents, capacitances or voltages, judge whether a measurement is valid, or estimate calibration errors. It does not calculate installation limits, equipment ratings, protection, material response or compliance. Use the datasheet and the measurement method for those questions. A detector vendor may also quote pulse charge as an RMS noise figure in electrons, and multiplying that count by 1.602 × 10^−4 fC converts it to femtocoulombs before the coulomb step. Charge is also different from current, which is charge per second: a pulse of 160 fC lasting 3 ns carries a mean current near 53 µA.