Putting a pulse next to a battery rating

Battery capacity is quoted in milliampere-hours, while a device's activity is often measured in charge per event or as current multiplied by a short time. To see how much of a battery one event uses, both need the same unit. The relationship is fixed by definition: 1 mAh is 0.001 A for 3,600 s, which equals 3.6 C, or 3,600 mC. This page divides millicoulombs by 3,600 to give milliampere-hours. It answers questions such as how much of a coin cell a single radio transmission uses, which would otherwise require a conversion in your head. Product designers use the same comparison when they set a transmit duty cycle, because the battery label sets the budget and the firmware decides how fast it is spent.

The factor 3,600 and where it comes from

An hour has 3,600 seconds, and an ampere is one coulomb per second. A current of one ampere sustained for one hour therefore moves 3,600 C, so 1 Ah is 3,600 C. Dividing by 1,000 gives 1 mAh as 3.6 C, and since 1 C is 1,000 mC, 1 mAh is 3,600 mC. The formula on the page is mAh = mC × 0.000277777..., which is the same as dividing by 3,600. The factor is exact because the hour is defined as 3,600 seconds for this purpose and the coulomb as one ampere-second. The hour is a non-SI unit accepted for use with the SI, and the ampere-hour is a common practical unit for battery charge in the same way. Dividing by 3,600 is therefore a definition-level step and carries no measurement uncertainty of its own.

Reading the default of 10 mC

The default input of 10 mC gives about 0.0027778 mAh. That is a small fraction of a typical battery, which makes sense, since 10 mC is only 0.01 C. For a quick check, 3,600 mC should return exactly 1 mAh and 7,200 mC should return 2. If you enter a millicoulomb value smaller than 3,600, the answer is below one milliampere-hour. The page shows many decimal places for small inputs because the result is a repeating decimal, so round it to the precision that matters for your battery comparison. Three significant figures are plenty when the battery rating itself is only stated to two or three, and writing 0.00278 mAh for the default is clearer than copying fifteen digits into a report.

A sensor node waking up

Suppose a wireless sensor draws 50 mA for 20 ms every time it wakes to transmit. The charge per wake-up is 0.05 A × 0.02 s = 1 mC. Entering 1 mC returns about 0.000278 mAh. With 24 wake-ups a day, the radio uses roughly 24 mC, or 0.00667 mAh, per day, and a year of daily use adds up to about 2.4 mAh. A 220 mAh coin cell holds 792,000 mC, so this activity alone would use around one percent of the cell in a year. Real battery life also depends on sleep current, temperature and the cell's chemistry, which this converter does not model.

Going from battery capacity to millicoulombs

The converter also runs in reverse. A 220 mAh coin cell stores 220 × 3,600 = 792,000 mC, equal to 792 C. A 2,000 mAh pack holds 7,200,000 mC. Expressing a battery in millicoulombs helps when the loads you are comparing are given as pulses in the same unit. You can then divide the battery charge by the pulse charge to get the number of pulses, as a first estimate. Swap the menus and enter the battery rating in milliampere-hours to see the equivalent in millicoulombs. For the 220 mAh cell and a pulse of 1 mC, the estimate is 792,000 pulses, before allowing for self-discharge, the cutoff voltage and the sleep current between pulses, all of which reduce the real number.

Fitness trackers and small gadgets

Wearables and tags with batteries between 20 mAh and 300 mAh deal with charge in small increments. A 100 mAh battery equals 360,000 mC. A display refresh that costs 15 mC consumes 0.00417 mAh, so roughly 24,000 refreshes would use the full battery if nothing else drew current. That bound is theoretical, because the battery cannot be fully discharged in practice and other circuits draw power continuously. Still, converting the refresh cost to milliampere-hours puts it on the same scale as the manufacturer's capacity figure and makes the comparison concrete. A tag that refreshes twice a day and draws that 15 mC each time uses about 0.0083 mAh daily, which is why designers of such devices spend their effort on the always-on current rather than on the refresh itself.

Reading a USB power meter

Inexpensive USB meters count the charge that passes through them and display it in mAh. If a meter shows 1,800 mAh after charging a small speaker, the page converts that to 6,480,000 mC, or 6,480 C. Comparing it with the speaker's labeled battery capacity gives a rough idea of how much of the charge went into the cell. A figure noticeably above the rating is normal, since charging is not perfectly efficient and some current is lost as heat in the charging circuit. If you want a counter reading in coulombs for a physics write-up, this is the direct route from the meter's display unit to the SI unit.

Capacity ratings are conditional

A milliampere-hour rating depends on the discharge rate, the cutoff voltage and the temperature at which it was measured. A cell rated at 100 mAh at a gentle current may deliver less when drained quickly. The coulomb value from this page is the charge you want to move, and the battery rating is the charge the cell can supply under stated conditions. They are the same kind of quantity, but a datasheet capacity is not a guarantee for every load. The page makes no allowance for efficiency, voltage regulators or aging, so apply your own margin when you plan around a rating.

Milliampere-hours do not give energy

Charge in milliampere-hours or millicoulombs is not energy. To compare batteries of different voltages, multiply the capacity in ampere-hours by the nominal voltage to get watt-hours. A 1,000 mAh cell at 3.7 V holds 3.7 Wh, and a 1,000 mAh cell at 1.5 V holds only 1.5 Wh. This page converts the charge only. It does not calculate energy, runtime, installation limits, protection or compliance, so combine the result with the rest of your design data and the manufacturer's ratings.