Small battery labels meet large battery ratings

Phones, earbuds and power banks are labeled in mAh, while lead-acid car batteries, deep-cycle batteries for campers, solar charge controllers and e-bike packs use Ah. Anyone sizing a backup battery for a router, or comparing a 20,000 mAh power bank with a 12 V battery meant to run a small fridge, ends up with numbers in two scales. This page moves the decimal three places so both belong to the same scale. It converts the stated capacity only. It does not say how long a device will run, since that depends on current draw, voltage and the state of the cell, and it does not check whether a battery suits a charger or an appliance.

One thousand mAh in one Ah

An ampere is one coulomb per second, and an ampere hour is the charge carried by one ampere flowing for 3,600 seconds, which is 3,600 coulombs. A milliampere hour is one thousandth of that, or 3.6 coulombs. The relationship is therefore Ah = mAh × 0.001, and the default input of 10 mAh returns 0.01 Ah. Going back, multiply Ah by 1,000. The factor is exact because the prefix milli- means 10⁻³ in the SI Brochure published by the BIPM, and the hour is defined as 3,600 seconds. There is no rounding in the conversion itself, only in the displayed digits of long results.

From a phone label to an Ah figure

A phone rated 5,000 mAh holds 5 Ah of charge. A pair of AA cells at 2,600 mAh each is 2.6 Ah per cell, and a 750 mAh camera battery converts to 0.75 Ah. A 20,000 mAh power bank is 20 Ah. These values describe charge, so they do not compare directly across different voltages. A 20 Ah figure on a 3.7 V lithium cell stores far less energy than 20 Ah on a 12 V pack. The charge figure answers how long a given current can flow, and the voltage must be added later to turn it into watt-hours.

A first runtime estimate

Once the capacity is in Ah, a rough runtime follows by dividing it by the load current in amperes. A 2.6 Ah cell feeding a 0.5 A load would in theory last 5.2 hours. The same arithmetic with the unconverted 2,600 mAh needs the current in milliamperes, 500 mA, to give the same 5.2 hours. Mixing 2,600 mAh with 0.5 A produces an answer that is off by a factor of 1,000, which is the most common slip this converter prevents. Real packs deliver less than the label at high currents or in the cold, so treat the result as an upper bound for planning.

Adding voltage to reach watt-hours

Energy in watt-hours is charge in ampere hours multiplied by voltage. A 5,000 mAh phone cell at a nominal 3.7 V stores 5 × 3.7 = 18.5 Wh. Smaller electronics are often compared on that basis, because watt-hours decide how much work the battery can do regardless of its voltage. The nominal voltage comes from the datasheet and changes as the cell discharges, so the result is a label-level figure. If you only have the Ah value of a 12 V pack, multiply by 12 for watt-hours, remembering that useful capacity is lower than full capacity for lead-acid types that should not be drained completely.

Bulk capacity on a car or solar bench

A 60 Ah car battery equals 60,000 mAh, and a 100 Ah solar storage battery equals 100,000 mAh. Typing those into the reverse direction is a quick way to see why mAh is a poor unit at that scale, with six digits and a decimal point easy to misplace. Installers usually work in Ah for the same reason. If you are replacing a battery with another brand, compare capacity in the same unit and check the rated discharge rate, since an Ah figure is tied to a stated discharge time. That rating condition is printed on the datasheet and not in the conversion.

Coin cells and tiny loads

Coin cells carry capacities in the low hundreds of mAh, so a figure of 225 mAh, used here as an illustration, is 0.225 Ah. A sensor that draws only microamperes can in principle run for years from such a cell, but the label capacity applies to a specific load and temperature. When the datasheet lists a capacity at a given discharge current, convert only the number and keep the condition next to it. The converter does not derate for self-discharge or for high pulse currents, both of which matter in small devices that wake briefly to transmit.

Charging time from capacity in Ah

The same conversion helps when you plan a charge. A 5,000 mAh phone battery is 5 Ah, and a 2 A charger would need about 2.5 hours to supply that much charge if everything were perfectly efficient. Real charging takes longer, because the current tapers near the end of the cycle and some energy is lost as heat. For a larger pack the numbers scale the same way: a 10 Ah e-bike pack on a 2 A charger needs at least 5 hours. Using Ah on both sides, the battery and the charger current, keeps the division clean and avoids the factor of 1,000 that appears when one side is in milliamperes. Most chargers print their output in amperes or in milliamperes depending on the size of the device, so check the unit on the adapter label before dividing.

Aged cells and charger compatibility

The page restates the same charge in Ah and nothing more. The charge current limit and the charger type are printed on the cell or in its data sheet, and the page cannot tell whether a battery is safe to charge or fit for a given charger. A capacity printed on a label is a manufacturer claim measured under stated conditions, and aged cells hold less. Use the converted value as the starting point for your own sizing, and follow the manufacturer guidance for charging and discharging limits. Capacity also falls as a cell ages through repeated charge cycles, so a battery bought three years ago may no longer deliver the figure on its case. Where the number decides something that matters, such as backup power for equipment you depend on, measure the capacity with a load test or ask the maker for an aged-cell rating, and keep a margin of at least a few tens of percent over the calculated need.