Why nanofarads dominate European schematics

Many European schematics and bills of materials write small capacitors in nanofarads, such as 100 nF, 220 nF or 4n7, while American drawings tend to use microfarads or picofarads for the same parts. A 100 nF part is 0.1 µF. When a design that uses a large reservoir capacitor in millifarads is matched to a parts list in nanofarads, a conversion is needed. The formula is nF = mF × 1,000,000, so the default 10 mF is 10,000,000 nF. The page makes it easy to see how many nanofarads a big capacitor represents and how small the other parts on the board are by comparison. Hobbyists who order parts from European suppliers meet the notation most often, because online catalogs there list film and ceramic capacitors in nF as a matter of course, and the converter bridges that gap when a design from a US magazine is rebuilt from a European parts list.

The default of 10 mF in nanofarads

The default entry of 10 mF returns 10,000,000 nF, which is 1 × 10⁷ nF. A million-fold change is large enough that a digit slip creates a wrong result with little warning. The simple check is to go via microfarads: 10 mF is 10,000 µF, and 10,000 µF times 1,000 is 10,000,000 nF. The same check works for any value. For 4.7 mF, the page returns 4,700,000 nF, which is 4,700 µF. If your answer has the wrong number of zeros, redo the conversion in two steps, and enter very large results with an exponent, such as 1e7, when you copy them into other tools. Smaller inputs behave the same way: 0.5 mF is 500,000 nF and 0.022 mF is 22,000 nF. A capacitor labeled 22 µF in a power-supply filter is 22,000 nF, which gives a feel for how long the numbers get when a parts list is forced into nanofarads only.

Decoupling capacitors next to a large reservoir

A typical digital board has a bulk capacitor near the power input and many 100 nF ceramic capacitors close to each integrated circuit. A bulk part of 4.7 mF is 4,700,000 nF, which is 47,000 times the value of a 100 nF bypass part. That ratio explains the division of labor: the bulk capacitor supplies slow changes in demand, and the small ones supply fast edges because they sit closer to the chip and have lower inductance. The page makes the ratio visible. It does not choose values for you, which depend on the load, the supply and the layout. Datasheets for microcontrollers and voltage regulators usually state a recommended value for each supply pin, commonly 100 nF, and follow it with a note on placement, and the guidance in those documents takes precedence over any rule of thumb. For a board with eight supply pins, eight 100 nF parts total 800 nF, which is 0.0008 mF, a small fraction of one bulk capacitor.

Reading the shorthand notation

Schematics often write nanofarad values with the letter n in the place of the decimal point, for example 4n7 for 4.7 nF and 100n for 100 nF. Converting 4n7 to millifarads gives 0.0000047 mF. In the other direction, entering 0.0047 mF returns 4,700 nF, which is written 4µ7 or 4.7 µF on the part. The shorthand avoids a decimal point that could be lost in printing, but it has to be read carefully. Typing the value in full on this page and checking the result against the part's marking confirms the reading.

Using the page for parts lists

When a spreadsheet lists capacitors in different units, a column in nanofarads makes sorting and totals meaningful. For example, 0.0047 mF, 220 nF and 0.1 µF can all be placed in nanofarads as 4,700, 220 and 100. A formula of =A2*1000000 does the job for a column in millifarads. Test one row against the page before applying the formula to the whole column. Parts that arrive in microfarads need a different multiplier, 1,000, and mixing the two multipliers in one column is a common cause of a total that is off by a factor of a thousand. Giving each source column its own labeled conversion column prevents that. After the conversion, sorting by value gives a sensible order that a mixed-unit column would not.

Filter and timing circuits

The cutoff frequency of a simple RC low-pass filter is f = 1 / (2π × R × C). With R = 1 kΩ and C = 100 nF, the cutoff is about 1,592 Hz. The formula needs C in farads, so 100 nF is 1 × 10⁻⁷ F, which is 0.0001 mF. Converting between these units in your head is where mistakes occur, since each of the three forms looks plausible. The example is illustrative; component tolerances and the source and load impedance shift the real cutoff, and the page performs only the unit conversion. Doubling the capacitor to 200 nF halves the cutoff to about 796 Hz, and the corresponding input to this page would be 0.0002 mF. Keeping the capacitance in one unit while you vary it makes such comparisons less error-prone.

Going back to millifarads

Swap the menus to divide by one million. A value of 470 nF equals 0.00047 mF and 4,700 nF equals 0.0047 mF. Values this small are awkward in millifarads, which is a sign that the unit is poorly matched to the part. A reader who sees 470 nF understands the size of the capacitor at once, while 0.00047 mF takes more effort. Use the conversion to check calculations, and then report the value in the unit that matches the part and the convention of the document. Writing 470 nF, 0.47 µF or 4n7-style shorthand according to the audience is a matter of style, as long as the unit symbol is present and the value is the same in every form.

Tolerance and measurement

Ceramic capacitors in the nanofarad range have tolerances from 1 percent for precision types to 20 percent or more for general-purpose types, and the capacitance of some dielectrics drops under DC bias. A nominal 100 nF part may measure noticeably less in circuit. The converted value on this page is the nominal figure, and it says nothing about the actual part. If the design depends on the value, consult the data sheet for tolerance, temperature coefficient and bias behavior, and measure the part when needed.

What the page does not cover

The page converts a unit of capacitance. It does not choose parts, simulate circuits or check voltage ratings, ESR, ripple current or temperature limits, and it does not evaluate installation limits, equipment ratings, protection or compliance. Large capacitors can hold charge after power is removed, so follow the manufacturer's instructions and applicable safety rules when handling them.