Why gas and heat buyers move from BTU to gigajoules

In the United States natural gas is sold by the MMBtu, a million BTU. In Canada the gas market quotes prices per gigajoule, and statistical offices in many countries report energy in joules and its multiples. A buyer, trader or student who reads a US price or heating value and needs a metric equivalent converts BTU to gigajoules. The default input of 10 BTU gives 0.0000105505585262 GJ, far too small to matter in practice, so real work uses thousands or millions of BTU. The page is most often used with an input of 1,000,000, which is one MMBtu and returns 1.05505585262 GJ.

The factor and the definitions behind it

The International-table BTU is 1,055.05585262 J according to NIST SP 811. The prefix giga means 10^9 in the SI Brochure, so a gigajoule is 10^9 J. Dividing gives 1.05505585262e-6 GJ per BTU, and the reverse factor is 947,817.12 BTU per GJ. These are exact consequences of the definitions. The energy content of a particular fuel is a separate matter, because heating values change with composition and with whether the water in the combustion products is counted as vapor or liquid. The converter only changes the unit of an energy you already know. It cannot tell you how many BTU a given volume of gas contains.

MMBtu to gigajoules for a gas bill

Take a small supply contract for 2,500 MMBtu, which is 2.5e9 BTU. The page returns about 2,637.64 GJ for that input. A price of 3.00 dollars per MMBtu becomes 3.00 divided by 1.05505585262, or about 2.8434 dollars per GJ, because each gigajoule is slightly less than an MMBtu in the other direction and slightly more in this one. Be careful with the direction. A gigajoule holds 0.9478 MMBtu, so a price per GJ is a little lower than the same energy priced per MMBtu. Quoting prices in the wrong unit would shift a contract by about 5.5 percent, which is large compared with ordinary price moves. The same care applies to volumes. A buyer who reads 2,500 GJ as 2,500 MMBtu would believe the contract holds about 5.5 percent more energy than it does, so the unit belongs in every cell that carries a quantity or a price.

Household scale and the megawatt-hour

A home furnace rated at 80,000 BTU/h running for ten hours uses 800,000 BTU of fuel energy, which is 0.844 GJ. One megawatt-hour of electricity is 3.6 GJ exactly, and the page shows that 3,412,141.6 BTU make up 3.6 GJ. A heat pump or an electric heater that draws 1 MWh therefore handles the energy of about 3.41 MMBtu in a gas bill. These comparisons help when a household or building owner has gas billed in one unit and electricity in another. The conversion treats the energy as energy only, and it ignores differences in how efficiently each source is turned into useful heat.

Reverse conversions from GJ to BTU

Selecting gigajoules as the source unit gives the BTU count. A fuel purchase of 5 GJ equals 4,739,085.6 BTU, or 4.74 MMBtu. One GJ is 947,817 BTU, so each GJ contains slightly less than a million BTU. This is useful when a metric supplier quotes a heating load and you must size equipment sold with US ratings. Divide the result by the hours of operation to find the BTU per hour comparison with a boiler nameplate, or divide by 3,412 to find kilowatt-hours roughly. The page itself converts only between the energy units, so any time or efficiency step has to be added by you.

Therms, decatherms and other gas units

US bills sometimes use the therm, defined commercially as 100,000 BTU. On the International-table basis a therm is 0.105505585 GJ, and a decatherm of 10 therms equals one MMBtu. Some utilities also bill by the hundred cubic feet or by the thousand cubic feet, with a heating-value factor on the bill that converts volume to energy. If your bill lists a factor, the energy in BTU is volume times that factor, and only then is the page applicable. Whether the factor is a higher or lower heating value should be stated on the bill, and the choice shifts the energy by roughly ten percent for natural gas.

Energy per year at a facility

A facility may state its annual consumption in GJ, as many government reporting schemes do. A building using 12,000 MMBtu per year of gas uses about 12,660.7 GJ. Compare that with a benchmark in GJ per square meter and you have an intensity figure in metric units. The page handles the unit change for the annual total, and you divide by floor area separately. Keep the year and the unit visible next to the value in your report, because a GJ per year is a different quantity from a GJ per month. Do not combine energy totals from different sources without confirming the same BTU definition.

Significant digits and a quick check

The factor is exact, so the digits in your answer should follow the digits of your input. A bill read to three digits justifies three digits in GJ. For a mental check, treat one BTU as about 1.055 kJ. One million BTU is about 1.055 million kJ, which is 1.055 GJ, in agreement with the page. If the result is off by a factor of 1,000, you have probably mixed megajoules and gigajoules, which are neighboring prefixes. The SI symbol is GJ, written without a space inside the symbol, and the amount is separated from it by a space.

Gigajoules and kilowatt-hours side by side

Electricity bills use kilowatt-hours, and one gigajoule is 277.78 kWh, from 1e9 J divided by 3.6e6 J per kWh. A heating comparison between a gas furnace and an electric resistance heater therefore starts by putting both on one scale. A household that burns 50 GJ of gas in a winter used about 47.4 million BTU, and the same 50 GJ of heat from an electric resistance heater would be 13,889 kWh. Gas furnaces lose part of the fuel energy in flue gas, so their delivered heat is less than the purchased energy, and heat pumps deliver more heat than the electricity they use. The page converts the purchased energy only, and the efficiency question remains separate. Put the efficiency figure from the equipment label into the comparison before drawing any cost conclusion.