MEASUREMENT & METHODS

Conventional inches of mercury (inHg (0 °C)): pressure unit guide

The inHg selection uses the conventional mercury-column pressure definition.

Measurement basis

Its recorded factor is 3,386.388640341 Pa under the 0 °C convention.

Definition conventions

Atmospheres are standard atmospheres. Mercury-column factors use the conventional 0 °C definition, and a torr is 1/760 of a standard atmosphere.

Conversion method

Multiply the inHg amount by the full stored factor, then use the receiving pressure definition.

Reference equivalent of inHg (0 °C)

1 inHg (0 °C) = approximately 3386.38864034 Pa.

Recorded scale factors: 3386.388640341 for inHg (0 °C); 1 for Pa.

Worked example

Known input: 10 inHg (0 °C). Reference equivalent: 33863.8864034 Pa. The return conversion gives approximately 10 inHg (0 °C).

The reference example keeps the mercury convention and pressure basis explicit.

Common reference values

Input (inHg (0 °C))Reference equivalent (Pa)
13386.38864034
516931.9432017
1033863.8864034
2584659.7160085
50169319.432017
100338638.864034

Compare one inHg (0 °C) with other units

Target unitEquivalent of 1 inHg (0 °C)Definition guide
Pascals (Pa)3386.38864034Read definition
Kilopascals (kPa)3.38638864034Read definition
Bars (bar)0.0338638864034Read definition
Pounds per square inch (psi)0.49115414747Read definition
atmospheres (atm)0.033421057393Read definition
megapascals (MPa)0.00338638864034Read definition
millibar (mbar)33.8638864034Read definition
Conventional millimetres of mercury (mmHg (0 °C))25.4Read definition

Pressure measured by a column of mercury

An inch of mercury is the pressure at the base of a column of mercury one inch tall. The conventional version used on this site fixes the mercury density at 13,595.1 kg/m³, which corresponds to mercury at 0 °C, and standard gravity at 9.80665 m/s². With those conventions one millimeter of mercury is 133.322387415 Pa, and one inch, at 25.4 mm, is 3,386.388640341 Pa, or about 3.386389 kPa. The page title adds the label (0 °C) because other versions exist. NIST SP 811 lists an inch of mercury at 32 °F and another at 60 °F, which is about 3,376.85 Pa, and the difference of roughly 0.3 percent matters only for precise work. The unit is not part of the SI, and it is accepted in the SI Brochure only in limited fields.

Torricelli and the barometer

The measuring principle goes back to 1643, when Evangelista Torricelli filled a glass tube with mercury, inverted it in a dish and saw the column settle near 760 millimeters, with an empty space above it. He concluded that the weight of the air balanced the column. The method became the standard barometer for centuries, and mercury was chosen because its high density keeps the column to a manageable height: a water barometer would need a tube about 10 meters tall. English-speaking countries read the column in inches, and continental Europe in millimeters, which is how the two units ended up as parallel traditions. Today most weather instruments use electronic sensors, but the readout is often still shown in the old unit.

Standard atmosphere and everyday values

The standard atmosphere is 101,325 Pa, which equals 29.9213 inHg on the conventional scale. In everyday weather reports, sea-level pressure in the United States usually falls between about 29.0 and 30.8 inHg. A reading of 30.00 inHg is 101.59 kPa or 1,015.9 hPa, 29.92 is 101.32 kPa, and a low-pressure system at 28.50 inHg is 96.51 kPa. Extreme values show the range: the lowest sea-level pressure ever recorded in a tropical cyclone, 870 hPa in Typhoon Tip in 1979, is 25.69 inHg, and the highest, 1,084.8 hPa in Siberia in 2001, is about 32.03 inHg. Convert by multiplying inHg by 3.386389 to reach kilopascals, or dividing kilopascals by 3.386389 to return to inches. A change of 0.01 inHg, the smallest step on most altimeter settings, is 33.86 Pa, or 0.34 hPa.

Altimeter settings in aviation

Aviation in the United States and several other countries sets altimeters with a pressure value in inches of mercury. The standard setting is 29.92 inHg, equivalent to 1,013.25 hPa, and pilots flying at higher altitudes use it so that all aircraft share the same reference. Below the transition altitude, a local altimeter setting is broadcast, for example 30.12. Near sea level, pressure falls by about 1 inHg for every 1,000 feet of climb, so a reading error of 0.10 inHg shifts the indicated altitude by roughly 100 feet. That is why a pilot flying from a high-pressure area to a low one without updating the setting will fly lower than the instrument says. Most other countries use hectopascals for the same purpose, so conversions between 29.92 inHg and 1,013 hPa are part of international flying.

Vacuum gauges and engine diagnostics

Inches of mercury is also the traditional unit for vacuum. A gauge marked in inHg vacuum counts how far below the outside atmosphere the pressure has fallen, so a reading of 18 inHg means about 18 inches below the ambient pressure. A healthy gasoline engine at idle commonly shows manifold vacuum in the high teens to low twenties, and a low or fluctuating reading helps technicians find leaks, worn rings or timing problems. HVAC technicians use deep vacuum pumps and read the final level in microns of mercury instead. A vacuum value is not an absolute pressure. A gauge reading of 20 inHg vacuum at sea level corresponds to an absolute pressure near 9.92 inHg, or about 33.6 kPa, found by subtracting from 29.92.

Gauge, absolute and the reference point

Whenever an inHg number appears, ask whether it is absolute, relative to vacuum, or relative to the local atmosphere. Barometric pressure is absolute, because it measures the weight of the air above the sensor against a vacuum. A vacuum gauge is relative to the atmosphere. Station pressure is the raw reading at the instrument, while sea-level pressure is reduced mathematically to what the reading would be at sea level, which is the number in weather reports. The two can differ by several inHg at a mountain site, since pressure drops about 1 inHg per 1,000 feet. Mixing these quantities is a typical way to get an answer off by several units, long before any conversion factor comes into play.

The temperature and gravity qualifiers

A column of mercury changes length with temperature, and its weight depends on local gravity, so a physical barometer reading needs corrections before it equals a pressure. Mercury expands by roughly 0.018 percent per degree Celsius in volume, which is why an uncorrected mercury barometer in a 20 °C room reads roughly 0.3 percent high once the scale expansion is allowed for, about 0.09 inHg at 30 inHg. The conventional unit avoids all of this by fixing the density and gravity numerically, so the factor 3,386.388640341 Pa is a definition, not a measured quantity. If a source writes only inHg with no temperature, the 0 °C convention is the normal assumption for conversion. Work with a column at 60 °F, in some engineering tables, needs that other factor.

Writing the unit and choosing a modern one

The symbol appears as inHg, in Hg or in. Hg, and the capital H and lower-case g come from the chemical symbol for mercury. Document the form your source used. Pascals and their multiples are the SI choice for pressure, and the SI Brochure treats the millimeter of mercury as a non-SI unit kept for blood pressure. The unit is falling out of use in the laboratory, partly because mercury is a toxic material now restricted in many instruments. Weather services in the United States still publish inches of mercury, so conversions to kilopascals, hectopascals and atmospheres remain common. Canadian weather services, by contrast, publish kilopascals, and a forecast of 101.6 kPa corresponds to 30.00 inHg, so the same weather can be reported with two different numbers on either side of a border. A good habit is to write both numbers, as in 29.92 inHg (101.325 kPa), so a reader in either system can check the value.

Precision and checking

  • Retain source pressure precision.
  • Keep the 0 °C definition with the label.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →