A common bridge between US and SI practice
American barometric pressure and altimeter settings are in inches of mercury, while Canada, Australia and most of the world quote atmospheric pressure in kilopascals or hectopascals. Engineers who work across borders, students who use SI in class and a barometer in the lab, and technicians who read a vacuum gauge against an SI specification all need the same conversion. This page applies kPa = inHg × 3.38638864034. The default 10 inHg returns 33.86388640341001 kPa. A standard reading of 29.92 inHg returns 101.3207 kPa, matching the standard atmosphere of 101.325 kPa within 0.005 kPa. The lists also include pascals, bar, megapascals, psi, atmospheres, millibar, torr and millimeters of mercury, so other units are available from the same page. The unit name on the page includes the 0 °C reference.
The origin of 3.38638864034
The factor comes from two fixed numbers. The conventional density of mercury is 13,595.1 kg/m³, and standard gravity is 9.80665 m/s². A column of 1 mm then exerts 13,595.1 × 9.80665 × 0.001 = 133.322387415 Pa, the conventional millimeter of mercury. An inch is exactly 25.4 mm, so one inch of mercury is 25.4 × 133.322387415 = 3,386.38864034 Pa, which is 3.38638864034 kPa. Because all three inputs are definitions, the factor is exact to the digits shown. The mental shortcut is that one inch of mercury is a bit over 3.4 kPa, or about 34 hPa. Ten inches is 33.9 kPa, 20 inches is 67.7 kPa and 30 inches is 101.6 kPa. For quick estimates, multiplying by 3.4 gives an error of 0.4 percent.
Weather reports
A US weather report of 30.00 inHg translates to 101.59 kPa, and 29.50 inHg to 99.90 kPa. Environment Canada gives pressure in kilopascals, so a Canadian forecast of 101.6 kPa corresponds to about 30.0 inHg. In hectopascals, the same values are 1,015.9 and 999.0. Pressure trends are quoted too. A fall of 0.10 inHg in three hours is 0.34 kPa, and a rise of 0.5 kPa is 0.15 inHg. If you compare the two countries' reports for a border city, remember that station pressure and sea-level pressure differ, and that most public reports give the sea-level value. The conversion does not adjust for that. It also does not correct the mercury reading for temperature, so use a corrected value from the instrument where one is available.
Automotive and shop vacuum gauges
A vacuum gauge on an engine intake manifold reads in inches of mercury of vacuum in US shops. A healthy engine at idle at sea level commonly shows a steady reading of roughly 17 to 21 inHg, which is 57.6 to 71.1 kPa below atmospheric pressure. The readings fall with altitude, by about 1 inHg for every 1,000 feet, because the atmosphere itself is thinner. Absolute pressure in the manifold is the local atmospheric pressure minus the gauge reading. At sea level with 101.3 kPa ambient, an 18 inHg reading means 18 × 3.386 = 61.0 kPa of vacuum, and the absolute pressure is about 40.3 kPa. The converter helps you move the gauge reading to SI. It does not perform the subtraction, which you do after deciding what reference the target document expects.
A worked example for a vacuum pump specification
A pump data sheet states an ultimate vacuum of 25 inHg. That means 25 inHg below ambient, so the pressure drop is 25 × 3.38638864 = 84.66 kPa. With standard atmospheric pressure at 101.325 kPa, the absolute pressure is 101.325 − 84.66 = 16.67 kPa. A European specification asking for 20 kPa absolute is therefore met by the pump at sea level. In the reverse direction, convert 98 kPa to inches of mercury: 98 / 3.38638864 = 28.94 inHg, which is a slightly low barometric pressure at sea level. Since 98 kPa is 980 hPa, this value corresponds to a mild low-pressure system. These examples use illustrative numbers. A pump on a high-altitude site produces a lower vacuum figure relative to ambient, and the rating applies at stated conditions.
Gauge versus absolute again
Inches of mercury can be absolute or relative, and the page cannot tell which. A barometer reading of 29.92 inHg is absolute. A manifold gauge reading of 18 inHg is a vacuum, measured downward from ambient. The labels differ by industry: HVAC and automotive gauges say inHg vac, power-plant condenser data says inHga, and SI documents write kPa(a) or kPa(g). Write the reference beside the number before converting, and convert the whole line, so that 18 inHg vac becomes 61.0 kPa below ambient and not simply 61.0 kPa.
Mercury temperature and local gravity
The conventional inch of mercury is a fixed number of pascals, whatever the real mercury temperature or local gravity. A real mercury column reads slightly differently. At 20 °C mercury is less dense than at 0 °C by about 0.36 percent, so the column stands higher for the same pressure. Gravity varies with latitude and altitude by around 0.5 percent between the equator and the poles. Precise barometry corrects for both. A reading of 30.00 inHg at 20 °C corresponds to about 29.89 inHg at 0 °C, which is 101.2 kPa instead of 101.6 kPa. For general use that difference is small, but it exceeds the rounding of the conversion. The page treats the input as the corrected, conventional value.
How much precision to keep
The factor is exact, but the readings are not. A household aneroid barometer is typically accurate to about 0.05 to 0.1 inHg, which is 0.17 to 0.34 kPa. A report of 101.3207481 kPa for a 29.92 inHg reading suggests an accuracy that nobody has. Report one decimal place in kilopascals for household barometers, two for laboratory ones. If you convert a set of readings, use the same number of decimals for all. Keep full precision during intermediate steps. If the target is hectopascals, multiply the kPa value by 10, and the one-decimal rule becomes whole hectopascals, which matches how weather services publish.
Limits of the page
This page changes pressure units, and one decision stays with you: what the number is measured against. A barometer reading and a manifold vacuum reading can both be written in inHg and look alike, yet one is absolute and the other is relative to ambient. The page applies no altitude or temperature correction, so it cannot turn a station reading into a sea-level value or a warm-mercury reading into a 0 °C one. Use it to translate numbers between documents, and take procedures from the aviation authority, the lab protocol or the equipment data sheet.
Mental arithmetic and a short table
You can do the conversion in your head with enough accuracy for most checks. Take the reading, multiply by 3, then add about 13 percent of the result. For 30 inHg the product by 3 is 90, and adding 13 percent gives 101.7, close to the exact 101.59. A short table of exact results helps. A reading of 28 inHg is 94.82 kPa, 29 inHg is 98.21 kPa, 29.80 inHg is 100.91 kPa, 30 inHg is 101.59 kPa and 31 inHg is 104.98 kPa. Each additional inch adds 3.386 kPa. The span of typical sea-level weather, from 29 to 31 inHg, therefore covers about 6.8 kPa, or 68 hPa. These numbers show how little the pressure moves in ordinary weather, and why a 0.1 inHg change is already noticed.
Pressure change with height
The pressure falls with height at a rate that depends on air density, and near sea level it is about 1.1 to 1.2 kPa per 100 meters. In US terms, that is about 1 inHg per 1,000 feet, which is 3.386 kPa per 305 meters or 1.11 kPa per 100 meters. A station 300 meters above sea level that reports 98.0 kPa corresponds to roughly 101.6 kPa at sea level after correction, or about 30.0 inHg. The correction adds about 3.6 kPa for the first 300 meters. Weather services apply a more detailed formula that includes temperature. The page does not make that correction, but it helps you see the scale of the effect when you compare a station value with a map value.
Condenser vacuum in power plants
Steam power plants specify the vacuum in the condenser in inches of mercury absolute. A well-run condenser might operate at 1.5 inHg absolute, which is 1.5 × 3.386 = 5.08 kPa, equal to 0.0501 atm. Lower pressure lets the turbine extract more energy from the steam, and the pressure is tied to the cooling water temperature, because saturated steam at 5.08 kPa has a temperature of about 33 °C. A document from a US plant and one from a European plant may use inHga and kPa(a) for the same quantity. Those are absolute values, so there is no subtraction from ambient. Be careful with the older practice of stating condenser vacuum as inches of mercury below atmospheric. A vacuum of 28.4 inHg then corresponds to an absolute pressure of about 1.5 inHg when the barometer reads 29.9.