Measurement basis
Its stored factor is 10^-6 m²/s.
Definition conventions
Centistokes and mm²/s are numerically identical and remain familiar labels within the same quantity converter.
Conversion method
Multiply mm²/s by 10^-6 for the reference.
Reference equivalent of mm²/s
1 mm²/s = approximately 0.000001 m²/s.
Recorded scale factors: 0.000001 for mm²/s; 1 for m²/s.
Worked example
Known input: 10 mm²/s. Reference equivalent: 0.00001 m²/s. The return conversion gives approximately 10 mm²/s.
The example applies the squared length scale.
Common reference values
| Input (mm²/s) | Reference equivalent (m²/s) |
|---|---|
| 1 | 0.000001 |
| 5 | 0.000005 |
| 10 | 0.00001 |
| 25 | 0.000025 |
| 50 | 0.00005 |
| 100 | 0.0001 |
Compare one mm²/s with other units
| Target unit | Equivalent of 1 mm²/s | Definition guide |
|---|---|---|
| Square meters per second (m²/s) | 0.000001 | Read definition |
| Stokes (St) | 0.01 | Read definition |
| Square feet per second (ft²/s) | 0.0000107639104167 | Read definition |
The unit lubricant labels use
One square millimeter per second is 10⁻⁶ m²/s, which makes it a decimal submultiple of the SI coherent unit for kinematic viscosity. It equals 0.01 stokes, and it is numerically identical to the centistokes, because 1 St is 1 cm²/s, which is 100 mm²/s, and a centistokes is one hundredth of that. ASTM D445 and ISO 3104 report results in mm²/s, and product specifications for fuels, hydraulic oils and gear oils quote the same unit. Stating a value as 46 mm²/s or as 46 cSt therefore describes the same fluid at the same temperature. This site keeps the cSt label on its converters for readers who know it.
Matching site converters and factors
The factors are simple. Multiply mm²/s by 10⁻⁶ for m²/s, by 0.01 for stokes and by 0.0000107639104167 for ft²/s. A 46 mm²/s oil is 4.6e-5 m²/s, 0.46 St and 4.95e-4 ft²/s. The tools are Square millimeters per second to Square meters per second converter (kinematic viscosity), Square millimeters per second to Stokes converter (kinematic viscosity) and Square millimeters per second to Square feet per second converter (kinematic viscosity). In the other direction there are Square meters per second to Square millimeters per second converter (kinematic viscosity), Stokes to Square millimeters per second converter (kinematic viscosity) and Square feet per second to Square millimeters per second converter (kinematic viscosity). Because the units differ only by powers of ten and the foot, none of these conversions needs a density or a temperature, unlike a conversion to a dynamic unit.
How a capillary viscometer gives mm²/s
The standard laboratory method times how long a fixed volume of liquid takes to run through a calibrated glass capillary under gravity. The flow time in seconds multiplied by the instrument constant, in mm²/s², gives the kinematic viscosity directly. With an illustrative constant of 0.0300 mm²/s² and a flow time of 1,533 s, the result is 46.0 mm²/s. ASTM D445 requires the bath temperature to be held within 0.02 °C, because lubricating oils change viscosity by several percent per degree. Results are reported with three or four significant figures, together with the test temperature, which is part of the value.
ISO viscosity grades for industrial oils
ISO 3448 defines industrial liquid lubricant grades by their kinematic viscosity at 40 °C in mm²/s. The grade number is the midpoint, with a tolerance of plus or minus 10 percent. ISO VG 32 spans 28.8 to 35.2 mm²/s, ISO VG 46 spans 41.4 to 50.6, and ISO VG 68 spans 61.2 to 74.8. Hydraulic systems specify a grade because pump clearances and heat build-up depend on viscosity. A grade names a range, so two oils sold as VG 46 may differ by several mm²/s. The temperature belongs to the grade, so a VG 46 oil measured at 100 °C will read far lower.
Engine oil grades at 100 °C
SAE J300 classifies engine oils partly by kinematic viscosity at 100 °C. An SAE 30 oil must lie from 9.3 mm²/s up to but below 12.5 mm²/s, and an SAE 40 oil from 12.5 up to below 16.3. The W grades such as 0W or 10W are defined by cold-cranking and pumping viscosity at low temperatures, which use other units. A multigrade oil like 10W-40 must meet both the low-temperature limit of its W grade and the 100 °C range of its hot grade. The ratio between the 40 °C and 100 °C kinematic values gives the viscosity index, a measure of how much an oil thins as it warms.
Reference points from water to glycerol
Water at 20 °C is close to 1.0 mm²/s, a figure often used as the base of the scale. Air at the same temperature is about 15 mm²/s, which is 15 times higher, because its low density outweighs its very low dynamic viscosity. Gasoline is around 0.6 mm²/s, and EN 590 diesel must fall between 2.0 and 4.5 mm²/s at 40 °C. Glycerol at 20 °C is near 1,100 mm²/s. Honey and heavy fuel oils sit higher still. These magnitudes are typical values, since each fluid shifts with temperature and composition, so use the data sheet for a design number. The values decide the flow regime: water at 20 °C in a 25 mm pipe at 2 m/s gives a Reynolds number of 2 × 0.025 / 1.0e-6 = 50,000, while a 46 mm²/s oil in the same pipe at the same speed gives 1,087, which is laminar.
Changing between kinematic and dynamic viscosity
Kinematic viscosity is dynamic viscosity divided by density. If the dynamic viscosity is in mPa·s, which is the same as centipoise, and the density is in g/cm³, the quotient comes out directly in mm²/s. A mineral oil with density 920 kg/m³ and kinematic viscosity 46 mm²/s therefore has a dynamic viscosity of 46 × 10⁻⁶ × 920 = 0.04232 Pa·s, or 42.3 mPa·s. The conversion needs the density at the same temperature as the viscosity, and the units must match: using kg/m³ with a result in mm²/s without the 10⁻⁶ factor gives an answer that is a million times off.
Viscosity falls as temperature rises
Oils thin quickly on heating. A typical mineral ISO VG 46 hydraulic oil at 46 mm²/s at 40 °C is near 6.8 mm²/s at 100 °C, a drop to about 15 percent of the cold value. ASTM D341 charts let you interpolate between two measured points on a log-log scale. A hydraulic system running at 60 °C is thinner than the label grade implies, and one at 10 °C is far thicker, which affects pump start-up. Because of this behavior, a single mm²/s figure is incomplete without its temperature, and conversions between units do not change that.
Notation and mix-ups to avoid
The unit is written mm²/s, mm2/s or sq mm per second, and it is the same as cSt. Centistokes, symbol cSt, is a kinematic unit, while centipoise, symbol cP, is a dynamic one. Both appear in older datasheets, and mixing them produces errors proportional to density. The mm²/s unit is also not mm/s, which is a speed. Saybolt Universal Seconds are an efflux time scale with a nonlinear relation to viscosity, published in ASTM D2161, so they cannot be converted by a single factor. Keep the unit and the temperature beside every value.
Precision and checking
- Retain source viscosity precision.
- Keep mm² distinct from mm.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Kinematic viscosity converter
- Square millimeters per second to Square meters per second converter (kinematic viscosity)
- Square millimeters per second to Stokes converter (kinematic viscosity)
- Square millimeters per second to Square feet per second converter (kinematic viscosity)
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.