Measurement basis
The stored factor is 0.09290304 m²/s.
Definition conventions
Centistokes and mm²/s are numerically identical and remain familiar labels within the same quantity converter.
Conversion method
Multiply ft²/s by the area-per-time factor.
Reference equivalent of ft²/s
1 ft²/s = approximately 0.09290304 m²/s.
Recorded scale factors: 0.09290304 for ft²/s; 1 for m²/s.
Worked example
Known input: 10 ft²/s. Reference equivalent: 0.9290304 m²/s. The return conversion gives approximately 10 ft²/s.
The example uses the squared foot definition.
Common reference values
| Input (ft²/s) | Reference equivalent (m²/s) |
|---|---|
| 1 | 0.09290304 |
| 5 | 0.4645152 |
| 10 | 0.9290304 |
| 25 | 2.322576 |
| 50 | 4.645152 |
| 100 | 9.290304 |
Compare one ft²/s with other units
| Target unit | Equivalent of 1 ft²/s | Definition guide |
|---|---|---|
| Square meters per second (m²/s) | 0.09290304 | Read definition |
| Square millimeters per second (mm²/s) | 92903.04 | Read definition |
| Stokes (St) | 929.0304 | Read definition |
What an area per second measures
Square feet per second, written ft²/s, is a length squared divided by time. It is the US customary unit for kinematic viscosity, the ratio of dynamic viscosity to density, and it is equally used for diffusivities of heat and of dissolved substances. The foot in it is the international foot of exactly 0.3048 m, fixed by the 1959 yard and pound agreement and listed in NIST SP 811. Squaring that length gives 1 ft²/s = 0.09290304 m²/s exactly, so 1 m²/s equals 10.7639104167 ft²/s. The unit is not part of the SI. It appears mainly in American hydraulics, aerodynamics and process-engineering texts written in inch-pound units.
Links to stokes and centistokes
Because 1 ft²/s is 0.09290304 m²/s, it equals 929.0304 St, since one stokes is 10⁻⁴ m²/s, and 92,903.04 cSt, which is the same as 92,903.04 mm²/s. Site tools cover the direction you need: Square feet per second to Square meters per second converter (kinematic viscosity), Square feet per second to Stokes converter (kinematic viscosity), Square feet per second to Centistokes converter (kinematic viscosity) and Square feet per second to Square millimeters per second converter (kinematic viscosity). Going the other way, a 32 cSt oil is 32 × 0.0000107639104167 = 3.4444e-4 ft²/s. A heavy oil of 1,000 cSt is about 0.01076 ft²/s.
Reynolds number in inch-pound units
Pipe flow engineers use ft²/s in the Reynolds number, Re = V × D / ν, with velocity in ft/s and diameter in ft. Water at 68 °F has ν near 1.08e-5 ft²/s. With V = 5 ft/s in a 6 in (0.5 ft) pipe, Re is about 5 × 0.5 / 1.08e-5 = 231,000, well above the roughly 4,000 at which pipe flow is usually treated as turbulent. In SI units the same pipe, 1.524 m/s and 0.1524 m, with ν near 1.004e-6 m²/s, gives about 231,000 too. The Reynolds number is dimensionless, so it is unchanged by the unit system as long as every factor is converted consistently.
Typical values to keep in mind
Water at about 68 °F has a kinematic viscosity near 1.08e-5 ft²/s. Air at the same temperature is near 1.63e-4 ft²/s, about 15 times larger. Air is far less viscous in the dynamic sense, roughly 55 times less than water, but it is also about 800 times less dense, so the ratio of the two flips. That is why kinematic viscosity, not dynamic viscosity, sets how quickly momentum spreads in a flow. Lubricating oils run from around 1e-4 ft²/s for light grades to over 1e-2 ft²/s for heavy fuel oil. Seawater at 68 °F is near 1.13e-5 ft²/s, about 1.05 cSt. Water at 100 °F is near 0.68 centistokes, about 7.3e-6 ft²/s, so heating water by 32 °F lowers its kinematic viscosity by roughly a third, and heating oil changes it by far more.
Related quantities with the same dimension
Thermal diffusivity and mass diffusivity also have dimensions of length squared per time, so ft²/s describes them too. The Prandtl number, kinematic viscosity divided by thermal diffusivity, is dimensionless and sits near 0.71 for air, and the Schmidt number divides viscosity by mass diffusivity. These ratios only work if both quantities use the same unit, which is why textbooks tabulate air properties at 68 °F in a single system. Air at 68 °F has a thermal diffusivity near 2.1e-5 m²/s, about 2.3e-4 ft²/s, which gives a Prandtl number near 0.7.
From dynamic viscosity to ft²/s
In inch-pound practice dynamic viscosity is often in lbf·s/ft², which equals slug per foot-second, and density is in slug/ft³. Dividing gives ft²/s directly. For water near 68 °F, 2.09e-5 lbf·s/ft² divided by 1.94 slug/ft³ gives about 1.08e-5 ft²/s. The same relationship in SI units divides Pa·s by kg/m³ to give m²/s. Pound-mass based tables need a gravitational constant before they give the same answer, so check whether the data uses slugs or pounds-mass before dividing. Mixing the two produces a factor of 32.174 in the result. Oil data sheets often give dynamic viscosity in centipoise and specific gravity instead, and then ν in cSt is the centipoise value divided by the specific gravity, since 1 cP is 0.01 P and the density is in g/cm³. A fluid at 100 cP with specific gravity 0.9 therefore has 111 cSt, which is 1.2e-3 ft²/s.
Do not reuse the length factor
The conversion factor for ft²/s is the square of the foot to metre factor, 0.3048² = 0.09290304. Using plain 0.3048 changes the result by a factor of 3.28, because 1 / 0.3048 is 3.2808. An air value of 1.63e-4 ft²/s becomes 1.51e-5 m²/s with the right factor, but 4.97e-5 m²/s with the length factor. A similar slip confuses ft²/s with ft³/s, the volumetric flow unit often written cfs, and with ft/s, a speed. The numerator exponent is what separates them. One ft³/s equals 0.028316846592 m³/s.
Notation in sources
Sources write the unit as ft²/s, ft2/s, ft^2/s, sq ft/s or ft²·s⁻¹, and older tables sometimes give it as square feet per second without a symbol. The SI Brochure and NIST SP 811 describe derived units by their base-unit combinations, and any of these forms reduces to the same quantity. When reading a table, look for the temperature and the fluid beside the value, since kinematic viscosity changes with both. Rather than rounding aggressively, keep at least three significant digits through the calculation, because the Reynolds number and head-loss formulas amplify small errors in viscosity. ISO 3448 defines the viscosity grades by the mid-point kinematic viscosity at 40 °C, with a tolerance of plus or minus 10 percent. A ft²/s value of 1.5e-5 equals 1.39e-6 m²/s, or 1.39 cSt, which is a light fluid. Conversely, a 46 cSt hydraulic oil, a common ISO grade at 40 °C, is 4.95e-4 ft²/s.
Heat transfer and boundary layers
In boundary layer work the local Reynolds number is built from distance along the surface, Re = V x / ν. Air at 68 °F, with ν near 1.63e-4 ft²/s and a flow of 50 ft/s, reaches Re of about 3 x 10⁵ after one foot, 50 × 1 / 1.63e-4 = 306,800, near the range where a flat-plate layer commonly begins to turn turbulent. The same quantity ν divided by the speed gives a length scale: 1.63e-4 / 50 is 3.3e-6 ft, or 0.001 mm. Thermal engineers read ft²/s directly as how fast heat or momentum diffuses, since a diffusion distance grows as the square root of diffusivity times time. Tables for steam and refrigerants in inch-pound units also list ν in ft²/s.
Precision and checking
- Retain measured viscosity precision.
- Keep the square exponent.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Kinematic viscosity converter
- Square feet per second to Square meters per second converter (kinematic viscosity)
- Square feet per second to Centistokes converter (kinematic viscosity)
- Square feet per second to Square millimeters per second converter (kinematic viscosity)
- Square feet per second to Stokes converter (kinematic viscosity)
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.