MEASUREMENT & METHODS

Nanonewtons (nN): force unit guide

nN is the nano-prefixed force entry.

Measurement basis

Its reference factor is 10^-9 N.

Definition conventions

Gravity-derived factors use standard gravity of 9.80665 m/s². Ton-force means US short ton-force in the listed definitions.

Conversion method

Multiply nN by 10^-9 without early rounding.

Reference equivalent of nN

1 nN = approximately 1e-9 N.

Recorded scale factors: 1e-9 for nN; 1 for N.

Worked example

Known input: 10 nN. Reference equivalent: 1e-8 N. The return conversion gives approximately 10 nN.

The example preserves force on the reference scale.

Common reference values

Input (nN)Reference equivalent (N)
11e-9
55e-9
101e-8
252.5e-8
505e-8
1001e-7

Compare one nN with other units

Target unitEquivalent of 1 nNDefinition guide
newtons (N)1e-9Read definition
kilonewtons (kN)1e-12Read definition
dynes (dyn)0.0001Read definition
kilogram force (kgf)1.01971621298e-10Read definition
pound force (lbf)2.248089431e-10Read definition
kips (kip)2.248089431e-13Read definition
poundals (pdl)7.23301385121e-9Read definition
US short ton-force (US tonf)1.1240447155e-13Read definition

The smallest forces people routinely quote

A nanonewton (nN) is 10^-9 newton. The newton is the SI unit of force, defined as the force that gives a mass of one kilogram an acceleration of one meter per second squared, so 1 N = 1 kg·m·s⁻². The name newton was adopted by the 9th CGPM in 1948. A nanonewton is one billionth of that, small enough that gravity pulling on a 1 µg mass produces about 9.807 nN, using standard gravity of exactly 9.80665 m/s². The unit appears in atomic force microscopy, surface and adhesion studies, microelectromechanical systems and biophysics, where forces between a probe and a surface are far below what a kitchen scale could register.

Cantilevers, cells and charges

In an atomic force microscope, the force on a probe follows Hooke law, F = kx. A cantilever with a spring constant of 0.1 N/m deflected by 1 nm applies 0.1 nN, so typical imaging forces fall between tens of piconewtons and tens of nanonewtons. Cell and molecular adhesion measurements also lie in the nanonewton range, while single-molecule optical tweezers tend to work at piconewtons. Electrostatics gives another scale: by Coulomb law, two 1 nC charges 1 m apart exert F = kq1q2/r², about 8.99 nN with k near 8.9876 × 10^9 N·m²/C². Treat these as illustrations of scale rather than reference values, because real forces depend heavily on geometry, medium and instrument calibration.

Conversions to and from nN

One nN equals 0.000000001 N, 0.001 µN, 1,000 pN and 0.000001 mN. In the centimeter-gram-second system the dyne is exactly 10^-5 N, so 1 nN is 10^-4 dyn and 1 dyn is 10,000 nN. The pound-force is defined as exactly 4.4482216152605 N, which makes 1 nN about 2.248 × 10^-10 lbf, and the kilogram-force is exactly 9.80665 N, so 1 nN is about 1.0197 × 10^-10 kgf. The site Force converter works with newtons and kilonewtons, where kN = N × 0.001, and a nanonewton reading can be scaled by 10^-9 to reach newtons before using it. Intermediate steps through newtons are the simplest path, and they keep rounding errors out of the middle of a chain of conversions.

Force is not mass and not torque

A kilogram reading is not a force until it is combined with an acceleration. A balance that shows 3 µg is reporting mass, and the matching weight under standard gravity is 3 µg × 9.80665 m/s², or 29.42 nN. The same care applies in reverse. A force sensor in nanonewtons does not indicate how much mass a sample holds unless the force is gravitational and the local value of g is known. Local gravity varies by about 0.5 percent over Earth, which is far smaller than most nanonewton instrument uncertainties but still worth tracking in precision work. Keep also the difference between force and torque: a torque of 1 nN·m is a force of 1 nN acting at 1 m, and the two units cannot be added or interchanged.

Capillary pulls and tiny weights

Surface tension turns lengths into nanonewtons. Water at about 20 °C has a surface tension near 0.0728 N/m, so each micrometer of contact line carries a pull of 0.0728 × 10^-6 N, or about 72.8 nN. That is why a droplet can move or hold a micro-sized particle against its own weight. Gravity at this scale is small by comparison. A MEMS proof mass of 0.5 µg at 1 g of acceleration presses with 0.5 × 10^-9 kg × 9.80665 m/s², about 4.90 nN, which is what a force-sensing accelerometer element must resolve. Both numbers are illustrative calculations, and real devices add effects from geometry, contamination and temperature that shift the actual forces.

Cantilever stiffness mixed with nanonewtons

Many nanonewton calculations use a spring constant, which carries the unit newton per meter. A cantilever of 2 N/m deflected by 5 nm exerts 10 nN, and one of 0.05 N/m deflected by 20 nm exerts 1 nN. Deflections are read optically or capacitively in nanometers, so the unit pair nN and nm appears together in almost every force curve. Converting to base units first removes mistakes: 5 nm is 5 × 10^-9 m, and 2 N/m times that is 1 × 10^-8 N, which is 10 nN. A force curve usually also needs the sensitivity of the photodetector in nm per volt, which is measured on a stiff surface, so every nanonewton figure inherits two calibrations.

Reading nN and its neighbors on instrument screens

Force spectroscopy data is often displayed in nN, pN and µN on the same axis range, so reading the prefix matters. The symbol is nN, with lowercase n and uppercase N, and nN differs from nM (nanomolar) and nm (nanometer) in the same data file. Surface tension and spring constants use newtons per meter, written N/m or mN/m, and these share the newton in their names. A spring constant of 0.1 N/m is 100 mN/m, and the force at a given deflection is the stiffness times the distance, a step that mixes N/m and nm into nN. Keep the three together in one equation and convert each to base units first: N/m times m gives N.

Calibration and uncertainty

A force value in nanonewtons is the product of a calibration, so its accuracy is limited by how the sensor was calibrated. Atomic force microscope cantilevers are often calibrated by thermal-noise or reference-cantilever methods, and even carefully calibrated spring constants carry uncertainties of ten percent or more. A force of 2.00 nN may therefore be 2 nN within a wide range, and expressing it as 2.000000 × 10^-9 N adds only zeros. For reporting, keep the same number of significant figures as the source, choose the prefix that keeps the number between 1 and 1,000, and give the calibration method when comparing results across laboratories. Comparisons between instruments only make sense when both calibrations are traceable to the same reference.

Choosing between nN, µN and pN

Pick a prefix so the number needs no leading zeros: 0.4 nN is better quoted as 400 pN, and 3,500 nN as 3.5 µN. For forces that are conventionally reported in newtons, such as the weight of an object or the load on a structure, nanonewtons are never used, and a value in nN means the context is microscopic. When you convert, scale by powers of 1,000 and keep significant figures: 12.5 nN becomes 0.0125 µN, 12,500 pN and 1.25 × 10^-8 N. Put the unit after a space, write the symbol nN without a period, and give the quantity name when the unit could be read as another, since N alone could also mean newtons in a torque or pressure compound.

Precision and checking

  • Retain measured force resolution.
  • Keep nN attached to the number.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →