Heating values are written in MJ
Fuel data sheets give energy content in megajoules per kilogram, per liter or per cubic meter, and gas bills in Australia list consumption in megajoules. A national balance or a project report states the total in terajoules. To translate between the two, a reader multiplies a fuel quantity by its heating value in MJ and then needs the total in TJ, or goes the other way and takes a TJ target back to a quantity of fuel. This page handles the unit step: it multiplies a terajoule value by one million and returns megajoules.
Six places to the right
Tera is 10^12 and mega is 10^6, so one terajoule is 10^6 megajoules, and the formula is MJ = TJ × 1,000,000. The factor is exact, given by the SI Brochure prefixes and listed in NIST SP 811. By hand, shift the decimal point six places right: 0.25 TJ is 250,000 MJ and 0.0036 TJ is 3,600 MJ. In reverse, divide by a million, so 840 MJ is 0.00084 TJ. The usual slip is to confuse mega with giga, which would give a factor of 1,000 error, so confirm the prefix on the source label before you convert. In an outage report, 2.5 TJ is 2,500,000 MJ, a figure with six more digits than the TJ entry. When a table lists lines in MJ and a total in TJ, convert each line first and then sum, and check the sum against the printed total.
Ten million megajoules for 10 TJ
The page opens with 10 TJ and returns 10,000,000 MJ. If one liter of diesel holds about 36 MJ, an illustrative round figure, the default corresponds to roughly 278,000 liters. A household that burns 20 GJ of gas, which is 20,000 MJ, in a winter uses 0.02 TJ, so the default equals the use of 500 such households. Smaller consumers fit too: a bakery oven line that uses 1,500 MJ a day over 300 days uses 450,000 MJ a year, which is 0.45 TJ. These comparisons depend on assumed heating values and give only an order of magnitude. The converter itself supplies just the unit relation, and fuel suppliers publish the heating value of the product that you buy. Diesel, heating oil, propane and wood all have different values, so the quantity needed for 1 TJ changes with the fuel.
Wood pellets and biomass
Wood pellets are commonly rated near 17 MJ per kilogram on a delivered basis, though the figure depends on moisture and the standard used. At 17 MJ/kg, one terajoule, which is a million megajoules, equals about 58,824 kg, or roughly 59 tonnes of pellets. A household boiler that burns 4 tonnes in a winter uses about 68,000 MJ, which is 0.068 TJ. Biomass reports often quote tonnes, and an energy planner converts them to megajoules to compare with gas and oil. Always check whether the heating value is for dry or as-received fuel, because moisture can change the figure by a large margin. For a 0.5 TJ target, pellets at 17 MJ/kg need about 29,412 kg.
Natural gas billed in megajoules
In Australia, gas bills list usage in megajoules, and a typical household might use a few thousand megajoules in a month. A bill showing 4,500 MJ in a billing period corresponds to about 1,250 kWh of heat energy, since one kWh is 3.6 MJ. In terajoules, 4,500 MJ is 0.0045 TJ. A retailer converts volume to energy using a heating value that is stated on the bill. If you want to check a bill, multiply the metered volume by that heating value and compare it with the printed energy. This page converts the total, and a bill needs the factor from the retailer.
Megajoules against kilowatt-hours
One kilowatt-hour equals 3.6 MJ, so a megajoule is about 0.2778 kWh. A figure of 10,000,000 MJ is about 2,777,778 kWh, and 36 MJ is 10 kWh. People move between the two units when they compare gas, which is often billed in MJ, with electricity, which is billed in kWh. For a heat comparison, remember that a heat pump delivers more heat than the electricity it takes in, while a gas boiler delivers less than the fuel it burns. This page converts raw energy and leaves efficiencies to a different calculation. An electric kettle drawing 2.4 kW for 5 minutes uses 0.2 kWh, which is 0.72 MJ.
Food energy in MJ per day
Nutrition science papers state daily energy requirements in megajoules. An adult might need around 8 to 10 MJ per day, which corresponds to about 1,900 to 2,400 kcal. At 8.4 MJ per day, a population of one million needs 8.4 TJ a day, so the default of 10 TJ covers about 1.2 days of food energy for them. The need varies with age, size and activity, so the figures here are illustrative. The converter does not estimate requirements. A meal of 3.2 MJ is 3,200 kJ, or about 765 kcal. It only expresses a daily sum in a unit that fits a national total.
Mixing up M, m and G
Mega uses an uppercase M, milli uses a lowercase m, and giga uses an uppercase G. A column of MJ that contains a value typed in mJ is wrong by a factor of 10^9. Some software exports lowercase everywhere, so check headers before using a large data file. In a lab notebook, write the full unit name when in doubt. The labels on this page show both the name and the symbol of the unit so that a mismatch with the source stands out. The factor of one million is fixed, so errors almost always come from reading or typing the unit. On a sensor spec sheet, 5 mJ is five thousandths of a joule and has nothing in common with 5 MJ, which is 5,000,000 J.
From a terajoule target to cubic meters of gas
To estimate a fuel quantity for a target in terajoules, convert to megajoules here, then divide by the heating value in megajoules per unit of fuel. A target of 0.5 TJ with natural gas at 38 MJ per cubic meter needs about 13,158 cubic meters. The estimate ignores combustion efficiency, so a boiler with 90 percent efficiency must burn more gas than the useful heat figure implies. The converter provides the first step, and the heating value, the efficiency and the quality of the input data decide how far the estimate can be trusted.