CGS data, imperial formulas

A fluid property taken from a textbook or an older report in stokes sometimes has to feed a calculation in feet, pounds and seconds. A pipe-flow estimate in US units uses velocity in feet per second and diameter in inches or feet, so viscosity must be in square feet per second. This page converts stokes directly, so the CGS figure does not have to go through meters first. It changes only the unit and keeps the physical quantity, kinematic viscosity, unchanged. The temperature of the original value still matters, and the page cannot supply it. Most CGS tables give the temperature in a footnote or a header row, so copy it along with the number when you move a value into a design file. A value that has lost its temperature is much less useful than one that carries it.

From centimeters to feet, squared

A centimeter is 1 divided by 30.48 of a foot, about 0.0328084 ft. Squared, that gives 0.00107639104167 ft² per cm². Since 1 St is 1 cm²/s, one stokes equals 0.00107639104167 ft²/s. The default of 10 St returns 0.0107639 ft²/s. Another route is through the SI unit: 1 St is 10^-4 m²/s, and each m² is 10.7639 ft². Both routes give the same factor, which makes a good self-check. The seconds are the same on both sides and need no adjustment, and the factor is exact in definition. Keeping the two routes in mind lets you check a stored factor in a spreadsheet at a glance.

Syrups and heavy oils

Stokes values above 1 describe thick liquids. A syrup or heavy oil at 10 St is 0.0107639 ft²/s, which looks tiny in imperial terms even though the fluid is slow-moving. Imperial numbers are small because the square foot per second is a large unit relative to everyday fluids. A process engineer pumping a thick liquid in a plant that uses US units can enter the stokes figure and get the value for a formula, without first rebuilding the property in meters. The page cannot tell how viscosity will change as the liquid cools, so use the figure for the operating temperature when you plan equipment. Thick liquids can fall by a factor of ten or more over a modest rise in temperature, which changes pump sizing and line losses substantially.

A VG 46 oil

An oil of 0.46 St, which is ISO VG 46, converts to 0.000495140 ft²/s. An oil of 0.68 St, VG 68, gives 0.000731946 ft²/s. These are the imperial figures a US manual might list for those grades at 40 °C. The ratio between them is the same as between the stokes values, 68 to 46, since the page multiplies by a constant. If you compare two oils, convert both with the same factor and check the ratio. A mismatch shows that one of the entries was mistyped. Rounding each result to three digits before taking the ratio would hide such an error, so compare the full-precision outputs.

Water and thin liquids

Water near 20 °C is about 0.01 St, which converts to 0.0000107639 ft²/s. The value is a standard reference for imperial tables, which often list water at around 1.08 × 10^-5 ft²/s. Using that as a marker, a converted result of 10^-5 means thin, free-flowing liquid, 10^-4 means a light oil, and 10^-3 or larger means a heavy oil. When a conversion lands far from the expected family of fluids, look for a misplaced decimal first, because the numbers contain several leading zeros and are easy to miscopy. Copy the digits from the output field instead of reading them off the screen and retyping them.

A Reynolds number in a 1.5 inch line

Take VG 68 oil at 0.68 St, which converts to 0.000731946 ft²/s. Flowing at 2 ft/s in a 1.5 inch line, 0.125 ft in diameter, it has a Reynolds number of 2 × 0.125 / 0.000731946, about 342. The flow is laminar, and a laminar friction formula applies. Had the viscosity been entered in stokes while the other terms were in feet, the result would have been meaningless by a factor of nearly a thousand. The conversion is a necessary step to keep all quantities consistent, and the same applies to any correlation with a viscosity term. Laminar flow in such a line is also the regime in which the oil temperature has the greatest effect on pressure drop.

Gas diffusion values in cm²/s

Gas diffusion coefficients in air are often listed in cm²/s, with typical values near 0.1 to 0.3. A value of 0.15 cm²/s equals 0.15 St numerically and converts to 0.000161459 ft²/s. The page is for kinematic viscosity, but the arithmetic of the unit change is the same for any quantity in cm²/s, so a researcher moving a diffusion coefficient into an imperial model uses the same factor. Keep the quantity name in the label, since a diffusivity and a viscosity with the same value are different properties and are used in different formulas.

Common slips

Two errors recur with this conversion. The first is using 0.0929, the number of square meters in a square foot, instead of the correct factor for square centimeters, which gives a result that is off by a factor of 10,000. The second is applying a linear factor like 0.0328 to an area-type unit, which gives about 0.33 for 10 St instead of 0.0108. Both slips are easy to catch with the size estimate that follows. A quick estimate helps: a stokes is a tiny area per second, about a thousandth of a square foot, so 10 St should land near 0.01 ft²/s. If your result misses that by a factor of ten or more, recheck.

Reversing and precision

To go back, divide ft²/s by 0.00107639104167 or use the reverse page. An answer of 0.0107639 ft²/s returns 10 St. The page keeps full precision internally and rounds for display to 12 significant digits, so a round trip can differ in a far decimal. Quote three or four significant digits and give the temperature, since a viscosity figure without one cannot be matched to an equipment limit. For documentation, show the stokes value as the source and the imperial value as a working figure, so that a reader who wants to verify the conversion starts from the original number.