Optical power meters and laser labels

Fiber technicians, lab staff and hobbyists meet milliwatts on laser pointers, transceivers and transmitters, and they meet picowatts on the low ranges of an optical power meter or in a detector datasheet. A person who sets a measured received level beside the transmit power, or who fills a link-budget table, needs one unit. This page divides a picowatt value by 10^9 and returns milliwatts. It also converts back, so a transmit power in milliwatts can be expressed in picowatts for a sheet that works at the low end. Because the two units are nine powers of ten apart, small inputs give answers with an exponent, which keeps the digits readable.

Nine places and a billion

Pico is 10^-12 and milli is 10^-3, so one milliwatt equals 10^9 picowatts, a billion. The formula is mW = pW × 1e-9. Both prefixes are defined in the SI Brochure, and the factor is a defined number. Moving the decimal point nine places to the left does the conversion by hand. A reading of 250 pW is 2.5 × 10^-7 mW, and 5,000,000,000 pW is 5 mW. If the answer comes out larger than the input, the unit order is reversed. Going through the watt gives the same result: divide by 10^12 to reach watts, then multiply by 1,000 to reach milliwatts, which together make the factor of 10^-9.

What 1e-8 mW stands for

The default of 10 pW gives 1 × 10^-8 mW. The page may show a binary rounding tail, such as 9.999999999999999e-9, and the value to report is 1e-8 mW. In decibels relative to a milliwatt, the same level is -80 dBm. That is a faint signal, comparable to what a radio receiver works with near its sensitivity limit. The example shows how much smaller a picowatt reading is than the milliwatt output of a typical transmitter, a ratio of a hundred million to one in this case. When you copy the result into a document, keep the exponent form, since a string of eight zeros after the decimal point is easy to lose or to count wrongly.

Laser classes in milliwatts

Visible laser pointers sold to consumers are usually limited to Class 2 or Class 3R. Under IEC 60825-1, a visible Class 2 laser stays at or below 1 mW, which is 10^9 pW, and a Class 3R visible laser stays at or below 5 mW, or 5 × 10^9 pW. A stray reflection that a sensitive detector sees may be a few hundred picowatts, millions of times weaker than the beam itself. Eye safety depends on the class, the wavelength, the beam size and the exposure time, so the label and the manufacturer instructions govern the use of any laser. The converter only restates the numbers in another unit and makes no statement about safety.

Fiber links, dBm and picowatts

Optical receivers and transmitters are specified in dBm. A level of 0 dBm is 1 mW. A level of -30 dBm is 0.001 mW, which is 10^6 pW. A level of -60 dBm is 10^-6 mW, or 1,000 pW, and -70 dBm is 10^-7 mW, or 100 pW. Technicians convert these to linear units when they compare a meter reading in nW or pW with a datasheet written in dBm. The page has no decibel input, so convert dBm to milliwatts with P = 10^(dBm/10), then enter the milliwatt value. A reading of -70 dBm and a result near 100 pW agree, which makes a handy cross-check between the two ways of writing a level.

A loss budget in linear terms

A loss of 3 dB halves the power, and a loss of 10 dB leaves one tenth. If a transmitter sends 0 dBm, which is 1 mW or 10^9 pW, and the link loses 20 dB, the receiver sees 0.01 mW, or 10^7 pW. A loss of 50 dB brings the level to 10^-5 mW, which is 10,000 pW. These examples are illustrative, and a real link has connectors, splices and aging in it. Linear units make some sums easier, for instance when two sources add, while decibels make cascades of gains and losses easy to add up. The page helps with the linear side, and a technician uses whichever form the tool at hand reports.

Range switches and auto-ranging meters

Optical and RF power meters show readings with units that change as the range changes. A display that jumps from nW to µW or from mW to W can hide a factor of 1,000 if the unit label is small. Writing down the unit with each reading avoids the problem. If you enter a reading of 250 and mean picowatts, the page returns 2.5e-7 mW, and if you accidentally treat the number as nanowatts, the answer would be a thousand times larger. A quick sanity check is to compare the converted value with the transmit level or the noise floor you expect, and to repeat the measurement on a second range if the two disagree.

Wavelength and calibration stay outside the page

A power meter reading depends on the detector response at the wavelength in use, on calibration and on the connector. The page converts a power from picowatts to milliwatts without knowing any of that. It does not convert decibels, apply a wavelength correction or estimate the bit error rate of a link. For laser safety, optical test and radio compliance, rely on the instrument manual, the applicable standard and a qualified person. Since the factor of 10^-9 is a defined number, a surprising result almost always comes from a swapped pair of units, a level that was in dBm and not in a linear unit, or a digit lost when the value was typed.

Short-range radios on the same scale

Bluetooth radios come in three power classes. Class 1 transmits up to 100 mW, Class 2 up to 2.5 mW and Class 3 up to 1 mW. In picowatts those are 10^11, 2.5 × 10^9 and 10^9. A receiver at the far side of a room may see a level near 100 pW, so the gap between what is sent and what arrives is a factor of ten million or more, shared across distance, walls and antenna gain. Entering a class limit in milliwatts and picowatts side by side gives a feel for that gap. The numbers describe maximum transmit power and not typical use, and real devices usually run well below the limit.