Light touch forces are quoted in millinewtons

Millinewtons describe forces at the edge of what a person can feel: the pressing force of a contact probe, the return force of a small spring, the pull of a wire bond test or the tip force of a stylus. Piconewtons describe forces nine orders of magnitude smaller, in the range of single molecules. A reader who sets a probe force from a manufacturer beside a molecular force from a paper needs both in one unit. This page divides the piconewton value by one billion and returns millinewtons, with an exponent when the result is small, which is almost always the case for molecular inputs.

One billion piconewtons per millinewton

Pico is 10^-12 and milli is 10^-3, so a millinewton contains 10^9 piconewtons. The formula is mN = pN × 10^-9. The prefix definitions are in the BIPM SI Brochure and NIST SP 811, and the factor is exact. Move the decimal point nine places to the left: 2,000,000,000 pN is 2 mN, and 750,000 pN is 0.00075 mN. A route through three steps of 1,000 can serve as a check: piconewtons to nanonewtons, to micronewtons, to millinewtons. If your hand result and the page disagree, count the places again, since a slip of three places changes the answer by a thousand and looks plausible.

A reading of 1e-8 mN

With the default of 10 pN the page shows about 1 × 10^-8 mN, which the software prints as 9.999999999999999e-9 because of binary rounding. Read it as 0.00000001 mN. A 6 pN force is 6 × 10^-9 mN, and a 100 pN force is 1 × 10^-7 mN. Those are not forces that any touch sensor registers, and the conversion mainly serves as a scale statement. Dividing a probe force of 1 mN by a 100 pN trap force gives 10^7, ten million traps pulling together, which expresses the gap more clearly than either small decimal can. The same division tells a product tester how many micro-scale events a switch spring represents: a spring that returns 0.2 mN is returning 2 × 10^8 pN, and the force is the sum of countless atomic interactions inside the metal, none of which you would ever measure on its own.

A keyboard switch in millinewtons

Mechanical keyboard switches are described by an actuation force in grams-force, and values around 45 gf are common. One gram-force is 9.80665 mN, so 45 gf is 441.3 mN, or 0.4413 N. In piconewtons that is about 4.413 × 10^11 pN. The figure is an everyday anchor for the millinewton scale: pressing a key is hundreds of millinewtons, a light probe contact is a few millinewtons and a molecular motor is about 10^-9 mN. Use the page to convert a manufacturer value from gram-force to newtons first, then to the unit of your choice, when a product sheet is the only source.

Probe and contact forces in testing

Contact probes used in electronics testing and in surface profilers press on a sample with a controlled force, often between 0.1 and 10 mN. A stylus force of 1 mN equals 10^9 pN. Setting the force too low gives a poor electrical contact, and setting it too high can scratch a soft coating. Wire bond pull tests report failure forces in millinewtons or in grams-force for fine wires. A reading of 80 mN is 8 × 10^10 pN, and is about 8.2 gf. The conversion keeps these values comparable when a specification and a test report use different units.

Surface tension and small springs

Surface tension has units of force per length, and the common unit mN/m is numerically equal to dyn/cm. Water near room temperature has a surface tension close to 72 mN/m. A force per length is not a force, so it cannot be converted by this page without a length, but a tensiometer that measures the pull on a plate of 20 mm wetted perimeter at 72 mN/m registers 72 × 0.02 = 1.44 mN. That is the kind of force a sensitive balance reads, and 1.44 mN is 1.44 × 10^9 pN. The example is illustrative and ignores contact angle details that a real measurement must handle. Cleaning and coating work uses the same quantity: a solution with 30 mN/m wets a surface more readily than water at 72 mN/m, and the surface tension figure on a product data sheet is the one to compare, not a force in millinewtons without a length.

Millinewtons back to piconewtons

Choose millinewtons as the From unit and piconewtons as the To unit. A force of 0.8 mN is 8 × 10^8 pN, and 3 mN is 3 × 10^9 pN. These are long numbers, so a report usually keeps millinewtons and micronewtons for touch forces and uses piconewtons only for molecular ones. When you compare two forces in a ratio, put both in the same unit first. The ratio of 3 mN to a 10 pN force is 3 × 10^9 / 10 = 3 × 10^8, three hundred million, a statement that needs no further explanation.

Case, symbols and precision

A capital M is mega and a lowercase m is milli, so MN and mN differ by 10^9. A force listed as 5 mN is a light push, while 5 MN is a heavy industrial load. A copy and paste that changes the case changes the meaning without any visible warning. Quote converted results with two or three significant figures, since probe forces are rarely known better than a few percent. The conversion factor is exact and adds no error, and any long tail of digits that a program prints is binary rounding, to be trimmed before the number goes into a report.

Zero the probe before trusting a low-range reading

A force typed in piconewtons is restated in millinewtons, and no probe or balance logic is applied. It does not choose a probe force that is safe for a sample, calibrate a balance or interpret a surface tension measurement. Those steps depend on the instrument, the material and the standard method for the test. Use the manufacturer documents and the relevant test method for such decisions, and treat figures in this article as illustrations of scale. Before trusting any reading, check that the probe was zeroed with no load and that the stated force range covers the value you read, since a gauge used near its lowest range can carry an error that is large next to the number shown. The converter keeps the powers of ten consistent between a specification in millinewtons and a molecular force in piconewtons.