Kips in structural drawings

In the United States, structural engineers state beam reactions, column loads and anchor capacities in kips, where one kip is a thousand pounds-force. Material testing laboratories that work with U.S. customers often report machine capacities in kips as well. Researchers who measure forces at the nanoscale work in piconewtons. Comparing a small test specimen with a full-size member, or explaining the scale of a testing program, calls for a conversion across more than fifteen orders of magnitude. A student writing a report on testing at several scales, from single molecules through coupons to full members, will meet kips, kilonewtons and piconewtons in the same chapter. This page converts piconewtons into kips, and it displays small results in scientific notation so that a missing zero cannot hide in a long decimal.

How a kip is defined

A kip is 1,000 lbf, and the pound-force is defined from the avoirdupois pound of 0.45359237 kg and standard gravity of 9.80665 m/s², which gives 1 lbf = 4.4482216152605 N. A kip is therefore 4,448.2216152605 N, or about 4.4482 kN. In piconewtons that is 4.4482216 × 10^15 pN, and the page uses the reciprocal, kip = pN × 2.248089431 × 10^-16. NIST SP 811 gives the pound-force factor. The word kip comes from kilo and pound, and the symbol is kip or k, with the plural kips. Drawings and design codes use it in lists next to units such as kip-ft for moments and ksi for stress.

Reading 2.248e-15 kip

The default of 10 pN returns 2.248 × 10^-15 kip. A 100 pN force is 2.248 × 10^-14 kip, and a 1,000 pN force, one nanonewton, is 2.248 × 10^-13 kip. The value is far too small to measure in a structural context, and the conversion serves as a statement of scale. If you want to put a figure next to a column load, divide the load by the converted value to see how many molecular forces it contains. The page returns the digits you need for that division, and the exponent tells you the order of magnitude of the answer.

A column load in piconewtons

Consider an illustrative column load of 20 kips on a footing. In newtons that is 20 × 4,448.2216 = 88,964.43 N, or about 89 kN, and in piconewtons it is 8.896 × 10^16 pN. A wood stud carrying 2 kips, which is 8.896 kN, comes to 8.896 × 10^15 pN. These numbers give a feel for the gap between a framing member and a molecular motor that produces 6 pN. The ratio for the 20-kip load is about 1.5 × 10^16, which means a single stud supports a force equal to that many motors pulling at once. The design of the member itself follows the building code and calculations by a licensed engineer. Load tables for lumber and steel show allowable values in kips or pounds, and the unit on the table is the first thing to read. A number of 2.0 in a column headed kips is 2,000 lbf, and a number of 2.0 in a column headed lbf is a thousand times smaller, which would not carry even a light fixture.

Pounds-force, kips and kilonewtons

Engineers move between units all the time. One kip is 1,000 lbf and 4.4482 kN, so 10 kips is 44.482 kN. A load listed as 25 kN is about 5.62 kips, since 25 / 4.4482 = 5.62. A lifting device marked 8 kips is rated for about 35.6 kN. When reading data from a mixed-unit project, make sure the unit label stays attached to each number, because a drawing in kips and a spreadsheet in kilonewtons share many of the same digits without sharing a scale. A conversion check with the factor 4.4482 catches a transposed unit at once. In a shared file, state which unit each tab uses, and avoid copying a number from one tab to another without carrying the unit with it. Many errors in mixed-unit work come from a figure that was right in its original sheet and wrong in the sheet it was pasted into.

From kips to piconewtons

Choose kips as the From unit and piconewtons as the To unit. One kip is 4.4482216 × 10^15 pN, and a half kip, which is 500 lbf, is 2.2241108 × 10^15 pN. These values appear in a comparison and do not belong in a design file, where kips, kilonewtons or newtons are the working units. If a spreadsheet stores forces in piconewtons for a nanoscale experiment and in kips for a structural test, add a column that states the unit explicitly and write the conversion factor in a note, since a cell with only a number gives the next reader no way to detect a unit error.

Mistaking kip for lbf

A frequent slip is to read a value in kips as pounds-force, which understates a force by a factor of one thousand. Drawings sometimes write loads as 12k, and an unwary reader who drops the k reads 12 lbf instead of 12,000 lbf. The reverse error is equally costly. In a spreadsheet, a column header that says kip prevents it. The piconewton scale makes the confusion harder to notice, because both numbers look absurdly large or small anyway. Write the unit next to every figure and check one value by hand against the factor 4,448.22 N per kip.

Significant figures

Structural loads on drawings are usually rounded to three significant figures at most, and a laboratory force in piconewtons to two. A converted value should have no more digits than the less precise input. Reporting 2.25 × 10^-15 kip for the default is enough. The factor itself is exact within the definitions, and the extra digits that a program prints, such as 2.2480894309971047e-15, come from binary arithmetic. Round before the number goes into a report, and keep the full value only inside a longer calculation.

Load factors and member checks come from the design code

A piconewton figure reaches kips on this page as a plain conversion. It does not check a load path, apply load factors or combinations from a code, or judge whether a member is adequate. Those steps follow standards such as ASCE 7 and the material design codes, and they are work for a licensed engineer. Use the converter to keep units straight when you read or write documents that mix piconewtons, newtons and kips. Never size a structural member from a converted number alone.