Forces on one molecule at a time
Piconewtons are the working unit of single-molecule biophysics. Optical tweezers, magnetic tweezers and atomic force spectroscopy pull on a strand of DNA, a protein or a motor molecule and report the force in pN. A paper may give a stretching force in piconewtons while a calibration note for the instrument is written in newtons or nanonewtons, so the two have to be placed on one scale. This page multiplies a newton value by 10^12 and shows the result in pN. It suits students writing up a lab course, researchers checking a conversion in a methods section and anyone who finds a long string of twelve zeros hard to read.
65 pN written as 0.000000000065 N
Pico is 10^-12 under the SI, so pN = N × 1,000,000,000,000 and the factor has no rounding. By hand, the decimal point moves twelve places to the right: 0.000000000065 N is 65 pN, and 0.002 N is 2,000,000,000 pN. The conversion is easier in two steps through the nanonewton, because one newton is 10^9 nN and one nN is 1,000 pN. A reading of 1 nN converts to 1,000 pN on this page. Newtons to piconewtons always makes the number larger, so a smaller answer means the units were picked in the wrong order. A trap that holds a bead with 5 pN exerts 0.000000000005 N, which is why papers quote the piconewton value.
Ten newtons is ten trillion piconewtons
The default of 10 N returns 10,000,000,000,000 pN, which is 1 × 10^13 pN. The value is only a test of the factor, since no single-molecule experiment applies anything close to ten newtons. For scale, ten newtons is about the weight of a one-kilogram bag of sugar. A force that fits this unit is a few piconewtons to a few hundred, and the matching value in newtons has ten or eleven zeros after the decimal point. Scientific notation keeps these numbers manageable in a table: write 1 × 10^13 pN rather than a row of thirteen digits, and attach the unit symbol so that readers do not mistake the figure for newtons.
Motor proteins and stretched DNA
Reported forces in this field give a feel for the unit. A kinesin motor walking along a microtubule is reported to stall at roughly 6 pN, and a DNA molecule held in an optical trap is reported to undergo its overstretching transition near 65 pN. In newtons those are 6 × 10^-12 N and 6.5 × 10^-11 N, which is 0.0000000000065 N for the second. The page returns 65 pN when you enter 0.000000000065 N, and 6 pN for 0.000000000006 N. These values come from experiments with specific buffers and temperatures, and papers differ by a pN or two, so use the figure from your own source rather than a rounded number from memory.
Trap stiffness times displacement
An optical trap acts like a spring, and its force is the stiffness multiplied by the displacement of the bead from the trap center. A stiffness of 0.1 pN/nm with a displacement of 100 nm gives 10 pN. This is an illustrative setting, and real traps are calibrated one by one. If you want the value in newtons for a formula, the page converts 10 pN to 0.00000000001 N, which is 1 × 10^-11 N. The multiplication of stiffness and displacement happens outside the page, and the converter handles only the unit. Report the calibration method next to the force, because the stiffness often carries an uncertainty of several percent and can change with the laser power or the bead size.
A nanogram placed on a scale
To picture a piconewton, think of weight. A mass of one nanogram presses down with about 9.8 pN on Earth, since 10^-12 kgf converts to 9.80665 pN at standard gravity. A typical mammalian cell has a mass of around a nanogram or a few nanograms, so its weight is on the order of ten piconewtons. That makes the forces in cell and molecule experiments comparable to the weight of the object under study, and the comparison explains why such instruments need vibration isolation and temperature control. The weight calculation uses standard gravity, which differs from the local value by a fraction of a percent and does not matter at this level of precision.
Stepping between pN, nN and µN
The units of small force step by 1,000. One micronewton is 1,000 nN, and one nN is 1,000 pN, so a micronewton is 1,000,000 pN. When an instrument manual lists a range in µN and a paper reports results in pN, converting both to one unit makes the comparison clear. An input of 5 µN, entered with micronewtons as the source and piconewtons as the target, returns 5,000,000 pN. A range of 250 pN is 0.00000000025 N, or 2.5 × 10^-10 N. Choose the unit that keeps the number between 1 and 1,000 in your tables, and keep a single unit per column so that the eye can scan down it.
Thermal noise sets the floor
At room temperature every small object is jostled by thermal motion, and the thermal energy is about 4.1 pN·nm. A force of a few piconewtons acting over a nanometer is comparable to that energy, which is why measurements at this scale need averaging and careful calibration. A reading of 0.5 pN may sit inside the noise of the trapped bead, even though the display shows several digits. The converter does not reduce noise or improve the measurement. It reports the same force in a different unit. When you quote a very small force, state the bandwidth, the averaging time and the uncertainty, because the number alone says little about how well it was measured.
Writing pN with a lowercase p
Calibrating a trap, deriving a force from a displacement, estimating an energy and checking whether an experiment is within the range of an instrument are separate tasks, as is deciding how many digits are meaningful. Use the protocol of your instrument and the methods described in the paper you are working from. If you publish a number, give the unit as pN with the correct case, since a capital P would stand for peta and change the value by a factor of 10^27. The factor itself is fixed by the SI prefixes, so any difference between two sources lies in the measurements.