Forces measured at the nanometer scale
Nanonewtons belong to instruments that touch surfaces with a sharp tip. An atomic force microscope presses a cantilever against a sample and reports forces on the order of nanonewtons, and a nanoindenter pushes a diamond tip into a thin film while recording load. Papers and lab notebooks in these fields quote forces in nN, while a calibration weight or a spring constant may be written in newtons. This page multiplies the newton value by one billion and returns the answer in nN, so a reference value and a result from the instrument can be compared directly. The factor is large, and writing it by hand invites errors in the number of zeros.
0.000002 N as 2,000 nN and 0.0000005 N as 500 nN
In the BIPM SI Brochure nano is 10^-9, so nN = N × 1,000,000,000 and nothing is rounded. The decimal point moves nine places to the right: 0.000002 N is 2,000 nN, and 0.0000005 N is 500 nN. Many people go through the intermediate unit. One newton is 1,000,000 µN, and one µN is 1,000 nN, which gives 10^6 times 10^3, or 10^9. Both routes agree on this page for any input. Reading the answer in groups of three digits makes a missing zero easy to spot. A result below the input is a sign that nanonewtons were chosen as the source. Writing the exponent beside the result, for example 2 × 10^3 nN, avoids long strings of zeros in a report.
Ten newtons as 1 × 10^10 nN
The default of 10 N returns 10,000,000,000 nN, which is ten billion nanonewtons or 1 × 10^10 nN. This is far outside the range of any nanoscale instrument, so the default works only as a test of the factor. A force that fits the unit is a few hundred nanonewtons, such as 0.0000005 N, which becomes 500 nN. In a report, scientific notation is usually easier to read than a string of ten digits. Pick the unit that leaves the number between 1 and 1,000: 500 nN is clearer than 0.5 µN or 0.0000005 N, and the page can restate a value in any of these steps.
One microgram on a cantilever
To get a feel for a nanonewton, think of weight. A mass of one microgram presses with about 9.8 nanonewtons on Earth, using standard gravity of 9.80665 m/s². That is a tiny load, comparable to a speck of dust on a sensor. A mass of 0.0000001 kgf, which is one tenth of a milligram, converts to 980.665 nN. Researchers who calibrate a cantilever with small known weights or compare the weight of a sample with the force on the tip use this scale. Real measurements also face adhesion, capillary forces from water films on a surface and electrostatic charge, so the weight of a sample is only one contribution.
Atomic force microscopy in nN
In contact-mode imaging the force between tip and sample is held at a set value, often described in nanonewtons, and soft samples such as polymers or cells need smaller values than hard crystals. The force is the product of the cantilever spring constant and its deflection. A cantilever of 0.1 N/m deflected by 100 nm exerts 10 nN, so a setpoint written in nN can be checked against a calibration in newtons. The page covers only the unit conversion, so the spring constant and the deflection sensitivity must come from your own calibration. Always record the force with its uncertainty, since calibrations of spring constants carry errors of ten percent or more.
Back to newtons
To change a nanonewton reading into newtons, set nanonewtons as the source and newtons as the target. A reading of 75 nN is 0.000000075 N, which is 7.5 × 10^-8 N, and 2,500 nN is 0.0000025 N. The page divides by one billion, so the decimal point moves nine places to the left. For a table of results, millinewton or micronewton units may be easier than newtons, since a long string of zeros hides the size of the number. Whichever unit you pick, write the symbol with the value, and write the Greek letter correctly when you use micro, since mN, µN and nN each stand for a factor of 1,000 apart.
A ladder of steps of 1,000
The page lists newtons, millinewtons, micronewtons and nanonewtons beside the larger units, and each is a thousand times smaller than the one before. One mN equals 1,000 µN, and one µN equals 1,000 nN, so one mN equals 1,000,000 nN. Keeping that step of 1,000 in mind catches most slips: going from millinewtons to nanonewtons is two steps, a factor of one million, while going from newtons is three steps. If you need piconewtons for single-molecule work, there is a separate converter for that step. Choose the unit that keeps your numbers between 1 and 1,000, and write the symbol with every value you copy into a table.
Keeping the exponent between a spreadsheet and a plot
Calibrating an instrument, correcting for tip shape, separating adhesion from load and deciding whether a force is safe for a sample depend on the instrument, the sample and the method, so a paper or standard that describes the measurement is the right place to look. Treat very small forces with care, because vibration, temperature drift and humidity can exceed the value you want to measure. When you move a number between a spreadsheet and a plotting program, check that the exponent survived the trip, since some tools round very small values to zero or drop the e notation. A one-microgram load presses with about 9.8 nN, so an axis labeled 9.8 needs its unit written beside it.
Checking a setpoint against the spring constant
A worked case shows how the unit enters a lab note. A cantilever calibrated at 0.2 N/m is deflected by 25 nm, which gives a force of 0.2 × 25 × 10^-9 N, or 5 nN. Written in newtons, the setpoint is 0.000000005 N, which is 5 × 10^-9 N. A second run at 20 nN corresponds to 2 × 10^-8 N. The product of spring constant and deflection is computed outside the page, and the converter handles the unit step. Keeping both forms in the note avoids confusion when a collaborator reads force in newtons and your software shows nN. State the calibration method next to the number, since the spring constant is usually the largest source of uncertainty.