Where nanowatt and milliwatt readings meet
Power meters for radio and optical work report in dBm, which is referenced to one milliwatt, while low-power chip data sheets list sleep and idle consumption in nanowatts. An engineer who sets up a wireless link, a technician who reads a fiber power meter and a student who writes up a lab all end up moving between the two. This page divides the nanowatt value by one million and gives milliwatts, the unit behind the dBm scale. A level of 250,000 nW, for instance, is 0.25 mW. With the milliwatt figure in hand you can take the logarithm and read the result in decibels relative to 1 mW.
2,000,000 nW as 2 mW and the reverse direction
Nano is 10^-9 and milli is 10^-3, so a milliwatt holds one million nanowatts. The page applies mW = nW × 0.000001. Milli and nano are defined prefixes, so the million is exact. By hand the decimal point moves six places to the left: 2,000,000 nW is 2 mW and 1,000 nW is 0.001 mW. To go the other way, move it six places to the right, so 20 mW is 20,000,000 nW. A fast check goes through microwatts: 1,000 nW make a microwatt, 1,000 µW make a milliwatt. Any answer larger than the input signals reversed menus. Write the factor 10^-6 beside the result in lab notes, so a reviewer can retrace the step without a calculator.
Ten nanowatts and minus fifty dBm
The default of 10 nW returns 0.00001 mW, which is 1 × 10^-5 mW. In dBm that is 10 times the base-10 logarithm of 10^-5, or -50 dBm. An optical power meter showing -50 dBm is therefore reading 10 nW. The same conversion works for other levels: 1,000 nW is 0.001 mW, which is -30 dBm, and 250,000 nW is 0.25 mW, which is about -6 dBm. Seeing the mW figure first makes the dBm step easy, and any scientific calculator does the logarithm. The page itself stops at the milliwatt and does not print decibels, so the last step is yours. For a quick estimate, remember that 1 mW is 0 dBm, 0.1 mW is -10 dBm and 0.01 mW is -20 dBm, with each further factor of ten lowering the level by another 10 dB.
Receiver levels in a Wi-Fi survey
A phone or laptop reports Wi-Fi signal strength as a negative dBm number. A level of -70 dBm is 10^-7 mW, which is 100 pW, or 0.1 nW. A stronger level of -50 dBm is 10 nW, which is the page default. Level readings in nanowatts are rarely shown by software, but converting from dBm to mW and to nW makes the scale concrete. It helps to see that each 10 dB step changes the power by a factor of ten, and that 30 dB means a factor of 1,000. When a router placed in another room drops the signal by 20 dB, the received power falls to one hundredth. The converter helps you place those values in a consistent unit.
Sleep power in a data sheet row
A sensor module may list its sleep power as 450 nW, an idle mode of 0.2 mW and a transmit burst of 15 mW. In one unit, those are 0.00045 mW, 0.2 mW and 15 mW. The huge spread is typical, and the average depends on how long the device stays in each mode. A radio that transmits 15 mW for 10 ms every minute contributes about 0.0025 mW on average, which is 2,500 nW, far more than the sleep floor. Seeing both in milliwatts lets you rank the contributions and focus on the one that matters, which is usually the burst and not the sleep.
Milliwatts back to nanowatts
When a data sheet lists a figure in milliwatts and you need it in the unit of your sleep numbers, choose milliwatts as the From unit and nanowatts as the To unit. A 5 mW laser pointer is 5,000,000 nW, and a 1 mW reference source is 1,000,000 nW. A 20 mW indicator LED circuit is 20,000,000 nW. The numbers are large and not meant to be quoted, but a table that holds an integer count of nanowatts avoids decimals when you add up many rows. Switch back to milliwatts for the presentation. Keep a column that states the unit, and avoid editing the numbers by hand.
Reading the instrument floor
Power meters have a noise floor, below which readings are not reliable. A consumer optical meter might resolve down to -50 dBm or so, which is 10 nW, and a spectrum analyzer in a radio lab reaches much lower with a narrow filter. If a reading of 12 nW sits close to the floor of your instrument, the digits after the first are suspect. Convert the reading and the floor to the same unit before you compare them, and note the filter bandwidth when radio signals are involved. The page does the unit change and leaves the judgment on what the instrument can resolve to the specification sheet and your calibration records. Meters also have a stated accuracy in decibels, which translates into a percentage error in power, so a reading of 12 nW from an instrument good to 0.5 dB could be off by about 12 percent.
Common slips with m and n
The symbols mW and nW differ by one letter and a factor of a million. A lowercase m is milli, a capital M is mega, and a lowercase n is nano. Data exported from an instrument may drop the prefix and leave only W, so confirm the unit from the instrument settings or the manual before you convert. A second slip is to confuse dBm with dB. A value in dBm is an absolute level relative to 1 mW, and a value in dB is a ratio. Writing -50 dBm is a power, and writing 50 dB is a gain or loss. Keep the unit with the number in every table so that others can follow your calculation.
What stays outside the unit change
The page restates a power value in another unit. It does not compute a link budget, antenna gain, path loss or battery life, and it does not check whether a meter reading is accurate. Radio rules on transmit power, laser classes and eye safety are set by regulators and standards, and you should read the current text that applies in your region. The converter makes sure the powers of ten match when you move between a data sheet in nanowatts and a meter in dBm or milliwatts. Note the measurement mode beside each value.