Single-molecule papers and instrument manuals

Optical and magnetic tweezers measure forces on single molecules, and the results are listed in piconewtons. Atomic force microscopes, which probe whole cells and films, report in nanonewtons. A biophysics student who reads a paper on DNA stretching and a manual for a cantilever sensor sees both units within a few pages. To compare a force range with what a sample needs, one unit is easier. This page multiplies a nanonewton value by 1,000 and returns piconewtons. It also helps when a table in a methods section spans several instruments and the rows use different prefixes for the same kind of quantity.

A factor of 1,000

Nano is 10^-9 and pico is 10^-12, so a nanonewton equals 1,000 piconewtons. The formula is pN = nN × 1000. Pico and nano appear in both the SI Brochure and NIST SP 811 with fixed values. The factor is exact. The decimal point moves three places to the right: 0.15 nN is 150 pN, and 2.5 nN is 2,500 pN. For the reverse, 65 pN is 0.065 nN. Because the result must be larger than the input when you go from nano to pico, a smaller number signals swapped units. The next smaller unit is the femtonewton, at 10^-15 N, which is 0.001 pN.

Ten nanonewtons as ten thousand piconewtons

The page opens with 10 nN and returns 10,000 pN. In single-molecule work that is a large force. Many single-molecule experiments stay below a few hundred piconewtons, so 10,000 pN is far outside their usual range. The figure shows where atomic force microscopy sits relative to tweezers: both can measure forces in the range of a few hundred piconewtons, but the instruments differ in stiffness, noise and speed. Writing the default as 10,000 pN instead of 10 nN makes the overlap and the gap clearer than the bare numbers do.

Forces on DNA and molecular motors

Published measurements report that a kinesin motor stalls at forces of a few piconewtons, and that double-stranded DNA stretched in a tweezers experiment shows an overstretching transition near 65 pN. A force of 65 pN equals 0.065 nN. These figures give a sense of the scale: the forces at work in a cell are orders of magnitude smaller than what a hand feels. If you design an experiment, the stiffness of your trap and the force range you need decide which instrument you use. This page does the unit step, and the literature and your calibration supply the numbers for your system. Reported values depend on the pulling speed, the buffer and the construct, so a number from a paper is a reference point and not a universal constant.

Weight of a nanogram

A mass of 1 ng is 10^-12 kg, and its weight at standard gravity is 9.80665 × 10^-12 N, which is 9.80665 pN, or 0.00980665 nN. So the weight of a nanogram is about 10 pN. That puts piconewtons in a familiar light: tweezers can detect forces comparable to the weight of a speck that no balance resolves. The comparison also shows why a gram-force or kilogram-force is not used in this field. The values would be tiny decimals, and the SI prefixes make them readable. One nanogram weighs about 9.8 pN.

From piconewtons to nanonewtons

To convert in the other direction, select piconewtons as the source and nanonewtons as the target. The page divides by 1,000. A force of 6 pN becomes 0.006 nN, 150 pN becomes 0.15 nN, and 9.80665 pN becomes 0.00980665 nN. If you want to express a result in one unit for a figure, choose the unit that keeps numbers between 1 and 1,000, so that a trace running from 5 pN to 800 pN is plotted in piconewtons and one from 2 nN to 40 nN in nanonewtons. Axis labels with the unit and a clear note of any conversion reduce the effort that readers spend on checking. When a figure combines data from several instruments, mark the range that each one covers, so the reader can see where one instrument ends and the next begins.

Calibration and what sets the uncertainty

Force measurements at this scale depend on a calibration of the trap or cantilever stiffness, and uncertainties of ten percent or more are common. A converted value inherits that uncertainty, and writing it with many digits is misleading. If a trap stiffness is known to about 10 percent, a force of 65 pN is better reported as 65 pN with its uncertainty than as 65.000 pN, and a value near the noise floor should carry a wider margin than one in the middle of the range. The factor of 1,000 itself is exact, so the uncertainty comes only from the measurement. A careful report states the calibration method, such as equipartition, power spectrum or drag force, and the conversion appears as a plain unit change. Reporting the trap stiffness and the sampling rate beside the force lets another group judge whether a result can be reproduced.

Units in figures and tables

In figures and tables, mixing nN and pN in one axis causes mistakes. Choose one unit for each quantity, label the axis with it, and place the converted value in the caption if both are needed. Typing pN with a capital P turns it into a different symbol, and nN versus nM is a classic typo that swaps newtons and molar concentration. Software that changes case can damage the symbols, so check files after an automatic edit. The labels on the page give the full names, and the result is shown with the unit symbol, so a copy-paste keeps the unit with the number. In a slide, put the unit on the axis and the value in the caption only once, to keep the figure uncluttered.

Force-extension plots with converted axes

Trap calibration, noise estimates and the interpretation of a force-extension curve belong to the experiment, and so do the choices of trap stiffness, loading rate and molecular model. The methods literature for your technique covers them. What the page offers is an identical result for any value, which makes it a cross-check between papers that use different prefixes. If a value looks wrong after conversion, compare the exponent with a known reference, such as 1 nN equals 1,000 pN, before looking for another cause. A plot of force against extension can also look different on a log axis, so convert the axis label along with the data.