Energy per bit, in whichever unit the paper chose

Papers and datasheets about processors, memories and links report energy per operation or per bit, and they do not agree on units. One source quotes a memory access in nanojoules while the next gives an arithmetic operation in picojoules. Putting them in one table shows the ratio that matters to an architect: moving data costs more than computing with it. This page multiplies the nanojoule value by 1,000 and returns picojoules, so the two figures can be placed side by side. It suits students, hardware engineers and anyone writing a comparison, and it removes a unit mismatch that can hide a thousandfold difference.

One step of 1,000

Nano is 10^-9 and pico is 10^-12, so a nanojoule holds 1,000 picojoules. The formula is pJ = nJ × 1000. Both prefixes are fixed by the SI, so 1,000 is exact. The decimal point moves three places to the right, so 20 nJ becomes 20,000 pJ and 0.4 nJ becomes 400 pJ. In the other direction the number gets smaller: 150 pJ is 0.15 nJ. A result must always be larger than the input when you convert from nano to pico, which is a quick test for swapped units. Next in line below the picojoule is the femtojoule, at 10^-15 J, which is 0.001 pJ.

Ten nanojoules and the number 10,000

The default of 10 nJ becomes 10,000 pJ. Reading the figure as ten thousand picojoules is a useful reminder of how many small events fit inside one larger event. A memory access costing 20 nJ (illustrative) equals 20,000 pJ. If an addition costs 20 pJ (also illustrative), the access is 1,000 times as expensive. The ratio is what a designer cares about, and it only appears after both values use one unit. Real values depend on the technology, the voltage, the memory size and the distance the data travels, so take them from the source for your design and enter them here for the unit step.

From energy per bit to power

Energy per bit times the bit rate gives power. A link that spends 150 pJ per bit and runs at 10 Gbit/s uses 150 × 10^-12 J × 10^10 s^-1, which is 1.5 W. The same 150 pJ is 0.15 nJ per bit. Which unit is natural depends on the field: optical and electrical interconnects use picojoules per bit, while wireless sensor radios use nanojoules per bit because their energy per bit is much higher. A radio that spends 50 nJ per bit spends 409,600 nJ on a 1,024-byte packet, which is 8,192 bits, or 409,600,000 pJ. The page converts the unit and leaves the rate and the packet size to you.

Reading datasheets with mixed units

It is common to see a table where one row lists a core at 12 pJ per instruction and another lists a flash write at 3 nJ per byte. To compare them, convert the flash value to picojoules: 3 nJ is 3,000 pJ. The comparison then shows that a flash byte costs 250 times as much as an instruction in this example, which are illustrative numbers. In a real comparison also check the width of the operation, since a 64-bit add and an 8-bit add do not cost the same. Use the same method when you review a vendor comparison, because a unit hidden in a table header can change the conclusion. Always read the header, not only the numbers, and note whether the figure is per byte, per bit or per operation. A per-byte value is eight times a per-bit value, and mixing them is as costly as mixing prefixes.

Going from picojoules to nanojoules

To convert in the other direction, select picojoules as the source and nanojoules as the target. The page divides by 1,000. A value of 150 pJ becomes 0.15 nJ, 2.5 pJ becomes 0.0025 nJ, and 8,000 pJ becomes 8 nJ. People do this when a circuit simulation reports picojoules per cycle and a system model needs nanojoules per operation. To keep the numbers in a comfortable range, switch to the unit in which the value lies between 1 and 1,000, and use the same unit across a whole table. A column that mixes pJ, nJ and µJ is hard to scan and invites errors.

Why a picojoule is a good unit for chips

A modern logic gate switching once uses a tiny fraction of a picojoule, and a wire carrying a signal across a chip costs more than the gate. Because designers count billions of events, picojoules and femtojoules are the practical scale. A chip that does 10^12 operations a second at 5 pJ each uses 5 W. The same figure expressed as 0.005 nJ per operation is harder to read. This explains why papers on processor efficiency choose picojoules. The conversion on this page ties those values to the nanojoule figures in system-level documents and software energy models, without any change in meaning. Cite the original unit as well, so a reader can trace the number back to the paper or datasheet it came from.

Rounding and the number of digits

The factor is exact, so the digits in the answer are your input digits shifted. Report the same number of significant figures as the least precise value in your comparison. A figure of 20 nJ has one or two digits, so 20,000 pJ should not be written as 20,000.000 pJ. When you divide one converted value by another, such as the 1,000 ratio above, round the ratio to the number of digits that your inputs support and say that the inputs are illustrative or measured. Doing so keeps a comparison honest, particularly in a report that others will read and reuse in their own calculations.

Energy per operation moves with voltage and workload

Modeling a processor, measuring power, adding leakage and accounting for the voltage and frequency of a real design are tasks for other tools. Energy per operation is a moving figure, and it changes with the workload, the temperature and the supply voltage. For design work, use measurements, vendor characterization data and the tools of your platform. For publication, cite the source of each figure. The converter helps you present figures on a single scale and gives the same result for any value you enter. A table that lists 0.25 nJ per operation in one column and 250 pJ in another invites a mismatch, so settle on one unit for the whole table before you start.