Small forces on two scales

Millinewtons describe forces that a person can feel with a finger, such as the push of a light switch or the thrust of a small spacecraft engine. Nanonewtons describe forces at the scale of microscopic probes, MEMS devices and single cells. A report on instruments that span both, or a program that stores all forces in one unit, needs the conversion. This page takes a value in millinewtons and returns nanonewtons. The default input of 10 mN returns 10,000,000 nN. The factor is a million, so each digit of the input shifts six places. The converter changes the unit of a force you already know. It does not tell you how a force arises, how a structure responds to it or whether a component is strong enough to carry it. Many data sheets print force in grams-force or millinewtons depending on the vendor, which is another reason the unit pair matters.

Deriving the factor of 10⁶

The milli prefix means 10⁻³ and the nano prefix means 10⁻⁹. A millinewton is therefore 10⁻³ N, a nanonewton is 10⁻⁹ N, and the ratio of the two is 10⁻³ divided by 10⁻⁹, which is 10⁶. The page formula is nN = mN × 1000000. Both prefixes are exact powers of ten in the SI Brochure from the BIPM, so the factor is exact. One way to count is by steps of three decimal places. Milli to micro is one step of 1,000, and micro to nano is another, so two steps give 1,000 × 1,000 = 1,000,000. The reverse direction divides by one million. The newton itself is the SI derived unit of force, equal to one kilogram meter per second squared, the force that accelerates a one kilogram mass at one meter per second squared. Because 10⁶ is a power of ten, no rounding occurs in the conversion itself. Any rounding in the displayed result comes from the number of digits shown.

The default of 10 mN

The default entry is 10 mN. Multiplying by 1,000,000 gives 10,000,000 nN, written 1 × 10⁷ nN. A check through newtons: 10 mN is 0.01 N, and dividing by 10⁻⁹ N per nanonewton gives 10⁷. If the result shows 10,000 or 10,000,000,000, the wrong prefix step was used, for instance micro instead of nano. The number has eight digits, one followed by seven zeros, because the input contributes one extra zero to the six that the factor supplies. To visualize the default, 10 mN is roughly the weight of a 1-gram object, since 1 gram of mass weighs 9.80665 mN under standard gravity. So the default is about the weight of a paper clip. That is a useful anchor for what millinewton values mean physically.

Weight, grams and gram-force

The weight of a mass depends on gravity. Under standard gravity of 9.80665 m/s², a mass of 1 gram weighs 0.00980665 N, which is 9.80665 mN or 9,806,650 nN. This is the gram-force, an older unit that is exactly 9.80665 mN. A 100-gram apple weighs about 0.98 N, since 0.1 kg times 9.80665 is 0.980665 N. The CGS unit of force is the dyne, equal to 10⁻⁵ N, which is 0.01 mN or 10,000 nN. These relationships let you connect a balance reading in grams to a force in millinewtons. Remember that a balance measures mass by comparing weights, and a conversion to force assumes standard gravity. At other locations the local gravitational acceleration differs by up to about half a percent from the standard value. A kilogram-force is 9.80665 N, so a gram-force is a thousandth of that, and a table in grams-force can be turned into millinewtons by multiplying by 9.80665.

Millinewtons in spaceflight and instruments

Electric propulsion systems produce forces measured in millinewtons. An ion thruster of the kind flown on deep-space probes typically provides a thrust in the range of tens of millinewtons, and the NSTAR thruster on the Deep Space 1 mission had a maximum thrust of about 92 mN. That is the weight of an object of about nine grams, but applied for months it changes the velocity of a spacecraft by kilometers per second. Small cold-gas thrusters on CubeSats operate at similar or lower thrust levels. Force sensors for testing such thrusters measure down to the micronewton range. Expressing 92 mN as 92,000,000 nN shows how many sensitive steps lie between the thruster and the resolution limit of the best force sensors. The values are given as illustrations, not as a guide to any particular thruster. At 92 mN, a spacecraft of 500 kg would accelerate at about 0.000184 m/s², which is roughly 16 m/s gained per day. The spacecraft mass is an illustrative assumption.

Nanonewtons in microscopy

The atomic force microscope senses forces between a sharp tip and a surface, and the forces involved range from piconewtons to hundreds of nanonewtons. The probe is a tiny cantilever that behaves like a spring, so its deflection x and spring constant k give a force F = kx. A cantilever with k = 0.1 N/m deflected by 10 nm exerts 1 nN, since 0.1 × 10⁻⁸ is 10⁻⁹ N. Biologists use similar probes to push on cells and measure stiffness, with forces of tens to hundreds of nanonewtons. MEMS devices such as accelerometer proof masses and microgrippers operate at the nanonewton to micronewton level. At these scales, 1 mN is enormous: it is a million times a 1 nN tip force, which explains why the unit pair spans such different instruments. Optical tweezers work at an even lower scale of piconewtons, a thousand times smaller than nanonewtons, so a 5 pN trap force is 0.005 nN.

Worked examples

For 50 mN, the result is 50,000,000 nN, or 5 × 10⁷ nN. For 9.80665 mN, the weight of one gram, the result is 9,806,650 nN. For the reverse direction, 3 nN is 0.000003 mN, found by swapping the units and entering 3. A round trip should return the original value. These conversions follow one rule: moving from the larger unit to the smaller multiplies by one million. An easy way to avoid a slip is to write the units in a chain, 10 mN = 0.01 N = 10,000,000 nN, so that each step moves by a clear power of ten. In a spreadsheet, keep the factor in a labeled cell with the value 1E+6 and use it in every row. The examples use illustrative values chosen to be easy to check by hand.

How small forces are measured

Forces at the millinewton level can be measured with load cells, strain gauge bridges and precision balances. Below that, instruments use torsion pendulums, electrostatic force balances, cantilever probes with optical or electrical readout, and magnetic levitation setups. The resolution of a sensor is the smallest change in force it can distinguish, and the range is the largest force it can measure. A sensor with a range of 100 mN and a resolution of 1 µN has a dynamic range of 100,000, or 100 dB. Calibration against a known weight or an electrostatic force standard is necessary to achieve the stated accuracy. When you convert a measured value, keep its stated uncertainty and convert that as well, because 2 mN ± 0.1 mN is 2,000,000 nN ± 100,000 nN. A conversion does not add or remove uncertainty. Environmental vibration, air currents and thermal drift often limit measurements of small forces more than the sensor does, so careful setups use isolation and enclosures.

Force versus torque and surface tension

Be careful that a value in millinewtons is a force. Torque is measured in newton meters, so a value in mN·m is a torque, not a force, and cannot be converted to nanonewtons without a lever arm. Surface tension is a force per length, usually quoted in mN/m. Water at room temperature has a surface tension of about 72 mN/m, which is 0.072 N/m. It is not 72 mN. A force per length cannot be treated as a force without multiplying by a length. A similar caution applies to pressure, which is force per area. The converter takes a plain force. If your source value has a slash or a dot with another unit, it is probably a different quantity, and you need another conversion tool for it.

Notation and typing

The symbol for newton is a capital N, and prefixes use lowercase for milli and nano: mN and nN. A capital M would mean mega, so MN is a meganewton, a force of a million newtons used in structural engineering and for rocket engine thrust. The difference between mN and MN is a factor of 10⁹. Confusing them is a risk when text is typed fast or case is lost in a spreadsheet. For nanonewton, some writers use nn, which is not correct. In a table, spell out the unit in the heading, and show the exponent clearly. When working in engineering notation, use powers of ten that are multiples of three, which match the SI prefixes: 10⁻³ for milli, 10⁻⁶ for micro and 10⁻⁹ for nano. That convention helps avoid mistakes when converting between them.

Limits of the converter

The page changes the unit of a force value. It does not calculate structural capacity, thrust requirements, material response or safety, and it does not decide whether a sensor is suitable for a measurement. For definitions, see the BIPM SI Brochure and NIST Special Publication 811. Keep the original unit with every converted value so that other people can follow the arithmetic. The factor is exact, so any difference between this page and another tool usually comes from a different unit selection or a typing slip in the input.