Pulse energy and particle energy

A pulsed laser or a particle beam is described by two kinds of energy. The total in a pulse is a macroscopic number, often in millijoules. The energy of each photon or particle is tiny and given in electronvolts. To count how many photons a pulse contains, or to see what a total means per particle, both numbers must be in one unit. This page multiplies the millijoule value by about 6.24151 × 10^15 and returns electronvolts. The result is very large because the electronvolt is a very small unit of energy, so use exponent notation for readability. Readers who need this include students working through photon-counting problems, technicians who read a pulse energy off a laser power meter and want to relate it to the photon energy printed on the laser label, and researchers comparing a beam total with the threshold energy of a material or detector listed in electronvolts.

Exact elementary charge and the eV factor

Since the 2019 revision of the SI, the elementary charge is fixed at 1.602176634 × 10^-19 coulomb, and the electronvolt, accepted for use with the SI, equals that many joules: 1 eV = 1.602176634 × 10^-19 J exactly. A millijoule is 10^-3 J, so one millijoule is 1 / (1.602176634 × 10^-22) eV, about 6.241509 × 10^15 eV. The BIPM SI Brochure lists the electronvolt among the non-SI units accepted for use. Because the definition is exact, the only limit on accuracy is the number you enter. Before 2019 the electronvolt was tied to a measured value of the elementary charge, so older tables list the factor with a small uncertainty and slightly different trailing digits. Current references, including the SI Brochure, use the fixed value, and the page follows it, so a handbook printed before the redefinition may differ in the eighth digit or later.

Ten millijoules in electronvolts

With 10 mJ entered, the result is about 6.2415 × 10^16 eV, a sixteen-digit number plus one. The size of the result is its own check. A millijoule is around 6 × 10^15 eV, so ten times that is about 6 × 10^16. If the page shows 10^13 or 10^19, a unit was selected wrongly. For comparison, 1 mJ is 6,241,509,074,460,763 eV by the factor. Reading numbers this long is difficult, so copy them in exponent form into reports and spreadsheets. A spreadsheet that stores the value as text, or as a number with a limited digit count, may round a 17-digit integer, so keep the exponent form and the original millijoule value in neighboring cells. That way anyone who doubts the long figure can recompute it from the short one in a few seconds.

Counting photons in a laser pulse

A photon of wavelength 532 nm, the common green line of frequency-doubled lasers, carries about 1,239.84 / 532 = 2.33 eV. A pulse of 1 mJ is 6.2415 × 10^15 eV, so it contains about 2.68 × 10^15 such photons. A 10 mJ pulse contains ten times as many, roughly 2.68 × 10^16. The wavelength-to-energy relation, E in eV equal to 1,239.84 divided by the wavelength in nanometers, is a handy approximation. The calculation assumes all the pulse energy is in photons of that one wavelength, which real pulses only approximate. A 1064 nm infrared line has a photon energy of about 1,239.84 / 1,064 = 1.165 eV, so the same 1 mJ pulse holds about 5.36 × 10^15 photons, roughly twice as many as at 532 nm. Longer wavelengths mean smaller photons and therefore more photons for the same pulse energy, a relation that matters when you compare detectors or damage thresholds between lines.

Converting electronvolts to millijoules

To go the other way, select electronvolts as the source and millijoules as the target. A 1 TeV particle, which is 10^12 eV, carries 1.602 × 10^-7 J, which is 1.602 × 10^-4 mJ. A 100 keV electron has 1.602 × 10^-11 mJ. The result is a tiny decimal, so use exponent form. Compare these with the pulse energy, and you see why detectors count many particles to produce a measurable signal: a single particle carries almost nothing compared with a millijoule. A dental or medical X-ray tube operated at 70 kV accelerates electrons to at most 70 keV, which is 1.12 × 10^-14 J, or 1.12 × 10^-11 mJ. It takes about 8.9 × 10^10 such electrons to carry one millijoule, a count that is easy to reach because tube currents move millions of billions of electrons per second.

Semiconductors and detectors

Band gaps and detector thresholds are given in electronvolts. Silicon has a band gap of about 1.12 eV, which is 1.794 × 10^-19 J. A solar cell or a photodiode responds to photons above that energy, and a datasheet may give light power in watts or pulse energy in millijoules. Converting one to the other tells you how many photons arrive. These are approximate ideas, since real devices have quantum efficiency, reflection and temperature effects that the page does not model. The conversion only provides the energy link between the two units.

Mixing up eV, keV and MeV

Particle physics tables mix eV, keV, MeV, GeV and TeV, and each step is a factor of 1,000. A result of 6.24 × 10^15 eV can be written as 6.24 × 10^12 MeV or 6.24 × 10^9 GeV. The page returns plain electronvolts, so convert further if your source uses a bigger unit. A slip of one prefix changes the answer by 1,000 and is easy to make at this scale. Write the unit with every number and prefer exponent notation to avoid counting zeros.

Precision and rounding

Because the electronvolt is defined exactly, the factor adds no uncertainty. Pulse energy meters usually have uncertainties of several percent, so quote two or three significant digits. For the default, 6.24 × 10^16 eV is plenty. The page rounds only the displayed output and keeps full precision internally, so a chain of conversions does not drift. Keep the original millijoule value and the detector settings in your notes.

What this page does not calculate

The converter changes the unit of an energy value. It does not compute photon number for a spectrum, laser safety, beam damage thresholds or detector response. Safety classification of lasers and exposure limits come from standards and the manufacturer, and they depend on wavelength, pulse length and beam size. Use the page to relate two units and consult the proper standards for any decision about use or safety.