Sleep modes quoted in two units
Microcontroller and sensor datasheets list their lowest-power states in microwatts, and the very best parts state them in nanowatts. A designer comparing a chip that sleeps at 1.5 µW with one that quotes 900 nW has to bring them to one unit before choosing. This page multiplies microwatts by 1,000 to give nanowatts, and divides by 1,000 for the reverse direction. The ratio is fixed by the SI prefixes. The converter gives the unit change and nothing about the part itself, so it does not tell you which chip is better for a design, whether a low sleep figure survives at high temperature, or how the part behaves when it wakes.
Micro and nano in the SI system
The SI Brochure of the BIPM lists micro as 10^-6 and nano as 10^-9. A nanowatt is therefore 10^-9 W, and one microwatt holds 1,000 of them. The formula on this page is nW = µW × 1,000, and the default of 10 µW gives 10,000 nW. The page may display 9999.999999999998 because of binary floating-point arithmetic, which should be read as 10,000. Because the factor is a pure power of ten, digits carry over unchanged. A value of 1.5 µW becomes 1,500 nW, 0.35 µW becomes 350 nW, and 0.002 µW becomes 2 nW, which shows why nanowatts are the more convenient unit for the lowest sleep figures. The same ladder continues downward, since 1 nW is 1,000 pW, so a value quoted in picowatts can be brought back to microwatts by dividing by one million.
From a real-time clock current to nanowatts
A real-time clock chip keeps time from a backup cell and may list a timekeeping current of 500 nA at 3 V. Power is voltage times current, so that is 1,500 nW, or 1.5 µW. A second chip drawing 0.8 µA at 3 V uses 2.4 µW, which is 2,400 nW. The data sheet of each part states current, and you supply the voltage of your own supply. Converting both to nanowatts lets you see that the second chip draws 60 percent more. The page performs only the µW to nW step, so work out voltage times current yourself first, then enter the result in microwatts and read the nanowatt equivalent.
How long a coin cell lasts
A typical CR2032 coin cell is rated around 225 mAh at 3 V, which is about 675 mWh of stored energy. A circuit averaging 15 µW, or 15,000 nW, would drain that in 45,000 hours, a little over five years, if the cell delivered its full rating. In practice, self-discharge, temperature and pulse loads reduce the usable capacity, so treat the result as an upper bound. An average of 1,500 nW stretches the same arithmetic ten times, to 450,000 hours, far longer than the shelf life of the cell. That is why quoted battery life for ultra-low-power devices is limited by the cell chemistry and not by the circuit.
Averages hide the wake-up bursts
A device that sleeps at 900 nW and wakes once a minute to transmit does not average 900 nW. A burst of 30 mW lasting 5 milliseconds each minute adds 30,000 µW × 0.005 s = 150 µJ per cycle, which spread over 60 seconds is 2.5 µW, or 2,500 nW. The average is then about 3.4 µW, well above the sleep value. Converting each contribution to the same unit and adding them is the right method. The burst figures here are illustrative. Use your own part data for the wake current and duration, and expect the bursts to dominate the budget for most sensing duty cycles. Halving the wake interval from 60 seconds to 30 doubles the burst contribution to 5 µW, or 5,000 nW, so the interval is often a bigger lever than the sleep figure on the datasheet. Entering each term in microwatts, adding them, and converting the total once keeps the arithmetic traceable.
Reading nanowatts on a bench
Measuring microwatt-level loads is hard because ordinary multimeters have burden voltage and offset errors that are comparable to the signal. A source-measure unit or a purpose-built current profiler gives better results, and some read directly in nanoamps. A reading of 330 nA at 3 V is 990 nW, close to 1 µW. If you take readings at several supply voltages, record the voltage with each current so that the power can be recomputed. The converter helps with the last step, when a table of results in µW has to be shown in nW to line up with a datasheet that uses that unit.
Choosing the unit for a table
Pick the unit that keeps most values between 1 and 999. A list of sleep powers such as 0.9, 1.5, 2.4 and 3.2 µW looks better as 900, 1,500, 2,400 and 3,200 nW, because the whole numbers are easier to compare at a glance. A list that includes values in the tens of microwatts reads better in µW. Do not mix units in one column. If you must, label each cell. Exports from spreadsheets sometimes drop the unit, so keep a note of it in the column header, and use the symbols µW and nW with a micro sign and a lowercase n.
Typical mistakes
The most common error is moving the decimal in the wrong direction. A bigger unit gives a smaller number, so nanowatts are a smaller unit than microwatts and give a larger number: 4 µW is 4,000 nW, not 0.004 nW. A second error is confusing nW with mW, which differ by a factor of one million, so a sleep figure of 900 nW is 0.0009 mW and not 0.9 mW. A third is forgetting that power in a circuit depends on supply voltage, so a datasheet figure at 1.8 V does not hold at 3.3 V. This page cannot catch those, and it only performs the arithmetic you request.
Boundaries of the page
The page converts a power value from microwatts to nanowatts. It does not estimate battery life beyond the examples, judge component choice, or provide any electrical safety or compliance assessment. The prefix definitions come from the BIPM SI Brochure and from NIST SP 811, listed as sources for this page. Displayed values are rounded, and some outputs carry a floating-point tail in the last digits. When a figure feeds a design decision, use the manufacturer data at the stated temperature and supply voltage and keep the original value with its unit.