Joining two ends of the field-strength scale
Electric fields in practice run from microvolts per meter, where a distant broadcast signal sits at an antenna, to many kilovolts per centimeter inside a gap or a cuvette. People in different fields use different units, kilovolts per centimeter in high-voltage and biology benches, millivolts per meter in radio engineering and field strength surveys. This page converts from the first to the second. It is mostly a comparison tool: it expresses a strong, short-gap stress in the unit that radio and electromagnetic compatibility documents use, so that numbers of wildly different size can be set side by side. Both prefix and length change in one conversion, which is where mistakes tend to occur.
Building the factor of 10^8
There are two steps. First, kilovolts to millivolts: 1 kV is 1,000 V, and each volt is 1,000 mV, so 1 kV is 1,000,000 mV. Second, per centimeter to per meter: a meter is 100 cm, so the per-meter value is 100 times the per-centimeter value. Together, 1 kV/cm = 1,000,000 × 100 = 100,000,000 mV/m, or 10^8 mV/m. The page formula is mV/m = kV/cm × 100,000,000. The prefixes follow the SI tables in BIPM documents and NIST SP 811, and the factor is exact. If you prefer two stages, convert to V/m first (multiply by 100,000) and then multiply by 1,000 to reach mV/m.
The default result of 10 kV/cm
Ten kV/cm returns 1,000,000,000 mV/m, which is 1 × 10^9 mV/m. In volts per meter that is 1,000,000 V/m, or 1 MV/m. A value that large in millivolts per meter is never quoted in practice, and that is the point of the example: it shows how far apart the working ranges of the two units are. The strong end of a high-voltage experiment and the weak end of a radio survey differ by many orders of magnitude, and the converter makes the size of that difference concrete. When a ratio is the goal, converting both numbers to millivolts per meter and dividing is the cleanest route.
Radio field strength for comparison
Broadcast coverage maps and receiver specifications use field strength in millivolts or microvolts per meter, often in decibels relative to one microvolt per meter. A level of 1 mV/m corresponds to 60 dBµV/m. A signal of 5 mV/m is a good reception level in many planning documents. Compare that with 0.001 kV/cm, a modest bench field of 1 V/cm. Entering 0.001 here returns 100,000 mV/m, which is 20,000 times the 5 mV/m reception level. The comparison is only about size of the field, since the two situations involve different frequencies and purposes, but it shows why radio documents do not use kilovolt-based units.
Test-gap example with a small value
A test engineer applies 3 kV across a 1 cm electrode gap and records 3 kV/cm. The page converts that to 300,000,000 mV/m. If the same engineer reads an immunity standard that specifies a test field of 10 V/m for radiated electromagnetic compatibility testing, the standard's level is 10,000 mV/m. The gap stress is therefore 30,000 times larger than that test field. The two are unrelated phenomena, a static or slowly varying stress across an insulating gap and a radiated field applied to a device, but common units make the scale comparison immediate. The converter gives the first number, and the second is a one-step multiplication.
When the other direction is easier
If you start with a small field in millivolts per meter and want it in kilovolts per centimeter, select millivolts per meter as the source. A field of 2 mV/m comes out as 0.00000002 kV/cm. Numbers that small show that the two units are poorly matched for the same quantity, which is a hint to stop and choose a unit nearer the working range, for example microvolts per meter for the weak signal. A good habit is to report a field in the unit that gives a number between 0.1 and 1,000 for the situation at hand and to convert only when comparing across documents.
Common errors in this conversion
The factor has eight zeros, so a dropped digit changes the result by ten times. The usual slips are using 10^6 instead of 10^8, forgetting the length change, or applying the length change in the wrong direction. A rough check helps: kV/cm to V/m multiplies by 10^5, and V/m to mV/m multiplies by 10^3, so 1 kV/cm must be about 10^8 mV/m. If your answer has fewer digits than the input, the direction is wrong. Keep the unit symbols attached to every number in your working, since mV/m and kV/m differ by 10^6 and look similar when written quickly.
What this conversion does not provide
The page changes the units of a field value. It does not assess exposure, interference or breakdown, and it does not state compliance with a radio, safety or product standard. Field strength in a real situation depends on geometry, frequency and the instrument used, and a nominal voltage divided by a gap length is an average that ignores edge effects. For a limit or a test level, use the value and unit given by the governing standard. The converted number is exact for the prefixes involved, and any uncertainty comes from the original measurement. Instruments also differ in what they report. A field probe for radio work returns a field in volts or millivolts per meter, usually as an RMS value over a bandwidth, while a high-voltage test set reports a voltage that you divide by a gap yourself. Make sure both numbers describe the same kind of quantity, such as RMS or peak, before you compare them after conversion, or the factor of about 1.41 between peak and RMS of a sine wave will sit hidden inside your result.
Pulsed electric field treatment of food
Pulsed electric field processing of juices and plant tissue is one more place where kV/cm figures appear in the literature. Permeabilizing plant cells, for example in potato tissue, is usually described with fields of a few kV/cm, while inactivating microorganisms in liquids is usually reported at tens of kV/cm. A field of 30 kV/cm in that second range converts to 3,000,000,000 mV/m, and a 1.5 kV/cm treatment converts to 150,000,000 mV/m. These are published ranges that vary with pulse shape, number of pulses and product, so treat them as orientation figures rather than recipes. The point of converting is only to place a processing field next to an electromagnetic compatibility or radio level in a common unit.