Sound pressure rides on atmospheric pressure

A sound wave is a tiny fluctuation on top of atmospheric pressure. Air pressure at sea level is 101.325 kPa, while the quietest sound a young listener can detect is a fluctuation of about 20 µPa. Acoustics therefore works in micropascals, and meteorology and barometers work in kilopascals. The two meet in a report that gives both the ambient pressure and the sound pressure. This page turns the kPa value into µPa by multiplying by one billion, and the comparison shows how small a sound wave is relative to the pressure it rides on, a ratio of about five thousand million to one.

The factor and the opening example

Kilo is 10 to the third and micro is 10 to the minus sixth, so one kPa is 1,000,000,000 µPa. The default of 10 kPa becomes 10,000,000,000 µPa. One standard atmosphere, 101.325 kPa, is 101,325,000,000 µPa. A pressure of 1 Pa, which is 0.001 kPa, is 1,000,000 µPa. In the reverse direction, 20 µPa is 0.00000002 kPa. The digit count is a quick check: each kPa multiplies the value by nine zeros, so a one-digit kPa input gives a ten-digit µPa result.

The 20 µPa reference and decibels

Sound pressure level in air is defined relative to 20 µPa, the reference pressure. A level of 0 dB corresponds to 20 µPa, and every increase of 20 dB multiplies the pressure by ten. So 20 dB is 200 µPa, 40 dB is 2,000 µPa, and 94 dB is about 1,000,000 µPa, or 1 Pa. Microphone calibrators commonly generate 94 dB at 1 kHz, which is 1 Pa, or 0.001 kPa. A level of 100 dB is 2 Pa, which is 0.002 kPa or 2,000,000 µPa. A level of 85 dB is about 0.356 Pa. The decibel scale compresses these numbers, and the converter helps when a data sheet gives pressure and a meter gives decibels. A ratio of 3.16 in pressure is 10 dB, and a doubling of pressure is about 6 dB, so 40 µPa corresponds to about 6 dB.

Calibrating a sound level meter

A technician checks a sound level meter by placing a calibrator over the microphone and adjusting the meter to read the calibrator level. A 94 dB calibrator produces 1 Pa, which is 1,000,000 µPa, and a 114 dB calibrator produces about 10 Pa, which is 10,000,000 µPa. If the calibrator certificate lists a pressure in kPa, such as 0.001 kPa, converting to µPa lets you place it beside the reference of 20 µPa, and the ratio of 50,000 gives 94 dB, since 20 times log10 of 50,000 is about 94. The calibrator itself is traceable to a standards laboratory, and its certificate states the uncertainty.

Underwater acoustics use 1 µPa

Underwater sound pressure is referenced to 1 µPa instead of 20 µPa. A pressure of 1 Pa, which is 1,000,000 µPa, corresponds to 120 dB relative to 1 µPa, while in air it is 94 dB relative to 20 µPa. The 26 dB gap comes from the ratio of the two references, 20, since 20 times log10 of 20 is about 26. A hydrophone data sheet may give sensitivity in volts per µPa. Reading reports from both fields requires keeping the reference attached to each decibel figure, and converting pressures to µPa first makes comparison simple.

Microphone sensitivity and units

Measurement microphones are specified in millivolts per pascal, and a sensitivity of 50 mV/Pa at 1 Pa gives 50 mV. At 1,000,000 µPa input, which is 1 Pa, that is the same figure. The pressure sensor in a data logger might record values in kPa and the microphone channel in Pa, and a post-processing script has to convert one to the other. When a plot labels a pressure axis in µPa and another in kPa, convert before overlaying. The converter gives the numbers, and the calibration of each sensor decides how much to trust them.

Absolute versus fluctuating pressure

Acoustic pressure in these units is the fluctuation around the mean, usually an RMS value, and not the absolute pressure. A sound level of 94 dB does not mean the total pressure is 1 Pa. It means the pressure varies by 1 Pa RMS around about 101,325 Pa. In a spreadsheet, keep a column for each quantity and never add them. The converter treats any number as a pressure and cannot know which kind you mean, so label the meaning of each column. Peak and RMS values differ by a factor of about 1.414 for a sine wave, which is another detail to record. A peak of 1.414 Pa is the same wave as 1 Pa RMS, and the first is 1,414,000 µPa while the second is 1,000,000 µPa, so state which kind of value a table holds.

Acoustic pressure is not a noise limit

The page converts a pressure from one unit to another. It does not calculate sound level from pressure, apply frequency weighting, or judge exposure to noise. Noise limits come from regulations and standards, and measurements require calibrated equipment and trained users. Use the page to line up numbers in a common unit, then follow the relevant standard for any assessment.

Everyday sound levels in micropascals

Placing familiar levels on the pressure scale shows how wide the range is. A quiet room near 30 dB is about 632 µPa. Conversation near 60 dB is 20,000 µPa, which is 0.00002 kPa. A level of 70 dB is about 63,246 µPa, and 110 dB is about 6,324,555 µPa, or 6.3 Pa. Each step of 20 dB is a factor of ten in pressure, so the loudest of these has a pressure about 10,000 times that of the conversation, even though the level number only rose by 50. The dB values are round illustrative levels, and real environments vary. A sound level meter reads decibels directly, so the pressures here serve as a way to relate a meter to a transducer data sheet in pascals. The decibel relation is level equals 20 times the base-10 logarithm of the pressure divided by 20 µPa. A pressure of 2,000,000 µPa divided by 20 µPa is 100,000, whose logarithm is 5, giving 100 dB. If you have a pressure in kPa and want a level, convert to µPa first, divide by 20, take the logarithm and multiply by 20, and keep the conversion in its own spreadsheet cell so each step stays visible for review.