Filter and driver design in ω, parts in kHz

Audio crossovers, ultrasonic transducers and switching power supplies sit in the kilohertz range, from a few kHz up to a few hundred. Their design equations are written with the angular frequency ω in radians per second, because impedance terms such as ωL and 1/(ωC) read cleanly that way. Catalogs, simulators and test equipment use kilohertz. An engineer who calculates ω and then has to pick a part, set a function generator or read a spectrum needs the other unit at once. This page converts rad/s to kHz in one multiplication, so the design value and the bench value can be written side by side in the same note.

The factor behind the page

A cycle spans 2π radians, so f = ω/(2π) in hertz, and dividing by 1,000 gives kilohertz: kHz = rad/s × 0.000159154943092. The hertz, the kilohertz and the radian all come from the SI Brochure, and the factor contains no measured quantity. By hand, divide by 6,283.19. A value of 6,283.19 rad/s equals 1 kHz, a good reference to remember. Roughly, 6,000 rad/s is a little under 1 kHz, and 60,000 rad/s is a little under 10 kHz. If your answer is more than the input, the conversion went the wrong way, because a kilohertz is a much larger unit than a radian per second.

Why 10 rad/s looks tiny in kilohertz

The default of 10 rad/s returns 0.0015915 kHz, which is 1.5915 Hz. The figure is correct and looks tiny because the oscillation is far below the kilohertz range. It is the speed of a slow mechanical motion and not of anything electrical or acoustic. The engine prints extra digits at the end of the decimal, and those are an artifact of binary arithmetic. If you are working in the audio range, expect inputs in the thousands of rad/s: 1,000 rad/s gives 0.159 kHz, 10,000 rad/s gives 1.59 kHz, and 100,000 rad/s gives 15.9 kHz. Such a spacing helps to confirm that a value belongs in the kHz range.

An RC filter corner from component values

A first-order RC low-pass filter has a corner at ω = 1/(RC). With R = 10 kΩ and C = 100 nF, the product is 0.001 s, so ω = 1,000 rad/s. The page converts that to 0.15915 kHz, which is 159.15 Hz. A designer who wants a corner near 1 kHz would need ω ≈ 6,283 rad/s, so RC must fall to 0.159 ms. The example is illustrative, and it shows why the conversion belongs in the design loop. The calculator does not choose components or check tolerance, and real capacitors vary by several percent, so the corner of a built filter can sit measurably away from the calculated one. Choose parts with 1 percent resistors and 5 percent or better capacitors if the corner has to land close, and measure the result on the bench.

Switching supplies at 100 kHz

Many switching regulators run at fixed frequencies from tens of kilohertz to several hundred. A converter that switches at 100 kHz has ω = 628,318.5 rad/s. That is the number used in the formulas for output ripple and for the corner of the LC output filter, while the controller datasheet prints the frequency in kHz. A power electronics engineer who builds a model in rad/s and a layout in kHz has to translate every time, and one wrong conversion shifts a filter corner by a factor of 6.28. Enter 628,318.5 with kilohertz as the target and the page returns 100, which confirms that the model and the part agree.

Ultrasonic cleaners and audio limits

Ultrasonic cleaners for jewelry, lenses and lab glassware typically run at 40 kHz, an angular frequency of 251,327 rad/s. The upper edge of human hearing is conventionally taken as 20 kHz, which is 125,664 rad/s, and the lower edge near 20 Hz is 125.7 rad/s. These everyday reference points tell you at a glance whether a number in rad/s lies in the audible band or above it. A transducer driven at 251,327 rad/s is silent to most people, though the cleaning tank can still produce an audible hiss from the process. The page converts the number and does not judge what a given frequency does to a part in the tank.

From kilohertz back to rad/s

Select kilohertz as the source and radians per second as the target to go the other way. A 1 kHz test tone has ω = 6,283.19 rad/s, and a 20 kHz limit has ω = 125,663.7 rad/s. This direction serves someone who reads the frequency off a data sheet and has to enter ω in a simulation or in a formula, for example to compute the reactance of a capacitor. Multiply by 2π × 1,000 and keep four or five significant digits. Because the numbers run to six digits, it helps to enter them in scientific notation and to compare the exponent with a mental estimate of 6.28 times the kilohertz value times a thousand.

Keeping hertz and rad/s apart in a spreadsheet

A table of component values and frequencies often mixes the two units without warning, and the factor of 6.28 is easy to miss because both columns hold plausible numbers. Put the unit in every column header, give ω its own column, and compute f from it with a formula and not by hand. If a colleague passes you a list of corner frequencies with no unit, test one against a known case: a filter built from 10 kΩ and 100 nF has a corner of 159 Hz or 1,000 rad/s, and only one of those numbers will match. The same habit prevents errors in firmware, where a constant might be defined as ω in one file and f in another.

Calculated corner versus built circuit

A frequency typed into this page carries no memory of its circuit. It does not know whether a design is a low-pass or a high-pass filter, whether the source is a sine wave, or how a transducer responds near its resonance, and it does not model tolerance in parts. A converted figure of 159.15 Hz says where a corner is calculated to be, not where a built circuit will place it. For a product, measure the real frequency response with a signal generator and an oscilloscope or an analyzer, and use the conversion to check that the measurement and the design are expressed in the same unit before comparing them.