The two most common household flow units
Liters per minute is how most people picture water. A shower head, a bath tap, a dishwasher inlet and a garden hose are all easy to judge by the number of liters that arrive in a minute. Liters per second is how larger systems are rated: pump curves, pipe schedules, hydrant tests and treatment plant capacities in many countries use it. The same flow therefore appears on two scales, and moving between them is a regular task for plumbers, irrigation designers, facility managers and students of fluid mechanics. This converter takes a value in liters per minute and returns the equivalent in liters per second. It changes only the time unit and does not alter the volume, so the result describes the same physical flow, just counted per second rather than per minute.
Dividing by 60
Because a minute holds 60 seconds, the number of liters per second is the liters per minute divided by 60. The page gives this as a multiplication by 0.0166666666667. The default entry of 10 L/min gives 0.1667 L/s. Round examples are easier to remember. A flow of 60 L/min is exactly 1 L/s, 90 L/min is 1.5 L/s, and 15 L/min is 0.25 L/s. Going the other way, 2 L/s is 120 L/min, and 0.5 L/s is 30 L/min. The factor follows from the definition of the minute as exactly 60 seconds, so no rounding error enters from the physics. Only the display of the repeating decimal 0.0166666 is rounded. NIST SP 811 lists the minute among the non-SI units accepted for use with the SI, which is why this ratio is exact.
A garden hose and a sprinkler
Consider a garden hose that fills a 10-liter bucket in 40 seconds. The flow is 10 divided by 40, or 0.25 L/s, which is 15 L/min. A sprinkler head rated at 6 L/min uses 0.1 L/s, so that hose can feed two of them with 3 L/min to spare. When planning a small irrigation zone, the designer adds up the flows of all the outlets that run at once and checks the total against what the supply can deliver. Doing that sum in liters per second is easier when the supply is described that way, for instance a pump rated at 0.8 L/s. Converting each sprinkler from L/min first, using this tool, avoids having to carry fractions of 60 through the sum, and it makes the final comparison a matter of reading one total against one rating.
Pump and borehole ratings
Pump data sheets in many regions list flow in liters per second, while the small submersible pump you buy for a rain tank may be labeled in liters per minute. A rainwater pump advertised at 45 L/min delivers 0.75 L/s. A borehole yield test might report 1.2 L/s, which is 72 L/min, or 4,320 L/h. Yield matters because a borehole that supplies 1.2 L/s cannot sustain a pump that draws 2 L/s for long, no matter how large the tank is. The practical use of the conversion is to put the pump and the source in the same unit before judging whether they match. If you work in cubic meters per hour, multiply liters per second by 3.6, so that 0.75 L/s is 2.7 m³/h. Each of these steps is a simple ratio, and the converter lists the units so you can reach them directly.
Comparing with US gallons per minute
Pumps and fixtures sold in the United States are rated in gallons per minute. One US gallon is exactly 3.785411784 liters, so 1 gal/min is 3.7854 L/min, which is 0.0631 L/s. A fixture rated at 2.5 gal/min uses about 9.46 L/min, or 0.158 L/s. A 20 gal/min pump delivers 75.7 L/min, or 1.26 L/s. For a quick estimate, remember that 1 L/s is about 15.85 US gal/min. The converter includes US and UK gallons per minute in its unit menus, so you can run those comparisons without a separate tool. As always with gallons, confirm which one a manufacturer means, since the imperial gallon is 4.54609 liters and the same number in imp gal/min describes about 20 percent more water than in US gal/min.
Pumping out a flooded basement
A sump or submersible utility pump is often sold with a flow in liters per minute, while the question you actually have is how long the water will take to go. Suppose a basement floor measures 4 m by 5 m and holds water 10 cm deep. That is 2 cubic meters, or 2,000 liters. A pump delivering 80 L/min removes it in 25 minutes, and the same pump is 1.33 L/s, which is the figure to use if you are timing it against a stopwatch that counts seconds. The label is a free-discharge value, so a long hose or a lift up to a window slows the pump, and a rating of 80 L/min may mean 50 or 60 at a real head. As the level falls the pump may also begin to suck air near the bottom, which stretches the last few centimeters. The room size and depth here are illustrative.
Cooling water and heat carried away
A cooling circuit carries heat in proportion to its flow, and water is the usual carrier: a liter has a mass close to 1 kg and warms by one kelvin for each 4.18 kJ absorbed. A flow of 60 L/min is 1 L/s, and if the water warms by 10 K as it passes through a heat exchanger it carries away about 41.8 kW. At 30 L/min, or 0.5 L/s, the same temperature rise carries 20.9 kW, so halving the flow halves the heat removed unless the temperature rise grows. The figures are illustrative and ignore losses, but they show why cooling specifications give flow and temperature together. A value read in L/min on one gauge and L/s on another must be put on the same basis before heat is calculated.
How long a tank takes to fill
Filling times are a daily use of the conversion. A 1,000-liter tank filled at 45 L/min takes 1,000 divided by 45, or 22.2 minutes. The same flow is 0.75 L/s, and 1,000 divided by 0.75 gives 1,333 seconds, which is the same 22.2 minutes. Having both versions of the rate to hand is useful because some timers count seconds while others count minutes. If you add a second inlet at 15 L/min, the combined flow is 60 L/min, or 1 L/s, and the tank fills in 1,000 seconds, a little under 17 minutes. Check that the pipework can carry the combined flow, and allow for the head of the tank as it fills, since the delivered flow falls as the water level rises.
Reading flow meters and displays
Many flow meters display liters per minute, since that gives a readable number for the household range. Industrial transmitters often send out a 4 to 20 mA signal scaled to a range such as 0 to 120 L/min, and the control system may then display liters per second. If the scale is set wrong by a factor of 60, the pump seems to run at one-sixtieth or sixty times its true rate. A common commissioning check is to compare the display with a bucket and stopwatch test: 30 seconds to fill 20 liters means 40 L/min, or 0.667 L/s. If the meter disagrees, check the unit setting before suspecting the sensor. Flow also fluctuates, so average over several readings. The converter helps with the unit check by showing what the expected figure should be on the other scale.
Average and peak flow in buildings
Water demand in a building is not steady. A shower may use 8 L/min, a kitchen tap 6 L/min and a washing machine fill 12 L/min, and the supply must handle the combination that occurs together. Converting each to liters per second gives 0.133, 0.1 and 0.2, and the sum for all three at once is 0.433 L/s, or 26 L/min. Designers use probability to decide how many fixtures run at once, so the real peak is lower than the full sum in a large building but equal to it in a small house. Knowing the figure on both scales helps when you compare a main rated at 0.5 L/s with a heater rated at 26 L/min. The main carries 0.5 L/s, which is 30 L/min, so only about 4 L/min of headroom is left when all three run together, and any other draw at that moment would pull pressure down.
Rounding, symbols and notation
Round the answer to the precision of the input. A flow of 12 L/min is 0.2 L/s exactly, but 13 L/min is 0.21667 L/s, and quoting 0.2166666667 adds no information. Write the unit as L/s, using a capital L to avoid confusion with the numeral one, and avoid the abbreviations lps or lpm in formal documents because they are ambiguous and not SI. The SI way to write a rate is with a slash or a negative exponent, as in L s⁻¹. When you pass the figure to someone else, include the unit and the basis, for example 0.25 L/s at the pump outlet, so they know where the measurement applies. Rounded numbers that are copied repeatedly can drift, so keep the original reading if later work needs it.
What the converter does not do
This is a unit conversion, nothing more. It does not check whether a pump can produce the flow you entered, whether a pipe can carry it or what the pressure loss will be. It assumes a constant volumetric rate and treats the entered value as an average over the period. Results must be finite numbers. If you need to size equipment, use the converted flow as an input to a proper hydraulic calculation and the manufacturer's published curves, and confirm the data against the applicable plumbing or engineering code. The relationships used here, including the definition of the liter and the minute, come from NIST SP 811 and its Appendix B conversion tables.