Air tools, vacuum pumps and gas supplies
Metric catalogues give the free air delivery of a compressor, the capacity of a vacuum pump or the flow of an oxygen concentrator in liters per minute. American tool ratings, regulator charts and shop manuals use cubic feet per minute. The match matters because a pneumatic tool lists the air it needs, and a compressor has to supply at least that much. Converting L/min to CFM lets you check a European compressor against an American sander or paint gun. The page does this single conversion with the minute kept on both sides, so only the volume unit changes.
Deriving the factor
The international foot is exactly 0.3048 m, so the cubic foot is exactly 0.028316846592 m³, or 28.316846592 liters. One liter therefore equals 1 / 28.316846592 = 0.0353146667215 cubic feet. The minute appears in both units and cancels. The formula is ft³/min = L/min × 0.0353146667215. For mental arithmetic, 28.3 L/min is about 1 CFM, and a quick estimate divides L/min by 28. NIST SP 811 lists the cubic foot and its conversions, which agree with the values used here.
The default 10 L/min
Ten liters per minute is 0.35314666721488597 CFM, a little over a third. That rate resembles the top setting of a home oxygen concentrator, or the output of a small aquarium air pump, and a laboratory gas line feeding a bench instrument may run in the same range. A shop compressor works at a much larger scale, so the useful conversions on this page are usually in the hundreds. The default is still instructive because it shows how large a cubic foot is: it takes more than 28 liters to fill it, so the CFM number is about 28 times smaller than the L/min number.
Matching a compressor to a tool
A portable compressor rated at 200 L/min of free air delivers 7.063 CFM. If a random orbital sander manual asks for 8 CFM at 90 psi, which is an illustrative figure, this compressor falls short for continuous sanding and suits only brief use, with the tank building a reserve between passes. Sanders, grinders and paint guns run continuously, which is why the free air figure matters more than the tank size for them. Always compare the tool figure with the compressor rating at the same pressure, because compressor sheets usually give free air at a specified pressure, often 90 psi. When two ratings are quoted at different pressures, a converted number does not settle the match by itself.
Shielding gas for welding
Welders set argon or mixed gas flow on a regulator, with American regulators often in cubic feet per hour and European ones in L/min. A typical setting of 15 L/min equals 0.530 CFM, and since there are 60 minutes in an hour, 31.8 cubic feet per hour. Multiplying the CFM result by 60 gives the CFH figure that a US regulator dial displays. Check the filler wire maker or welding supplier for the setting that suits your process and nozzle. Welding shops often work across both unit systems, so a European setting in L/min and an American chart in CFH can be compared once the page has done the first step and the factor of 60 the second. Drafts in the workshop blow shielding gas away, which is a reason to raise flow only after checking for air movement.
Vacuum pumps in a workshop
A vacuum chuck, a hobby vacuum chamber for resin casting or a refrigeration vacuum pump lists displacement in L/min or CFM. A pump that moves 85 L/min is 3.002 CFM, close to the 3 CFM units common in HVAC tool bags. Refrigeration technicians choose pumps by CFM for the size of the system, and a 3 CFM pump is a frequent recommendation for residential systems. The converted figure is the free-air displacement. Ultimate vacuum depth is a separate specification and does not follow from the flow figure. Two-stage pumps usually reach a deeper vacuum than single-stage pumps of the same displacement, and larger systems or long hoses take longer to pull down, so a higher CFM rating shortens the time to evacuate a given volume.
Reading medical and fitness gear
Oxygen concentrators and some CPAP humidifier specs are given in liters per minute because clinicians prescribe flow in that unit. Few Americans think of CFM there, so conversions seldom appear in practice, and a travel concentrator manual may list both units to help people who fly with equipment. A case that does arise is comparing a portable concentrator with a bottled oxygen regulator marked in a different unit. At 5 L/min the page gives 0.177 CFM, a flow whose small numbers show why medical gas uses liters. Follow the prescribed liters per minute for treatment; the converted value is for equipment comparison only.
Garage use with a nailer and a tire inflator
A home garage compressor often serves several jobs, and each has its own appetite. Inflating a tire or blowing off a workbench needs little flow, but the compressor refills the tank between uses. A framing nailer fires in short bursts, so its average consumption is low even though the peak is high. A tank compressor listed at 100 L/min of free air, which the page converts to 3.531 CFM, can run such tools all day, while a die grinder or a spray gun that draws air continuously will outrun it. Matching the average continuous demand in CFM to the free air rating, and treating tank size as the buffer for bursts, is the usual way to read a catalogue.
Free air versus actual air
The page converts the volume rate only. Gas volume changes with pressure and temperature, and a compressor rating may refer to free air at inlet conditions, to standard conditions such as SCFM, or to the discharge pressure. A rating in SCFM or Nm³/h refers to a reference state, and converting its volume unit will not change that reference. Make sure both figures share the same basis before comparing them. The result is rounded for display, though the factor stored in the page has twelve significant digits. When a catalogue mixes ratings such as free air delivery, displacement and actual delivery, ask which one the figure describes. Displacement is the swept volume of the pump, while delivered air is lower because of leakage and heating, so the two can differ by a fifth or more on a small machine.