From a hydraulic model to an hourly schedule
Hydraulic models, river gauges and turbine specifications report discharge in cubic meters per second. Operators, billing systems and pump schedules work in hours. A reservoir operator releasing 12 m³/s through a gate needs to know that this moves 43,200 m³ every hour. A treatment works engineer who has a design flow in m³/s from a model has to state it as m³/h when ordering a pump. The conversion is a single multiplication, but it changes the size of the numbers by more than three orders of magnitude, so it is worth doing explicitly and writing the unit with each figure to avoid mistakes in later steps. Irrigation districts do the same when a ditch rider converts a delivery of 0.08 m³/s to 288 m³/h for a farmer who thinks in hours of water.
Multiplying by 3,600
One hour contains 60 minutes of 60 seconds each, which is 3,600 seconds. A flow of one cubic meter every second therefore moves 3,600 cubic meters in an hour. The BIPM SI Brochure lists the hour among the non-SI units accepted for use with the SI and defines it as 3,600 seconds, which makes the factor a definition with no measurement behind it. Because the cubic meter appears on both sides, no volume conversion is involved. A simple check is that 1 m³/s is 3.6 thousand m³/h, so a flow of 0.5 m³/s is 1,800 m³/h and 2 m³/s is 7,200 m³/h.
The default of ten and the flows around it
The default of 10 m³/s becomes 36,000 m³/h. A 0.25 m³/s river intake for a small town is 900 m³/h, and a 1.25 m³/s abstraction is 4,500 m³/h. A canal turnout of 0.02 m³/s delivers 72 m³/h to a field. At the opposite end, a flood flow of 100 m³/s is 360,000 m³/h. The ratio between the two units never changes, so every result on this page ends in the digits of the input followed by hundreds, such as 3,600, 36,000 or 360,000, when the input is a whole number or a simple decimal. A flow of 3.5 m³/s, typical of a medium canal, is 12,600 m³/h, and a 0.6 m³/s industrial cooling circuit is 2,160 m³/h.
Going from hourly flows back to cubic meters per second
To reverse the step, divide by 3,600. A pump station rated at 7,200 m³/h moves 2 m³/s, and a 90 m³/h supply moves 0.025 m³/s. Choose cubic meters per hour as the source and cubic meters per second as the target on the page. Use this direction when you need a figure in SI base units for an equation, since formulas for velocity, power and head loss assume the coherent unit. An hourly figure fed into such a formula without conversion produces an answer 3,600 times too large, an error that propagates unnoticed through a long spreadsheet.
Daily and annual volumes from the hourly flow
Once the flow is in m³/h, multiplying by 24 gives a daily volume and by 8,760 an annual one. A flow of 0.25 m³/s is 900 m³/h, which is 21,600 m³ per day and 7,884,000 m³ per year, assuming it runs continuously. Reservoir operators compare such totals to storage capacity in millions of cubic meters. A release of 12 m³/s for 24 hours removes 1,036,800 m³, a little over one million. These calculations are straightforward, but each step must keep the time basis clear, since a rate and a volume are different quantities.
Hydropower and turbine ratings
Turbine flow ratings are given in m³/s, and the power relation depends on it. Hydraulic power in watts equals density times gravitational acceleration times flow times net head. With 10 m³/s and a 50 m head, hydraulic power is about 4.9 MW, from 1,000 times 9.80665 times 10 times 50. The turbine then converts only part of that to electricity, according to its efficiency. An operator reading a daily water use report in m³/h can restate it in m³/s with this page to apply the formula, and the result then gives power in watts directly. A small run-of-river site with 2 m³/s and a 30 m head has about 588 kW of hydraulic power before losses.
Flow meters that report totals
Many flow meters display a flow rate in m³/h and a running total in m³. If a gauge reports 0.35 m³/s, the equivalent display is 1,260 m³/h. Totalizers add volume over time, so the total increases by 1,260 m³ each hour at that rate. Operators sometimes see two numbers that appear inconsistent because one is a rate and the other a total. Convert the rate to the same time base as the interval you are checking, and compare like with like. A meter that has advanced by 630 m³ in half an hour agrees with the 1,260 m³/h rate. Check the meter manual for the averaging window, because some meters smooth the displayed rate over several seconds.
Choosing digits and avoiding false precision
The result is exact for the digits entered, because multiplying by 3,600 introduces no rounding. The precision is therefore limited by the original measurement. A river discharge of 12.3 m³/s supports 44,300 m³/h, even though the literal product is 44,280. State the result to the same number of significant figures as the input, or one more. In regulatory filings, quote both the original and the converted flow, with the conversion factor visible, so a reviewer can reproduce the figure without ambiguity. Rating tables often round to the nearest 100 m³/h, which is a good guide to how many digits matter.
What the conversion does not do
The page changes the time base of a volumetric flow. It does not convert between volume and mass, correct for temperature or pressure, or determine whether a flow can be sustained. A flow of 10 m³/s is a rate at one moment, and nothing about it guarantees that the source can supply 36,000 m³ each hour for a whole day. For allocation, abstraction and discharge permits, follow the units and averaging periods defined in the permit, such as instantaneous, daily mean or monthly mean, since these can differ for the same river. Reservoir operators typically work with daily means in m³/s, and a short surge can exceed the mean by a wide margin.