Two flow units from two measuring traditions

Cubic feet per minute, abbreviated CFM, is the standard unit for airflow in the United States. Fans, ventilation systems, compressors and dust collectors are rated in it. Imperial gallons per minute belongs to the British tradition of measuring liquid flow, and it still appears in pump catalogs and older specifications from the United Kingdom and some Commonwealth countries. A designer with an airflow figure in CFM and needs a comparable number in imperial gallons, or an engineer comparing a US machine with a UK pump curve, needs the conversion. This page does it with the factor 6.22883545904. The default input of 10 CFM gives 62.2883545904 imperial gallons per minute. Both units measure volume per time, so the conversion is a pure change of volume unit. The page does not interpret the number, and it keeps the time unit, the minute, unchanged.

Building the factor from exact definitions

Both volume units are defined exactly in terms of SI units. The international foot is 0.3048 meter, so a cubic foot is 0.3048 cubed, or 0.028316846592 cubic meters, which is 28.316846592 liters. The imperial gallon was fixed at exactly 4.54609 liters by the UK Weights and Measures Act of 1985, replacing earlier definitions based on the volume of ten pounds of water. Dividing 28.316846592 by 4.54609 gives 6.22883545904, rounded to twelve digits. Both inputs are exact, so the factor can be carried to as many digits as you like. The NIST conversion tables cited on this page list the same relationships. The time unit is the minute on both sides, so it cancels. To go back from imperial gallons per minute to CFM, divide by 6.22883545904, which equals multiplying by 0.1605437.

The default and some round numbers

The default of 10 CFM becomes 62.28835 imperial gallons per minute, which is also 283.17 liters per minute and 4.719 liters per second. Scaling is linear. A flow of 1 CFM is 6.2288 gallons per minute, 40 CFM is 249.1534, 100 CFM is 622.8835 and 400 CFM is 2,491.534. The numbers get large quickly because a cubic foot is about 6.2 times larger than an imperial gallon. Keep that ratio in mind as a check: any conversion in this direction should multiply the number by a little over six. A result smaller than the input signals a reversed direction. A result about 7.5 times larger is the US gallon figure, not the imperial one. Distinguishing the two gallons is the most common reason people consult this page.

The imperial gallon and the US gallon

The imperial gallon holds 4.54609 liters, while the US liquid gallon holds exactly 3.785411784 liters. The imperial gallon is therefore about 20 percent larger. One CFM is 7.480519 US gallons per minute, against 6.228835 imperial gallons per minute. Ten CFM is 74.805 US gpm or 62.288 imperial gpm. A catalog that says GPM without qualification in the United States means the US gallon, while a British document that says gallons per minute usually means the imperial one. Mixing them leads to errors of 20 percent in pump selection, which is large enough to matter. When a specification is ambiguous, look for clues such as the country of origin, the printed liters equivalent or the rated flow in liters per minute, and when in doubt, work in liters or cubic meters per hour.

Air is not water

CFM is almost always used for gases, and imperial gallons per minute for liquids. Converting between them is arithmetically valid, since both are volumes per time, but the physical meaning differs. Air is compressible, so a CFM figure depends on the pressure and temperature at which the volume is measured. Compressor ratings use standard cubic feet per minute (SCFM), referred to defined reference conditions, or actual cubic feet per minute (ACFM) at the operating conditions. A converted figure in imperial gallons per minute of air is a volume at the same conditions, not a statement about mass flow. Use this page when you need the volume flow of a gas or liquid in another unit, and use mass-flow methods when the density matters. When both a gas and a liquid are in play, state the conditions next to the number.

Ventilation sizing example

A common rule of thumb from the Home Ventilating Institute for bathroom exhaust fans is 1 CFM per square foot of floor area for rooms up to about 100 square feet. An 8 by 10 foot bathroom of 80 square feet suggests an 80 CFM fan. In liters per minute, that is 2,265 L/min, and in imperial gallons per minute it is 498.3. The second figure is rarely useful for air, but it illustrates the conversion if you must compare the volume moved per minute with, say, the volume of a tank. A 100 CFM fan moves 622.88 imperial gallons of air each minute. These sizing rules are simplified guidance, and building codes and manufacturer data take precedence. The calculation shows what the converter does without implying that fans are rated in gallons.

HVAC airflow per ton of cooling

A widely used rule in residential air conditioning sets airflow at about 400 CFM per ton of cooling capacity. A 3 ton system would then move 1,200 CFM across the coil. Converting 400 CFM gives 2,491.53 imperial gallons per minute, and 1,200 CFM gives 7,474.60. In metric terms 400 CFM is 11.33 cubic meters per minute, or 679.6 cubic meters per hour. The rule is approximate and system designers use manufacturer data and load calculations, but the figure is a useful reference when checking a unit conversion. If you convert a technician's CFM figure to cubic meters per hour for a European colleague, the result should be about 1.7 times the CFM number, since one CFM is 1.699 m³/h. The check catches slips with the minute-to-hour step.

Water flow in cubic feet per minute

Cubic feet per minute is occasionally used for water as well, usually in hydrology and some irrigation contexts, where flows in cubic feet per second are common. Dividing a flow in cubic feet per second by 60 gives CFM, so 1 cubic foot per second is 60 CFM, or 373.73 imperial gallons per minute. A stream carrying 0.5 cubic feet per second is 30 CFM, which converts to 186.87 imperial gallons per minute. In this setting the gallon is a natural unit for comparing with pumps and tanks. A pump rated at 200 imperial gallons per minute can handle 32.1 CFM. The values are illustrative round numbers. The conversion does not know the fluid, so it applies equally to water, oil or air, as long as the volume is measured under the same conditions.

Rounding and reporting

The factor carries twelve significant figures, but the inputs rarely deserve that many. A fan rated at 100 CFM is a nominal value, perhaps good to two or three digits. Reporting 622.8835459 imperial gallons per minute would imply a precision the rating does not have, and 620 or 623 would be more honest. If you plan to compare or add converted values, carry the full figure through the arithmetic and round only at the end to avoid accumulating rounding errors. For safety margins or equipment selection, round in the conservative direction: a pump selected for a requirement should be rated above the converted figure, not below it. The page performs exact arithmetic on what you enter, and the care in choosing significant figures is the user's task.

Duct velocity from a CFM figure

Airflow in CFM becomes a velocity once you divide by the duct cross-section. Take 400 CFM in a round duct of 6 inch diameter, which has a radius of 0.25 foot and an area of about 0.196 square foot. The velocity is 400 divided by 0.196, or about 2,037 feet per minute, which is roughly 10.4 meters per second. The same flow in other units is 11.33 cubic meters per minute, or 2,491.5 imperial gallons per minute. Only the CFM and area are needed for the velocity, but converting the flow lets you compare the duct with a metric specification. Higher velocities create noise and pressure loss, which is why designers choose duct sizes to hold velocity within a range suited to the room served. The example is a rough illustration, not a design rule for any code.

Other metric equivalents

The same flow has several metric forms, and it helps to know them together. One CFM is 28.316846592 liters per minute, 0.4719474432 liters per second and 1.699010796 cubic meters per hour. So 100 CFM is 2,831.68 L/min, 47.19 L/s and 169.9 m³/h, and also 622.88 imperial gallons per minute. If you are checking a table that lists several units, the ratios between columns should match these factors. The imperial gallon column is the smallest multiple of the CFM at 6.23, then the US gallon column at 7.48, then the liter column at 28.3. Seeing the pattern makes errors visible: a column that is out of order points to a copying mistake. The converter lets you set any of the listed units as the destination to confirm each factor.

Checking a conversion with a known volume

A simple test uses a tank. A tank of 1 cubic foot holds 28.317 liters, which is 6.2288 imperial gallons. If a flow of 1 CFM fills it in one minute, then the flow in imperial gallons per minute must be 6.2288. Doubling the flow halves the time and doubles the number. Filling a 35 cubic foot tank, about 218 imperial gallons, at 10 CFM takes 3.5 minutes, and the flow of 62.29 imperial gallons per minute gives the same 3.5 minutes after dividing 218 by 62.29. If your own tank test gives a different time, either the flow differs from the rating or a unit slipped. The test needs no formula beyond the definitions, which makes it a reliable way to confirm that the factor in the converter matches your reasoning.

What the converter does not do

Only the unit changes here. Entering 400 CFM does not correct the flow to standard conditions, and the page has no way to know whether a figure is SCFM or ACFM, so that label has to come from the source. Fan, pump and duct selection needs manufacturer data, system curves and the codes for the project.