From single-pixel charge to capacitor charge
Microcoulombs are the scale of the charge on a modest capacitor, of a static discharge or of a small electrostatic experiment. Femtocoulombs are the scale of a tiny sensor signal. A designer who reads a detector spec in fC and a capacitor charge in µC may need both in one unit to compare the signal with the charge that sloshes around the circuit. This page converts fC to µC with a single factor of 10^−9 and, in the other direction, µC to fC with a factor of 10^9. Photodiode and CCD readouts, ADC sample capacitors and touch controllers all deal with charges across this range, and a lab comparing a particle detector with the capacitor in its bias network meets the same two units in one document.
Nine orders and the Greek mu
Femto is 10^−15 and micro is 10^−6, so one microcoulomb is 10^9 fC, and one femtocoulomb is 10^−9 µC. The SI Brochure defines both prefixes, which keeps the factor exact. The micro prefix uses the Greek letter µ, written u in plain text, so uC reads as microcoulomb. Take care not to read it as a capital C for some other unit. The page output for the default, 1.0000000000000002e-8, is binary rounding and should be read as 1 × 10^−8 µC. The two-step route is fC to nC, a factor of 10^−6, then nC to µC, a factor of 10^−3, which gives the same 10^−9.
Ten femtocoulombs in microcoulomb decimals
The default entry returns 1 × 10^−8 µC, which is 0.00000001 µC. In this form, a 10 fC pulse is one hundred-millionth of a microcoulomb, and many orders below the charge of an ordinary capacitor. Entering 2,500 fC gives 2.5 × 10^−6 µC, and 1 million fC, which is 1 nC, gives 0.001 µC. These numbers help you estimate which signals are lost when they ride on a larger charge, and why sensors integrate over a short time. A 5,000 fC pulse, which is 5 × 10^−6 µC, arriving over about a microsecond is a mean current of 5 µA. A 1 nF sample capacitor charged to 2.5 V holds 2.5 nC, which is 0.0025 µC or 2.5 × 10^6 fC.
Charge on a decoupling capacitor
The relation Q = C × V gives the charge on any capacitor. A 100 nF capacitor at 5 V holds 500 nC, which is 0.5 µC, or 5 × 10^8 fC. A 10 µF capacitor at 3.3 V holds 33 µC. Compared with that, a detector signal of 5,000 fC, or 5 × 10^−6 µC, is smaller by a factor of 100,000 against the 0.5 µC on the decoupling capacitor. That ratio is why the signal path needs careful layout and shielding, and why you cannot let the supply bounce into the sensing node. A 50 mV bounce across the same 100 nF capacitor moves C × ΔV = 5 nC, or 0.005 µC, which is still a thousand times the 5,000 fC signal.
Static electricity and the human body
A person can build up static charge by walking on carpet. A common model gives the body a capacitance of about 100 pF. Charged to 5,000 V, that capacitance holds Q = 10^−10 × 5,000 = 5 × 10^−7 C, which is 0.5 µC, or 5 × 10^8 fC. A much smaller charge, in the nanocoulomb range, is enough to damage some electronic parts if it discharges through them, which is why handling rules call for grounding. The numbers here are illustrative, and standards define test models for electrostatic discharge in detail. The widely used human body model pairs a 100 pF capacitor with a 1.5 kΩ resistor, so the 5 kV arithmetic above matches its capacitor, while the resistor limits the peak current.
Microcoulomb values restated as femtocoulombs
To convert microcoulombs to femtocoulombs, select µC as the From unit. 0.47 µC returns 4.7 × 10^8 fC, 1 µC returns 10^9 fC and 33 µC returns 3.3 × 10^10 fC. This direction is the one you need to express a capacitor charge in the unit of a detector spec. Because the digits are many, use scientific notation when writing the result into a report, and check one value by hand: 0.47 × 10^9 is 4.7 × 10^8. A charge of 4.7 µC equals 4.7 × 10^9 fC, and 0.01 µC equals 10^7 fC, so each shift of the decimal point in the microcoulomb value moves the exponent by one.
Intermediate units
The unit list on the page includes coulombs, millicoulombs, nanocoulombs, picocoulombs and kilocoulombs, so you can step down from µC to fC in three moves of 1,000. 1 µC is 1,000 nC, which is 10^6 pC, which is 10^9 fC. The stepping approach is a quick way to catch typing errors and builds the habit of reading prefixes as exponents. If a direct conversion and a stepped one disagree, one of the entries has a wrong power of ten.
Digits and noise
Report the converted value with the same significant figures as the original reading. If a vendor lists a pulse charge in electrons, multiply the count by 1.602 × 10^−4 to get femtocoulombs, then by 10^−9 for microcoulombs: 100,000 electrons are 16.02 fC, which is 1.602 × 10^−8 µC. A readout that integrates for a longer time collects more signal charge and more noise charge, so quote the integration time with the figure. Detector systems also add a pedestal or offset that has to be subtracted before the conversion, and the page cannot know that offset. Keep raw and corrected values clearly labeled in your records. A reading of 2,500 fC with two digits is 2.5 × 10^−6 µC. Charge measurements this small are limited by noise and by the input capacitance of the amplifier, so many digits rarely mean much. The conversion adds no uncertainty, but it also does not remove any. For a pulse of 2,500 fC, a reasonable report is 2.5 × 10^−6 µC together with the bandwidth of the measurement, since a wider bandwidth admits more noise charge.
Voltage, stored energy and discharge hazard excluded
The page changes the unit of a charge. It does not compute voltages, currents or stored energy, judge whether a discharge is hazardous, or evaluate any electrostatic protection scheme. It does not calculate installation limits, equipment ratings, protection or compliance. Follow the applicable standard and the equipment documentation for those matters.