Heat in one unit and work in another

The BTU and the foot-pound are both units of energy that grew out of the English system. The BTU measures heat and appears in the ratings of furnaces, air conditioners, boilers and fuels. The foot-pound force measures mechanical work: one foot-pound is the work done by a force of one pound-force acting through a distance of one foot. Because heat and work are forms of the same thing, energy, they can be converted into each other, and this converter does so using exact definitions. Enter a value in BTU, keep the target of foot-pounds, and the output is the equivalent mechanical energy. The default of 10 BTU converts to about 7,781.69 foot-pounds. The menu includes joules, kilojoules, kilowatt-hours, calories and electronvolts, so it also serves as a general energy converter, with BTU and foot-pounds as the pair on this page.

Where 778.169262266 comes from

The factor is a ratio of two definitions expressed in joules. The International Table BTU is defined as exactly 1,055.05585262 joules. The foot-pound force is derived from the international foot, which is exactly 0.3048 meter, the international avoirdupois pound, which is exactly 0.45359237 kilogram, and standard gravity, 9.80665 meters per second squared. Multiplying them gives 1.3558179483314004 joules per foot-pound. Dividing 1,055.05585262 by that figure gives 778.169262266. Both of these definitions are listed in the NIST guide cited by this page. Because it is a ratio of defined values, the factor is exact to the digits shown. One BTU is therefore a little more than 778 foot-pounds, which means that a pound lifted 778 feet carries about as much energy as a pound of water warmed by one degree Fahrenheit.

The default example: 10 BTU

Ten BTU multiplied by 778.169262266 is 7,781.69262266 foot-pounds. In joules, that is 10,550.5585 J, a little over 10 kJ. To picture the amount, 7,781.7 foot-pounds equals lifting a 100-pound weight about 78 feet, or lifting a 1,000-pound weight about 7.8 feet. In heat terms, 10 BTU is the amount that raises 10 pounds of water by 1 °F, or about 1 pound of water by 10 °F. The converter lets you slide between the two views quickly. Smaller inputs scale in proportion. Half a BTU is 389.0846 foot-pounds, and 100 BTU is 77,816.9262 foot-pounds. The factor is large because the BTU is a large unit relative to the foot-pound, and that ratio is a useful number to keep in mind.

Which BTU is it?

There is more than one BTU. The page uses the International Table BTU, abbreviated BTU IT, which equals 1,055.05585262 joules. Other definitions exist. The thermochemical BTU is 1,054.350 joules, and BTUs tied to the heat required to warm water at specific temperatures, such as 39 °F or 60 °F, differ by a fraction of a percent. The differences are about 0.07 percent between the thermochemical and International Table versions, which rarely matters in estimates, but matters if you compare against a source that uses a different one. Most engineering, HVAC and fuel data in the United States uses a BTU close to the International Table value. If a source does not state which BTU it uses, the difference is usually below other uncertainties, but the page labels its choice so that the factor is traceable.

Foot-pounds of work and foot-pounds of torque

The foot-pound force as a unit of energy shares a name and dimension with the pound-foot, the English unit of torque. The two are not the same quantity. Energy is a force acting through a distance, while torque is a force acting at a lever arm. The units multiply the same two things, which is why they look alike, but a torque of 100 lbf·ft does not represent 100 ft·lbf of stored energy. Automotive and tool specifications use torque, often written as foot-pounds, so a torque wrench setting is not an energy to be converted into BTU. This converter treats the foot-pound as energy. Applying it to a torque value gives a number that has no physical meaning, so check which quantity your source describes before converting.

Horsepower and the mechanical equivalent of heat

Mechanical horsepower was defined as 550 foot-pounds per second, or 33,000 foot-pounds per minute, which makes one horsepower-hour equal to 1,980,000 foot-pounds. Dividing by 778.169 shows that one horsepower-hour equals about 2,544 BTU. This is the old rule that an engine of one horsepower, running for an hour, delivers the equivalent of roughly 2,544 BTU as work. The numerical link between heat and work was established experimentally by James Prescott Joule, whose paddle-wheel experiments in the 1840s were refined by 1850 to a figure close to 772 foot-pounds of work per BTU of heat. The value you get from modern definitions, 778.17, is slightly higher, a reflection of improved measurement. This relationship is the historical origin of the idea that heat and work are interchangeable forms of energy.

HVAC and furnace ratings

The BTU matters most in heating and cooling, where ratings are given per hour. A cooling capacity of one ton of refrigeration is 12,000 BTU per hour, which is roughly 3.517 kW. This converter works with energy, not power, so a rate in BTU per hour needs to be multiplied by the hours to produce energy first. Twelve thousand BTU, the heat absorbed in one hour at one ton, equals 9,338,031.15 foot-pounds, or about 12.66 megajoules. Dividing by 3,600 seconds gives the power in foot-pounds per second, about 2,594. The example shows how to treat a rating as a rate over a defined period. Converting to mechanical units is rarely needed by an installer, but it is useful in teaching, and in comparing the energy content of fuels to the work an engine can extract.

Using the reverse direction

To go from foot-pounds to BTU, set the source to foot-pounds and the target to BTU. A weight of 100 pounds lifted 10 feet represents 1,000 foot-pounds, which equals 1.285 BTU. A spring that stores 500 foot-pounds holds about 0.64 BTU. These reversals show how small the mechanical quantities are compared with heat. Lifting a heavy object in a human-scale operation involves only a few BTU, while heating a room involves thousands. That mismatch is why heat engines are inefficient to describe in mechanical units and why the BTU is the preferred unit in energy bills. A single gallon of gasoline contains over 100,000 BTU, which is about 90 million foot-pounds, an amount that explains why fuel is such a compact store of energy.

Why the number looks so large

Newcomers often ask why one BTU equals nearly 800 foot-pounds. The answer is the size of the units. A foot-pound is the energy to lift a one-pound weight by one foot, which is tiny. A BTU is the heat to warm a pound of water by one degree, and the specific heat of water is so high that warming water takes a lot of energy compared with lifting it. In SI terms, 1 BTU is about 1,055 J and 1 ft·lbf is about 1.356 J, a ratio of 778. Thinking in joules helps: the BTU is a thousand-joule unit, and the foot-pound is a joule-scale unit. The result is therefore not surprising, and a result near 1 or near 1,000,000 would signal a problem with the unit or the input.

Heating water: a sanity check

The definition of the BTU gives a way to test the conversion with a familiar task. Heating a gallon of water, about 8.34 pounds in the US gallon, by 10 °F takes roughly 83.4 BTU, using the rule that one BTU warms one pound of water by one degree Fahrenheit. Multiply by 778.169 to get 64,900 foot-pounds, or about 88 kJ. If you could capture that energy as work, it would lift a 1,000-pound object about 65 feet. The check shows how much energy a modest temperature change involves. The specific heat of water is a rounded textbook value, and the exact number of BTU depends on the starting temperature, so treat the example as an estimate. The converter, in turn, applies the same factor to whatever BTU value you give it.

Fuels measured in BTU

Fuel energy is often stated in BTU per unit, and converting to foot-pounds gives a sense of the mechanical work that fuel could in principle supply. A cubic foot of natural gas contains roughly 1,000 BTU, and a gallon of gasoline contains roughly 114,000 to 125,000 BTU depending on whether the lower or higher heating value is used. Taking 100,000 BTU as a round figure, the work equivalent is 77,816,926 foot-pounds. A real engine converts maybe 25 to 35 percent of fuel energy into work, so a fraction of that figure is available. The numbers are typical, rounded values, not specifications for a given fuel. Heating values depend on composition, and suppliers publish the figures for their product. The converter gives the energy equivalence, and the efficiency discussion is separate.

Rounding and significant figures

The factor has twelve significant figures, and the output may too. Most BTU values you meet have two or three significant figures, such as 12,000 BTU for an air conditioner rating or 80,000 BTU for a furnace. Report the result with a similar number of figures. For 12,000 BTU, writing 9.3 million foot-pounds is honest, while 9,338,031.147 implies a precision the rating does not have. If you need a precise intermediate value for a longer calculation, carry the full figure and round at the end. When going back from foot-pounds to BTU, the same rule holds. The exactness of the factor is a property of the definitions, and it does not make the input more accurate. A sloppy input yields a sloppy output, however many digits the screen shows.

Heat is not recoverable as work

The tool converts one energy amount between two units. It does not compute how much work a heat engine can extract, which depends on temperatures and efficiency, nor does it size equipment, check ratings or assess installation, protection or compliance. A heat quantity expressed in foot-pounds is not mechanical work that you can obtain in practice, because the second law of thermodynamics limits the conversion of heat to work. The page converts the units and nothing else. For power ratings, convert energy per time with a power converter, and keep the BTU definition consistent with your source.