Two ways to count the same charge

Batteries and chargers are rated in ampere-hours, or in milliampere-hours for small devices, because that unit matches how people think about a battery: how much current it can supply and for how long. Physics and electrochemistry texts use the coulomb, the SI unit of electric charge, because it plugs directly into formulas for capacitors, electrolysis and the movement of individual charge carriers. Both units measure the same quantity, the total electric charge that passes a point. This converter turns ampere-hours into coulombs. Enter the capacity on a battery label, keep the default destination of coulombs, and the result is the charge in the unit that science and engineering formulas expect. The menu also contains milliampere-hours, millicoulombs, microcoulombs, nanocoulombs, picocoulombs, femtocoulombs and kilocoulombs, so the same tool can move between small laboratory charges and large battery capacities in either direction.

Where the factor of 3,600 comes from

The coulomb is defined through the ampere: one coulomb is the charge carried by a steady current of one ampere in one second. Charge is current multiplied by time, so a battery that supplies 1 A for 1 s has delivered 1 C. An hour is 3,600 seconds, which means 1 A flowing for an hour delivers 3,600 C, and 1 Ah equals 3,600 C. The relationship is exact. In the 2019 revision of the SI, the ampere was redefined by fixing the elementary charge at exactly 1.602176634 times 10 to the minus 19 coulomb, and the coulomb follows from that. The factor of 3,600 is untouched by the redefinition because it comes only from the number of seconds in an hour. For the reverse direction, divide coulombs by 3,600, so 7,200 C is 2 Ah. The sources cited on the page are the NIST and BIPM unit definitions for electric charge.

The default example: 10 Ah

The default value of 10 Ah converts to 36,000 C. That capacity is typical of a small deep-cycle battery or a large portable power bank, and it is a useful size to picture. If the battery supplies a steady 2 A, it lasts 5 hours, and the charge drawn in that time is the whole 36,000 C. If it supplies 10 A, it lasts one hour. The coulomb figure does not change with the rate of discharge in the ideal case, which is a point worth separating from real behavior. In practice, a battery discharged quickly delivers less total charge than one discharged slowly, an effect described for lead-acid cells by Peukert and observed in other chemistries as well. The converter treats the rating as a fixed charge, so use the capacity that applies to your discharge rate when that matters.

Phone, laptop and car batteries

Smaller devices use milliampere-hours, where 1 mAh equals 3.6 C. A phone battery rated at 4,000 mAh holds 4 Ah, which converts to 14,400 C. A typical lead-acid car battery rated at 60 Ah holds 216,000 C, and a 100 Ah deep-cycle battery in a boat or camper holds 360,000 C. A 0.5 Ah camera cell holds 1,800 C, and a 2.5 Ah power-tool cell holds 9,000 C. These capacities are illustrative round numbers, not specifications for any particular product. The coulomb counts are large because a coulomb is a small quantity of charge. A lightning flash, by comparison, is often described as transferring a few coulombs to a few tens of coulombs in a fraction of a second, so a phone battery holds hundreds of times more charge than a flash moves. The time over which the charge moves, not the amount, makes the flash dangerous.

Charge is not energy

Ampere-hours and coulombs tell you how much charge a battery can move. They do not tell you how much energy that charge carries, because energy depends on voltage as well. Energy in joules equals charge in coulombs times voltage in volts. A 4 Ah phone battery at a nominal 3.7 V holds 14,400 C times 3.7 V, which is 53,280 J, or 14.8 Wh. A 60 Ah car battery at a nominal 12 V holds 216,000 C times 12 V, which is 2,592,000 J, or 720 Wh. So a battery with a smaller ampere-hour rating can store more energy if its voltage is higher. For that reason, comparing batteries by ampere-hours alone is only fair when the voltage is the same. If you need an energy figure, multiply the converted coulombs by the voltage, or multiply ampere-hours by volts to get watt-hours directly.

Faraday's constant and electrolysis

In electrochemistry the coulomb connects directly to amounts of substance. The Faraday constant, about 96,485.33 C per mole of electrons, gives the charge carried by one mole of electrons. Dividing 3,600 C by it shows that 1 Ah corresponds to about 0.0373 mole of electrons. Electroplating and electrolysis use this relationship. Copper ions carry two electron charges each, so one ampere-hour deposits about 0.0373 divided by 2 moles of copper, roughly 1.19 g, assuming perfect efficiency and a molar mass of about 63.5 g per mole. Real processes lose some charge to side reactions, so the actual mass is lower. The figures are idealized illustrations of the method. The coulomb is the unit that makes the arithmetic direct, which is a good reason to convert a charger or rectifier rating from ampere-hours before applying Faraday's laws.

Capacitors and small charges

At the small end of the scale, charge is measured in microcoulombs, nanocoulombs and picocoulombs. A capacitor holding charge Q at voltage V stores a charge equal to its capacitance times the voltage. A 1,000 microfarad capacitor charged to 10 V holds 10 millicoulombs, which is 0.01 C and about 0.0000027778 Ah. Those figures are a reminder that capacitors hold far less charge than batteries, even when they can deliver it very fast. Converting a battery rating to coulombs makes this comparison direct. A 1 Ah battery holds 3,600 C, which is 360,000 times the charge on that capacitor. The menu options for smaller units help when you work on that end, and the converter returns the same exact factor-of-ten relationships between the SI prefixes, so changing between millicoulombs and microcoulombs involves only powers of 1,000.

Coulomb counting in battery monitors

Many battery management systems and fuel gauges estimate state of charge by coulomb counting. A sensor measures the current, and the controller adds up current times time to track the charge that has flowed in or out. If the controller integrates 2 A for 30 minutes, the charge is 2 times 1,800, which is 3,600 C, or 1 Ah. Over time, small measurement errors accumulate, so most systems recalibrate against voltage at known points, such as when the battery is full. Understanding the unit conversion helps when reading the data from a monitor that logs coulombs or when comparing it with an ampere-hour rating. If the log shows 7,200 C drawn from a battery rated at 10 Ah, that is 2 Ah, or 20 percent of the nominal rating.

Capacity ratings and temperature

An ampere-hour rating is a statement about conditions. Manufacturers specify capacity at a discharge rate, often written as C/20 for a 20-hour discharge in lead-acid batteries, to a cutoff voltage and at a reference temperature, commonly about 25 °C. A battery used in the cold delivers less charge than its label, and a battery that has aged holds less than when new. The conversion to coulombs is exact, but the capacity you put into it is a nominal figure. Planning with 80 percent of the nominal rating is a common conservative habit for lead-acid batteries that should not be deeply discharged. For 100 Ah that leaves 80 Ah, or 288,000 C. This is a rule of thumb for illustration, and the right limit depends on the chemistry and the manufacturer's guidance.

A runtime example in coulombs

Coulombs make runtime arithmetic easy when the load is described in amperes. A 12 V pump draws 4 A, and you have a battery that holds 216,000 C. Dividing the charge by the current gives 54,000 seconds, which is 15 hours. The same sum in ampere-hours uses 60 Ah divided by 4 A, which also gives 15 hours, and the agreement shows that the two units are interchangeable once you convert. For a pulsed load, coulombs are often easier. A sensor that wakes for 2 seconds at 50 mA uses 0.1 C per cycle. At 100 cycles a day, that is 10 C, and a battery of 0.5 Ah, which holds 1,800 C, could in principle supply 180 days of operation. Real devices add sleep current, self-discharge and capacity loss in the cold, so the answer is an upper bound for planning, not a prediction.

Units for very large and very small charge

The prefixes on the menu span a wide range. A kilocoulomb is 1,000 C, so a 10 Ah battery holds 36 kC. A millicoulomb is 0.001 C, a microcoulomb is 0.000001 C, and a nanocoulomb is 0.000000001 C. Static electricity involves charges of nanocoulombs to microcoulombs. A charged human body is often modeled as a capacitor of about 100 pF, which at 10 kV holds 1 µC (an illustrative case). Particle physics works with the elementary charge, about 1.602 times 10 to the minus 19 C, so a single coulomb corresponds to about 6.24 times 10 to the 18 elementary charges. Chemistry bridges the scales through the Faraday constant. Because every unit in the menu is a power of 1,000 of the coulomb, apart from the ampere-hour, the converter is exact in all of them, and the one special case is the factor of 3,600.

What the converter does not do

The converter changes units of electric charge and nothing more. It does not estimate runtime, which needs the load current, or energy, which needs voltage, or the effects of temperature, age and discharge rate on capacity. It does not size wiring, fuses or chargers, and it does not check any equipment against safety ratings, standards or regulations. Batteries can deliver very high currents, and a fault can cause fires or burns, so installation and protection decisions belong to the equipment documentation and a qualified person. Use the result as the same charge expressed in another unit, and combine it with voltage, current and time separately when your question is about energy or duration.