When a terawatt is the natural unit

A terawatt is 10^12 W. Individual power stations are measured in megawatts or gigawatts, so terawatts show up when whole countries, continents or the entire world are compared. The page default of 10 BTU/h is 2.9307e-12 TW, a reminder that the two units sit about thirteen orders of magnitude apart. The pair is relevant for energy analysts who start with fuel statistics in BTU, as US government energy data often does, and want an average power for comparison with another country reported in SI. Dividing a yearly quantity by the hours in a year turns an energy into a rate, and that rate can then be stated in terawatts.

The constant and its reverse

One International-table BTU is 1,055.05585262 J, so one BTU per hour is 0.29307107017222 W. A terawatt is a trillion watts, which makes the factor 2.93071070172e-13 TW per BTU/h. For the other direction, one terawatt is 3.412141633e12 BTU/h, about 3.4 trillion. For a global-scale illustration, entering 20 TW as an illustrative world-scale average power returns about 6.8243e13 BTU/h. The values come from the BTU definition in NIST SP 811 and the SI prefix tera in the BIPM SI Brochure, so the multiplication has no empirical content of its own.

Turning a quad into an average power

US energy reports often use the quad, one quadrillion BTU, or 1e15 BTU. Spread over a year of 8,766 hours (365.25 days), one quad is 1.14077e11 BTU/h, and the converter gives 0.0334327 TW for that rate, which is about 33.4 GW. In other words, every quad of annual energy use corresponds to a continuous power of roughly 33 GW. Multiply by the number of quads to scale it up. This is the quickest way to translate an annual national energy figure into an average rate that can be compared with the capacity of power stations, since a 1 GW station running continuously supplies about 0.03 quad per year in energy terms.

The reverse direction for big power figures

Starting from terawatts shows how big the numbers get in BTU. One terawatt equals 3.4121e12 BTU/h, so a nation using an average of 3 TW, as an illustrative figure, burns or converts about 1.02e13 BTU every hour. This is the reverse of the quad calculation and checks it, since 1.02e13 BTU/h times 8,766 hours is 8.97e16 BTU, about 90 quads per year. The page does not know about any particular country, so any real average power must come from a published statistic. Use the sign of the exponent as your first check. A TW figure converted to BTU/h should have a larger exponent, and a BTU/h figure converted to TW should have a smaller one.

Prefix scale from kilowatt to terawatt

The chain of prefixes runs kilowatt (10^3 W), megawatt (10^6), gigawatt (10^9) and terawatt (10^12). A common slip is to confuse a thousand with a million when stepping through it. Households are rated in kilowatts, a large reactor delivers roughly a gigawatt, and only the sum of many stations reaches the terawatt range. On this page the conversion from BTU/h to GW multiplies by 2.93e-10, and from BTU/h to TW by 2.93e-13, so the TW answer is a thousand times smaller. In text, write TW with capital T and capital W. A lowercase t would be read as a metric ton in some contexts, and TW is the only accepted symbol for terawatt.

Power rate versus annual energy

Statistics for energy supply often arrive as energy per year, in joules, BTU or kilowatt-hours, while the unit on this page is power. They are connected through time. A terawatt sustained for a full year is 8,766 terawatt-hours with the 365.25-day year used above, or about 31.6 exajoules. Mixing a rate and a quantity is a typical error in reports. If you take a figure such as 100 quads and enter it as BTU per hour, the result is meaningless because the unit lacks the time dimension. Divide by hours first, then convert. The converter does not know the time period behind your figure, so you must supply it.

Digits for quad-scale BTU/h figures

Energy statistics at this scale are rounded to three or four digits, and national figures carry real uncertainty, including the choice of how primary energy is counted. Because the multiplier is exact, the correct number of digits in the answer equals the number in the source. Reporting 0.0334327 TW from a one-quad input suggests more precision than a rounded 1.00 quad deserves, and 0.0334 TW is more suitable. Keep scientific notation in tables that mix very large and very small numbers, and always state the BTU definition used, since a thermochemical BTU would change the factor by about 0.07 percent, a difference larger than the precision of some inputs.

Where annual quad figures come from

The US Energy Information Administration publishes national energy totals in quadrillion BTU, and many American summaries repeat them in quads. A reader who wants to place such a figure next to an international number in terawatts or exajoules needs the two steps shown above: divide by the hours in the year and apply the factor on this page, or multiply by 1.05505585262 to get exajoules per quad. One quad is about 1.055 EJ. For example, an illustrative total of 90 quads is about 95 EJ per year, or about 3.0 TW averaged over 8,766 hours. Always check whether a source counts primary energy, delivered energy or electricity only, because the same country can show very different totals depending on that choice.

Cooling capacity on a grand scale

Heating and cooling loads give another way to feel the size of a terawatt. A ton of refrigeration is 12,000 BTU/h, so one terawatt of cooling, 3.412e12 BTU/h, equals about 284 million tons of refrigeration. A typical home central unit is two to five tons, which shows how many installations a terawatt represents. Such comparisons help when a study reports the heat rejected by a sector of the economy in terawatts and you want to relate it to equipment sizes you already know. The converter handles only the first step, BTU per hour to terawatts. The division by 12,000 for tons is simple, but keep the refrigeration ton separate from the shipping ton or the metric tonne. If a source gives the heat rejected in terawatts, the converter works in reverse as well, so you can express that load in BTU per hour and compare it with equipment ratings that are printed on nameplates in the US.