Coulomb counting and why mC shows up
A fuel gauge chip estimates how full a battery is by adding up the current that flows in or out. Current in milliamperes multiplied by time in seconds is a quantity in millicoulombs, since 1 mA for 1 s is 1 mC. The firmware keeps that running total in a register, and data sheets and logs often print it in mC or in raw counts of mC. A battery rating, meanwhile, is in ampere-hours. To compare the two, you convert one to the other, and this page does it from the ampere-hour side. It is a practical check when you debug a gauge that reports a total of a few million millicoulombs and you need to know whether that is a realistic fraction of the cell. Developers who read a gauge over a serial interface often meet these numbers as raw integers and want to turn them into something readable.
Where 3,600,000 comes from
One ampere-hour equals 3,600 coulombs because an hour has 3,600 seconds and the coulomb is the ampere-second. Each coulomb holds 1,000 millicoulombs, so one ampere-hour is 3,600,000 mC. For the default of 10 Ah the page returns 36,000,000 mC. The easy way to remember the factor is the milliampere-hour: 1 mAh is exactly 3,600 mC, which follows from 1 mA flowing for 3,600 s. Multiply 3,600 by the number of mAh, or by 1,000 times the number of Ah, and you arrive at the same figure. All of these steps use exact definitions, so there is no rounding. Reading the number as 3.6 million per ampere-hour also tells you that a 100 mAh drain is 360,000 mC, which makes a handy mental anchor.
A worked gauge reading
Suppose a gauge reports that a 2,000 mAh cell has delivered 5,400,000 mC since the last full charge. Dividing by 3,600 gives 1,500 mAh, which means 75 percent of the rated charge is gone and about 500 mAh remains in an ideal case. The reverse also helps: a load of 5 mA for two minutes, or 120 s, draws 600 mC, which is about 0.1667 mAh. Using millicoulombs avoids rounding in the integration, since a gauge that stored only whole mAh would lose small drains entirely. It is the same reason chip designers pick the smallest convenient unit for a running total. The same division handles any total your gauge reports: divide by 3,600 for mAh or by 3,600,000 for Ah, and compare the answer with the rated capacity on the cell label.
Quarter and half ampere-hours
Smaller values show the scale. A quarter of an ampere-hour is 900,000 mC, half an ampere-hour is 1,800,000 mC and one tenth is 360,000 mC. A 1 mAh drain is only 3,600 mC, so even a busy sensor that draws 20 mA for a minute uses 1,200 mC, a third of a milliampere-hour. When you read data from a logger that stores mC, these anchors let you spot numbers that are off by a power of ten. A reading ten times too large usually means that the prefix was misread rather than that the battery has an unusual capacity. For a 2,000 mAh cell the full rating is 7,200,000 mC, a useful number to keep next to a gauge log.
Reverse direction and the gauge register
To go from millicoulombs to ampere-hours, divide by 3,600,000. A total of 1,800,000 mC is 0.5 Ah, and 3,600 mC is 0.001 Ah or 1 mAh. Registers that count mC also have limits. A 32-bit unsigned register tops out above 4.29 billion, which is about 1,193 Ah, far above any phone battery, whereas a 16-bit register at 65,535 mC holds under 20 mAh and would overflow quickly. Firmware therefore scales its counts, and the scale may not be 1 mC per count. When you use a log, check the data sheet for the weight of one count before applying this page.
Sampling rate and rounding in a running total
A gauge that samples current every 250 ms, with a reading of 40 mA, adds 40 × 0.25 = 10 mC each sample. Over an hour that is 14,400 samples and 144,000 mC, or 40 mAh, which matches 40 mA for one hour. If the gauge drops the fractional part of every sample, the totals drift. A reading of 3.9 mA truncated to 3 mA loses about 23 percent of the drain. Storing the total in the smaller unit, millicoulombs or even microcoulombs, limits that rounding. This is the reason you may see charge counters in unusual units, and why converting back to ampere-hours should be the final step of a calculation.
Millicoulombs outside batteries
Millicoulombs also appear in pulsed power. A 100 µF camera flash capacitor charged to 300 V holds 30 mC. Those events last milliseconds, not hours, so comparing them with a battery in ampere-hours is a way to see how short and intense they are. Even a pulse of 1,000 mC is only 0.0002778 Ah, less than a third of a milliampere-hour of battery charge. Photographic flash and capacitor discharge work uses the same arithmetic: charge equals capacitance times voltage, so 100 µF at 300 V gives 0.03 C, or 30 mC. Divide by 3,600,000 to see that this equals about 0.0000083 Ah.
Choosing between mC, mAh and Ah
Use the unit that matches the scale you work at. Milliampere-hours suit batteries of a few thousand mAh, ampere-hours suit larger packs, and millicoulombs suit instruments that integrate current over seconds. When you share a value, state the unit in the same cell or sentence and avoid shorthand such as mC meaning milliamp-charge, which does not exist. A charge of 5,400,000 mC, 1,500 mAh and 1.5 Ah is one and the same quantity, and a record that lists all three side by side lets a reader confirm the arithmetic in seconds. A battery management firmware document is a good place to apply that habit, since it often mixes all three.
Charge only, not runtime or energy
The page changes the unit of a charge and stops there. It does not compute energy, estimate runtime, or correct for temperature, age or discharge rate. In line with the page assumptions, it does not calculate installation limits, equipment ratings, protection, material response or compliance. If a gauge reading disagrees with a measured capacity, the converted number will show the disagreement but cannot say whether the gauge, the cell or the load is the cause. Use the manufacturer data and a calibrated measurement for that.