Force along a line, or energy over an area
Surface tension is the force acting along a line in the surface of a liquid, per unit length of that line, so its SI unit is the newton per meter, N/m. The same unit is joules per square meter, because the energy needed to enlarge a surface by one square meter equals the force per length. Water at 20 degrees Celsius has a surface tension of about 72.8 mN/m, which is 0.0728 N/m. It causes drops to form, lets small insects stand on a pond, and makes a thin tube draw liquid upward. The quantity belongs to the interface between two phases, usually a liquid and air, and different partner phases give different values.
Dynes per centimeter equal millinewtons per meter
The older centimeter-gram-second unit is the dyne per centimeter. One dyne is 10^-5 N and one centimeter is 10^-2 m, so 1 dyn/cm equals 10^-3 N/m, which is 1 mN/m. The two numbers are therefore identical: 72.8 dyn/cm is 72.8 mN/m. Going to N/cm, a unit that appears in structural loads, 1 N/cm equals 100 N/m, so 72.8 mN/m is 0.000728 N/cm. Laboratories and industries still quote tension in dyn/cm, and coating makers print it on test inks, so a table with both columns is just one column printed twice. The conversion to N/m divides by 1000.
Values for common liquids
At about 20 degrees Celsius, ethanol has a surface tension near 22 mN/m, acetone about 23, and olive oil about 32. Water is 72.8 mN/m, glycerol about 63, and mercury about 485. A soap solution may be 25 to 30 mN/m, which is why bubbles form easily. These values are approximate and depend on temperature and purity. Surface tension falls as temperature rises: water is about 75.6 mN/m at 0 degrees Celsius and about 58.9 mN/m at 100 degrees Celsius. The trend means a hot dishwater wets surfaces more readily than cold, with a few mN/m of difference mattering for cleaning and coating.
Pressure inside a droplet
The Young-Laplace relation gives the excess pressure inside a spherical drop as ΔP = 2γ/r. A water droplet of radius 1 mm has ΔP = 2 × 0.0728 / 0.001 = 145.6 Pa. A drop of radius 1 µm has 145.6 kPa, about 1.4 atmospheres, which shows why tiny droplets are held at high internal pressure and evaporate more readily. A soap bubble has two surfaces, so ΔP = 4γ/r, and a bubble of 1 cm radius with γ = 0.025 N/m has 10 Pa of excess pressure. These formulas have the surface tension in N/m, so a value in dyn/cm needs converting before it is used.
Capillary rise
In a narrow tube, a liquid that wets the wall rises to a height h = 2γ cos θ / (ρ g r). For water in a clean glass tube of radius 0.5 mm, with a contact angle of 0 degrees, γ = 0.0728 N/m, ρ = 1000 kg/m³ and g = 9.81 m/s², h = 2 × 0.0728 / (1000 × 9.81 × 0.0005) = 0.0297 m, or about 3 cm. Halving the radius doubles the height. The effect moves water through paper, soil and the fine channels of plants, and it is the reason a narrow glass tube makes a quick check of liquid properties. Mercury, which does not wet glass, is depressed instead of raised.
How surface tension is measured
The du Noüy ring method pulls a platinum ring through the surface and records the force at detachment, and the Wilhelmy plate method measures the force on a thin plate partly immersed in the liquid. The pendant drop method analyzes the shape of a hanging drop. Instruments report in mN/m, and many show dyn/cm as an option. Contamination matters: a trace of surfactant can reduce clean water from 72.8 to below 50 mN/m. Surface tension values for pure water are used to check a tensiometer, with 72.0 mN/m at 25 degrees Celsius a common check value. A reading far from it points to a dirty ring or contaminated water, and not to a unit problem. When a report lists 45 dyn/cm for a cleaning solution, that is 45 mN/m or 0.045 N/m, which is well below plain water and low enough to wet most metals.
Dyne levels in coating and printing
Printers and converters treat plastic films so that inks and adhesives stick. The film surface energy is described in the same units, and test inks with known tensions, for example 38 dyn/cm, show whether a film is receptive. Untreated polyethylene is around 31 mN/m, and corona treatment raises it to about 38 to 42. An ink wets the film when its own surface tension is lower than the surface energy of the film. Because dyn/cm equals mN/m, a data sheet that gives 40 dyn/cm and a standard in mN/m describe the same level, which is useful when specifications cross borders.
Surfactants and temperature
Adding a surfactant lowers surface tension until the critical micelle concentration is reached, above which the value levels off. Sodium dodecyl sulfate in water drops the tension to roughly 35 to 40 mN/m at that point. Temperature enters through the Eötvös relation, in which tension falls roughly linearly to zero at the critical point of the liquid. In practice this explains why heated cleaning baths wet surfaces better. The unit remains N/m throughout, and the prefixed form mN/m keeps the numbers in a convenient range of 20 to 80 for most liquids at room temperature.
Confusion with distributed load
A line load on a beam, such as the weight of a wall per meter of its length, has the unit N/m, the same as surface tension. So does the tension per width in a stretched membrane or fabric. The definitions differ. A surface tension of 0.0728 N/m is tiny compared with a distributed load of 5000 N/m on a floor beam, though both use one unit. A converter handles the unit only, so 72.8 mN/m becomes 0.0728 N/m or 0.000728 N/cm, and the reader supplies the physical meaning. Writing the interface, such as water to air, and the temperature next to the number prevents a table value from being applied in the wrong setting. Interfacial tension between two liquids, such as oil and water at about 20 to 50 mN/m depending on the oil, uses the same unit, and a value labeled only as tension may refer to that interface instead of the liquid to air surface.
Precision and checking
- Keep temperature, interface composition and source precision.
- Retain the length denominator with the force prefix.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Choose a unit definition
Newtons per meter (N/m)
Definition, reference values and linked conversions.
Millinewtons per meter (mN/m)
Definition, reference values and linked conversions.
Newtons per centimeter (N/cm)
Definition, reference values and linked conversions.
Use a working converter
- Surface tension converter
- Newtons per meter to Millinewtons per meter converter
- Millinewtons per meter to Newtons per meter converter
- Newtons per meter to Dynes per centimeter converter
- Dynes per centimeter to Newtons per meter converter
- Newtons per meter to Newtons per centimeter converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.