Measurement basis
A micrometer corresponds to 10^-6 meter in the reference definitions.
Definition conventions
The distance definitions are international. A light-year uses a 365.25-day Julian year, and the parsec follows the IAU angular definition with finite numerical precision.
Conversion method
Multiply µm by 10^-6 to read m. Keep the quantity linear when applying the factor.
Reference equivalent of µm
1 µm = approximately 0.000001 m.
Recorded scale factors: 0.000001 for µm; 1 for m.
Worked example
Known input: 10 µm. Reference equivalent: 0.00001 m. The return conversion gives approximately 10 µm.
The small meter reference result keeps the micro source scale explicit.
Common reference values
| Input (µm) | Reference equivalent (m) |
|---|---|
| 1 | 0.000001 |
| 5 | 0.000005 |
| 10 | 0.00001 |
| 25 | 0.000025 |
| 50 | 0.00005 |
| 100 | 0.0001 |
Compare one µm with other units
| Target unit | Equivalent of 1 µm | Definition guide |
|---|---|---|
| Metres (m) | 0.000001 | Read definition |
| Kilometres (km) | 1e-9 | Read definition |
| Centimetres (cm) | 0.0001 | Read definition |
| Millimetres (mm) | 0.001 | Read definition |
| Inches (in) | 0.0000393700787402 | Read definition |
| Feet (ft) | 0.00000328083989501 | Read definition |
| Yards (yd) | 0.00000109361329834 | Read definition |
| Miles (mi) | 6.21371192237e-10 | Read definition |
A micrometer as a length
One micrometer (µm) is 10⁻⁶ meter, one thousandth of a millimeter. The meter is the SI base unit of length, defined by the fixed speed of light in vacuum, 299,792,458 m/s, with the second fixed by the cesium frequency. A micrometer is therefore the distance light covers in about 3.34 femtoseconds. The scale suits objects between the limit of the unaided eye and the limit of optical microscopes: red blood cells measure around 7 to 8 µm across, many bacteria are 1 to 5 µm, and a human hair is roughly 50 to 100 µm thick. Optical wavelengths, from about 0.4 to 0.7 µm for visible light, and thermal infrared at 8 to 14 µm are also quoted in micrometers.
From micron to micrometer
The same length was long called the micron, with the symbol µ. The CGPM adopted the SI prefix micro in 1960, and in 1967 it withdrew the names micron and the symbol µ for the length, leaving micrometer as the correct term. NIST SP 811 recommends the micrometer and the symbol µm. The name also collides with the instrument called a micrometer or micrometer caliper, which measures thickness to about 0.01 mm or better. Context usually settles which is meant, but a drawing that lists a micrometer reading should say whether it means the unit or the instrument. When a drawing says 0.025 micron, convert it to 0.025 µm without losing the decimals. Older technical papers in semiconductors and filtration often use the older word.
Inch conversions and thickness callouts
The inch is defined as exactly 25.4 mm, so 1 inch equals 25,400 µm, and 1 mil (0.001 inch) equals exactly 25.4 µm. A coating of 0.003 inch is 76.2 µm. A copper layer of 35 µm, the nominal thickness of 1 oz/ft² copper on a printed circuit board, is 0.035 mm and about 1.378 mil. Paint, plating and anodizing thicknesses are routinely specified in µm, and in the United States in mils or microinches, where 1 µin = 0.0254 µm. Specifying 25 µm of nickel plating is equivalent to about 0.98 mil, so confirm which unit a drawing uses before ordering a process or interpreting a measurement.
Surface roughness and tolerances
Machined and ground surfaces are described with the arithmetic average roughness Ra in micrometers. A turned surface may have Ra of 1.6 to 3.2 µm, a ground surface near 0.4 µm, and a lapped surface 0.05 µm or lower. Dimensional tolerances follow international tolerance grades in ISO 286, which give permitted deviations in micrometers for a given nominal size and grade. For a 25 mm shaft in grade IT7 the tolerance zone is 21 µm wide, and the same size in IT6 allows 13 µm. Because tolerances are given in micrometers, a calculation that converts a nominal size to inches should keep enough decimals: 21 µm equals 0.00083 inch, or about 0.83 mil.
Particles and filtration
Air quality standards use micrometers to define particle classes. PM10 and PM2.5 refer to particles with aerodynamic diameter of 10 µm or smaller and 2.5 µm or smaller. The aerodynamic diameter is the size of a unit-density sphere that settles at the same speed, so it need not match a geometric measurement. Filters list ratings in micrometers, such as a 0.2 µm membrane commonly used in sterile filtration, and a 5 µm sediment cartridge in a household water system. Nominal ratings and absolute ratings differ, since a nominal rating allows some particles above the stated size to pass. The micrometer is also the common unit for pore size, fiber diameter and the thickness of films and membranes.
Optics, microelectronics and fabrication
Infrared optics, fiber optics and spectroscopy often use micrometers for wavelength. Telecommunications fiber carries light at 1.31 µm and 1.55 µm, and CO₂ lasers emit near 10.6 µm. In microfabrication, features once described in micrometers have moved into nanometers, with 1 µm = 1,000 nm, but micrometer dimensions are still standard for MEMS parts, printed electronics, microfluidic channels and many sensor structures. A microfluidic channel 100 µm wide and 50 µm deep has a cross section of 5,000 µm², which is 0.005 mm². Area and volume conversions need squared and cubed factors: 1 mm² is 10⁶ µm², and 1 mm³ is 10⁹ µm³. Using only the linear factor gives errors of 1,000 or more.
Converting micrometers on the site
The site lists Millimetres to micrometers, Centimetres to micrometers, Metres to micrometers, Kilometres to micrometers and Inches to micrometers, with factors of 1,000, 10,000, 1,000,000, 1,000,000,000 and 25,400 respectively. Using those, 0.25 mm equals 250 µm, 1.5 cm equals 15,000 µm, 0.002 m equals 2,000 µm and 0.0004 inch equals 10.16 µm. Going the other way, divide: 2.5 µm is 0.0025 mm, 0.00025 cm and 2.5 × 10⁻⁶ m. The Length converter provides value, from and to selections for related units. A unit conversion gives the same physical length in a different scale and does not alter a measurement uncertainty, which stays whatever the measuring instrument supports. A reading of 7.5 µm made with a microscope reticle graduated at 0.5 µm is known to the nearest 0.5 µm, whatever the length is later written as.
Notation and frequent mistakes
The symbol is µm, with a Greek mu or the micro sign and a lowercase m. Writing mm, which is a thousand times larger, is the most damaging slip, and the letter m alone is the meter. Using u in plain text, as in um, is common but can be mistaken for a typo. Microns written as µ without the m appear in older documents, and the bare symbol µ means the prefix, not a unit. Another confusion is between a length in micrometers and a measurement made with a micrometer instrument: a reading of 12.345 mm from the tool is 12,345 µm, which has five significant figures and no more precision than the instrument allows.
Length change from temperature in micrometers
Thermal expansion is usually small enough that micrometers are the natural unit. The linear coefficient of steel is about 12 × 10⁻⁶ per kelvin and that of aluminum about 23 × 10⁻⁶ per kelvin, so a 1 m steel rod warmed by 10 K grows by roughly 120 µm, and an aluminum rod of the same length grows by about 230 µm. A 100 mm aluminum part changed by 5 K moves 11.5 µm, which exceeds many machining tolerances. Metrology labs control temperature to within a fraction of a kelvin for this reason, and dimensional standards refer to a reference temperature of 20 °C, as in ISO 1. A drawing that lists a 10 µm tolerance on a part that will be measured warm from a machine is incomplete without a stated measurement temperature.
Precision and checking
- Retain measurement resolution.
- Keep the micro symbol rather than a plain m label.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Length converter
- Micrometers to Millimetres converter
- Micrometers to Centimetres converter
- Micrometers to Metres converter
- Micrometers to Kilometres converter
- Micrometers to Inches converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.
Sources
- NIST / BIPM: NIST: unit conversion factors ↗ · 2026-10-08
- IAU: Astronomical distance conventions ↗ · 2026-10-08