IMAGE, AUDIO AND COORDINATE WORKSHEETS

Combining supplied additive powers before taking logarithms

Two equal sources do not add their decibel levels. Add the powers first, then take the logarithm. This guide shows the method with several source counts.

Why displayed levels cannot be added

A decibel level is a logarithm, and the logarithm of a sum is not the sum of logarithms. Writing two levels of 0 dB side by side and adding them gives 0, which would claim that two sources are no louder than one. When the powers themselves add, the combined power is the sum of the individual powers, and the level is computed from that sum. The audio dB calculator performs the final step, converting a power and a reference into a level. The addition of the powers is yours to do before you enter anything. Skipping that step is the most common error in this area, and it always understates the result.

Two sources at a level of zero

Two supplied powers of 1 each, against a reference of 1, have levels of 0 dB. Their total power is 2, and the level of 2 against 1 is 10 × log10(2), about 3.0103 dB. Doubling the power adds about 3 dB regardless of the starting level. Four equal powers total 4, giving about 6.0206 dB, and ten equal powers total 10, giving exactly 10 dB. The gain from adding identical sources therefore follows 10 × log10(n), where n is the count. Each doubling of the number of sources adds about 3.01 dB, and each tenfold increase adds 10 dB.

Unequal powers

Adding a weak source to a strong one changes the total only slightly. Take powers of 10 and 1 against a reference of 1, which have levels of 10 dB and 0 dB. The total power is 11 and its level is 10 × log10(11), about 10.4139 dB. The weaker source raises the level by only about 0.41 dB. A source 10 dB below another contributes a tenth of its power, which is why a quiet component in a noisy mix rarely changes the total. The rule of thumb is that a source more than about 10 dB below the strongest adds under half a decibel.

Levels with a real reference

Machinery noise is often described by sound power level, which uses a reference of one picowatt, or 10⁻¹² watt. Suppose, as an illustration, two machines each radiate 1 microwatt. Each has a level of 10 × log10(10⁻⁶ / 10⁻¹²) = 60 dB. Their total power is 2 microwatts, and the level is about 63.0103 dB, again 3.01 dB above one machine. If instead the first level is 90 dB and the second is 80 dB, convert them to relative powers of 10⁹ and 10⁸. Their sum is 1.1 × 10⁹, giving about 90.4139 dB. The same steps work with any reference, as long as it is the same for both levels.

Converting levels back to powers

Often you start with levels and need powers. The conversion is power = reference × 10^(level / 10). A level of 20 dB against a reference of 1 is a power of 100, and a level of 3 dB is about 1.995, close to double. After converting each level, add the powers, then convert the total back with the calculator. A shortcut applies for two equal levels, where the total is the level plus 3.01 dB, and for a difference larger than 10 dB, where the total is only slightly above the larger level. Keeping those shortcuts in mind lets you check a calculated total by eye.

The additive assumption

The method assumes that the powers add, which holds for independent sources whose contributions do not interfere. Many noise sources behave this way over time-averaged measurements. Coherent signals do not. Two identical sine waves in phase combine in amplitude, so the combined power is four times that of one rather than two times, and out of phase they can cancel. Acoustic fields in rooms, sound near reflective surfaces and fields from antenna arrays follow their own rules. The worked example is an arithmetic illustration under a stated additive model, and a real situation needs a justification that this model applies.

Subtracting a background level

The reverse operation appears when removing background noise from a measurement. If a total of 10 dB and a background of 0 dB are measured against the same reference, the source power is 10 minus 1, which is 9, and its level is about 9.542 dB. Subtraction works on powers and not on levels. The method needs the background and the total measured under the same conditions, and it becomes unreliable when the two are within a couple of decibels of each other, because the difference of two nearly equal powers is sensitive to measurement error.

Common slips

The usual mistakes are adding levels directly, averaging levels when a total is wanted, mixing references between sources, and applying the power formula to voltage or pressure ratios. A sign that something went wrong is a combined level lower than the loudest individual level, which cannot happen when powers are added. A further check is the count rule: ten identical sources must come out exactly 10 dB above one, and a hundred must come out 20 dB above. When a calculation fails those tests, go back to the powers and confirm each was converted with the same reference. Also confirm that every power was entered in the same unit as the reference, since a watt entered against a milliwatt reference shifts the whole answer by 30 dB and still looks like a plausible number.

Scope of this worksheet

The page demonstrates arithmetic on supplied powers under an additive model. It does not establish how coherent signals, fields or measured sound sources combine in a given setting, it does not apply frequency weighting, and it does not check compliance with any limit. Those questions need a justified physical model and the relevant standard. A useful habit is to write the model assumption beside the result, for example independent sources, powers added, one shared reference. If a colleague changes any of those three statements, the arithmetic changes with it. The calculator will return a level for any positive power, so the responsibility for choosing a sensible combination rule rests with the person entering the numbers. When the sources are few and well separated in level, the quick rules of thumb above are usually enough to confirm the calculated total.

Reproduce the checks

One supplied power

Open the Audio Db Calculator and enter:

Measured power
1
Reference power
1

Expected output:

Power-ratio level difference

0

Each individual ratio is one.

Additive total power

Open the Audio Db Calculator and enter:

Measured power
2
Reference power
1

Expected output:

Power-ratio level difference

3.010299956639812

The logarithm is applied after adding the supplied powers.

References and implementation scope

The examples describe the behavior of the linked Computandum tools. A successful local check does not establish that another application accepts the same format or applies the same limits.