Vacuum gauges made for the US market often read in torr or millitorr, while many journals and European instrument makers use pascals and their prefixed forms. A process engineer who runs a coating or etching step at a setpoint in millitorr and must write the method in SI units needs the conversion. This page multiplies torr by 133.3224 and by 1,000 and returns millipascals. It serves lab technicians, students writing methods sections and anyone transcribing a recipe between two sources. The numbers it returns are in the thousands or millions for ordinary process pressures, which is a readable range for a vacuum log. A change of 1 mTorr moves the reading by 133.3 mPa, so the unit is fine enough to show small drifts without needing decimals.

Definition and the millipascal step

The torr is 1/760 of a standard atmosphere, which is 101,325 Pa, so one torr is 133.3223684 Pa. A millipascal is one thousandth of a pascal, so one torr is 133,322.3684 mPa. The page formula is mPa = Torr × 133322.368421. NIST SP 811 lists the torr and its pascal equivalent, and the milli prefix is from the SI Brochure. The torr itself is not an SI unit, but it is accepted in practice for vacuum and blood pressure work and appears in the tables of NIST SP 811. The factor is a defined ratio, so the result is limited only by the digits you enter. By hand, multiply by 133.322 and then by 1,000. For a quick estimate, one torr is about 133,000 mPa. The same approach gives 0.5 Torr as about 66,661 mPa and 2 Torr as 266,645 mPa.

Ten torr in millipascals

The default 10 Torr returns about 1,333,223.684 mPa. That is 1,333.22 Pa, or about 13.3 mbar, a rough vacuum such as the one reached by a modest pump in the first minutes of pumping down. In millipascals the number has seven digits, and in pascals it has four, so the unit choice changes how a log reads. If you see 13,332 instead, you converted 0.1 Torr. The default also makes a good test value for code that handles pressure units: the leading digits 1.3332 are common to all the torr pages.

A 5 mTorr process setpoint

Plasma and sputtering processes often run at a few millitorr. A setpoint of 5 mTorr is 0.005 Torr, which converts to about 666.6 mPa, or 0.6666 Pa. A 100 mTorr setpoint is 0.1 Torr, about 13,332 mPa, or 13.33 Pa. A 1 mTorr step is 133.32 mPa. These are typical orders of magnitude, and the correct value for any process comes from its recipe. Entering the torr value on the page, and not the millitorr one, is the point to watch: 5 mTorr must be typed as 0.005. A factor of 1,000 error in the setpoint changes the process entirely. Recipes copied between tools often carry the unit in a separate field, so confirm that field as well as the number.

mTorr, mT and mPa on one datasheet

The symbols for millitorr, millitesla and millipascal can look alike, and datasheets sometimes abbreviate millitorr as mT, which also stands for a magnetic field unit. In a sputtering system, where magnets and pressure both appear in one document, that is a real risk. This page uses the full names and the symbol mPa for millipascals. Always spell out a unit where an abbreviation could be read in two ways, and keep the unit next to the number in notes and logs. A capital M for mega and a lowercase m for milli differ by a factor of 10^9, and a mixed-up prefix produces results that are not just wrong but impossible.

From millipascals back to torr

Select millipascals as the source and torr as the target to reverse the conversion. A pressure of 1,000 mPa, which is 1 Pa, comes to about 0.0075006 Torr, or 7.5 millitorr. A pressure of 1 mPa is about 7.5 × 10^-6 Torr, or 7.5 microtorr. High-vacuum gauges report values in this range. When a paper gives a base pressure in millipascals and your gauge reads in torr, this is the step that lets you compare the two without a lookup table. Keep the exponent when you copy the result, since small values appear in scientific notation. High-vacuum literature often reports such values in micropascals or in 10^-6 Torr instead, and the sibling pages cover those targets.

Gauges and what they can resolve

Different gauges cover different ranges. Capacitance manometers are used for accurate readings in the millitorr range and above, while ionization gauges cover much lower pressures, and each has its own accuracy statement. The conversion cannot improve the reading, and writing 666.6118 mPa for a 5 mTorr setpoint implies a precision that the gauge probably lacks. Round to the digits the instrument supports, such as 667 mPa, and keep the original reading in the log. Many vacuum controllers display three or four digits, which is all the information the setpoint contains. The conversion factor is accurate to many digits, so an unexpected difference between two records usually comes from a different input or a rounding choice.

Torr and conventional mmHg

Conventional millimeters of mercury equal 133.322387415 Pa, and the torr is 133.3223684 Pa. They differ by about 1.4 parts in ten million, which no vacuum gauge can resolve, so people use the two names interchangeably. The page treats them as separate options, and the label of your source should be kept in formal documents. A recipe that lists pressure in mmHg can be entered as torr for practical purposes, though a method meant for others should state which unit the original gauge used. A one-line note in the method, such as setpoint given in torr as read on the gauge, answers the question before a reader asks it.

Absolute reference

Vacuum pressures are absolute, measured from zero pressure, and the conversion keeps that reference. Gauge readings relative to the atmosphere need to be turned into absolute values first, by adding the local atmospheric pressure of about 760 Torr at sea level. A reading of minus 700 Torr on a gauge that measures relative to the atmosphere is about 60 Torr absolute, which is 7,999,342 mPa. Check the reference of a gauge in its manual before you convert, because a mix-up here changes the answer by far more than rounding.