Two ways of writing the same barometer

Older barometers and almanacs in many countries give pressure in millimeters of mercury, while weather maps, marine charts and most modern instruments use millibars. The page converts between them, so a 1950s textbook reading, a ship's log or a laboratory manual can be compared with a current forecast. The default is 10 mmHg, which becomes 13.3322387415 mbar. The millibar is one thousandth of a bar and exactly 100 pascals, which means a millibar is numerically identical to a hectopascal. Many weather services now label the same unit hectopascal, but millibar remains in common use in vacuum work and in the US marine and weather community. The conversion uses the conventional mercury definition at 0 °C, and the factor, 1.33322387415, is the same number as the pascals in one millimeter of mercury divided by 100.

The factor and quick mental arithmetic

To convert, multiply by 1.33322387415. Ten mmHg is 13.3322 mbar, and 15 mmHg is 19.9984 mbar, nearly 20. A convenient shortcut is that 3 mmHg is almost exactly 4 mbar, since 3 times 1.3332 is 3.9997. Another is that 750 mmHg is about 1,000 mbar. In reverse, a millibar value times 0.75 gives mmHg, accurate to about 0.01 percent. Using the shortcut, 1,013 mbar is 759.75 mmHg, and the exact figure is 759.8. This is good enough for checking a reading by eye and for catching a misplaced decimal. Because the relationship is a straight proportion with no offset, there is no need to adjust for zero. Zero millibar is zero mmHg, and the ratio holds through the whole range from hard vacuum to hurricane lows.

Standard pressure and the 760 line

The anchor point for atmospheric work is 760 mmHg, the height of the mercury column that standard pressure supports. In millibars, 760 mmHg converts to 1,013.2501 mbar, effectively the 1,013.25 mbar of the standard atmosphere. The tiny difference, about 0.0001 mbar, appears because the standard atmosphere is defined in pascals as 101,325 while the conventional mmHg value is 133.322387415 pascals, and 760 times that is 101,325.0144 pascals. Barometer scales are often marked with both units, with 760 mmHg lined up against 1,013 mbar. Typical sea-level readings in the real atmosphere range from about 980 to 1,040 mbar, which is roughly 735 to 780 mmHg. A reading far outside that band at sea level is either an extreme storm, an instrument error or a pressure that has not been reduced to sea level.

A weather example with extreme lows

The lowest sea-level pressure ever measured in a tropical cyclone, 870 millibars in Typhoon Tip in October 1979, converts to 652.55 mmHg. A strong hurricane with a central pressure of 900 mbar corresponds to 675.06 mmHg. Both are far below the 760 mmHg reference, and for Typhoon Tip the mercury column would sink more than 100 mm to match. In everyday use, the drop of a barometer by 3 to 4 mbar in three hours, which is 2.3 to 3 mmHg, is a common marker of a falling-pressure trend that forecasters watch. Converting the other direction, a mercury barometer reading of 745 mmHg translates to 993.25 mbar, a moderate low. The converter lets you check any of these numbers, and the reverse conversion handles the case where you start with a map value and need the mercury height.

Vacuum technology and the millibar

In vacuum work, millibar is a standard unit in European catalogs. A rotary vane pump might list an ultimate pressure of 0.001 mbar, and a diaphragm pump might reach about 1 to 10 mbar. In mmHg, 1 mbar is 0.750062 and 10 mbar is 7.50062. Rough vacuum is conventionally the range from atmospheric pressure down to about 1 mbar, which is about 0.75 mmHg. A rotary evaporator running at 25 mmHg is working at 33.33 mbar, a common setting for removing solvents such as ethyl acetate at moderate bath temperatures. When procedure sheets mix units, the converter prevents errors: a method that says 30 mmHg means 40 mbar, and setting a controller to 30 mbar would produce a stronger vacuum than intended. Check the setting against the solvent's vapor pressure curve in whichever unit the curve uses.

Aviation and altimeter conversions

Altimeter settings in most of the world are reported in hectopascals, which are numerically the same as millibars, while the United States and Canada use inches of mercury. Older European instruments and some historical weather logs use millimeters of mercury. A pilot or dispatcher moving among sources sometimes has to translate a value like 760 mmHg, which is the standard setting, into 1,013 on a hectopascal altimeter. Remember that one millibar corresponds to about 8 meters or 27 feet of altitude near sea level, so an error of 10 mbar in a setting produces about 80 meters, or about 270 feet, of altitude error. The converter gives the numeric translation. It does not replace the official altimeter setting for a given airport, which comes from the current weather report and applies to the local area.

Millibar, hectopascal and bar

Three names cover related units. One bar is 100,000 pascals. One millibar is 0.001 bar and 100 pascals. One hectopascal is also 100 pascals, so the numbers match exactly. The bar is not an SI unit, and the millibar was the standard meteorological unit for much of the twentieth century. The hectopascal label follows SI usage, since hecto is a standard prefix and the pascal is the SI unit. When a document shows hPa, you can treat it as mbar and use this converter directly. In scientific papers, kPa is also common, with 1 kPa equal to 10 mbar, so 760 mmHg is 101.325 kPa. A practical habit is to write the unit next to every number in a log, because a bare 760 or 1,013 is only recognizable to someone who already knows the standard pressure. Data loggers and spreadsheets that import weather files often drop the unit label, and a column of values near 1,000 is millibars while a column near 760 is millimeters of mercury. If the values in a column sit near 30, they are inches of mercury, and if they sit near 101, they are kilopascals. Recognizing the typical magnitude of each unit lets you spot a mislabeled column before any conversion is applied, and the converter then confirms the exact numbers.

Choosing precision

The converter returns many digits, but real mercury barometers resolve 0.1 mmHg at best, which is about 0.13 mbar. A reading of 756.3 mmHg therefore converts to 1,008.3 mbar, and quoting it as 1,008.27 adds nothing. Digital barometers in weather stations typically resolve 0.1 mbar. When two readings are compared, keep the same number of decimal places for each. If you are logging data in a spreadsheet, store the original measured value and its unit in one column and the converted value in another, so the source number is never lost. This also makes it easier to apply a different factor later if a calibration certificate specifies a slightly different reference. The factor used here is the conventional one from NIST, and it is what most published tables use.

What this page leaves out

The conversion is a unit change. It does not reduce a station pressure to sea level, correct a mercury barometer for temperature and gravity, or decide a vacuum setting for a process. It also takes no position on whether a pressure is a forecast sign, a safe working condition or a valid calibration. A mercury barometer that has not been corrected can read several tenths of a millimeter off, which is a meaningful fraction of a millibar. For forecasts, rely on the official weather service. For vacuum processes, follow the procedure for the equipment and the chemicals involved. For instrument calibration, use the certificate and the reference conditions it specifies. This page expresses a value you already trust in the other unit, using the factor published in the NIST SI conversion tables.

Pressure and the boiling point of water

Pressure conversions matter in cooking at altitude, distillation and steam work, where the boiling temperature follows the surrounding pressure. Water boils at 100 °C when the pressure is the standard 760 mmHg, which is 1,013.25 mbar. At 80 °C the saturation pressure of water is about 355 mmHg, or 474 mbar, so a vessel pulled down to that level boils at 80 °C. At room temperature near 20 °C, water vapor pressure is about 17.5 mmHg, or 23.4 mbar, and that sets the limit for how far a water-filled vacuum system can be pumped before the liquid itself starts to boil away. Vapor pressure tables are published in kPa, mmHg or mbar depending on the source, and this converter moves between them. The values quoted here are approximate textbook figures, and a specific process should use its own reference table.

Common mmHg values in millibars

A short list of conversions can serve as a ruler. One mmHg is 1.3332 mbar, 5 mmHg is 6.6661 mbar, 10 mmHg is 13.3322 mbar, 50 mmHg is 66.6612 mbar, 100 mmHg is 133.3224 mbar and 500 mmHg is 666.6119 mbar. Each is the mmHg value times the factor 1.33322387415, shown to four decimals. The list also shows how the unit steps up. Every 3 mmHg adds almost exactly 4 mbar, and every 750 mmHg adds almost exactly 1,000 mbar. A good use for the list is checking spreadsheet formulas. Fill a column with the mmHg numbers above, apply your formula, and compare it with these reference values. Any difference larger than the last digit points to a typing error in the factor.